Thijs A. Stockmans

Thijs A. Stockmans

Auto-generated profile, based on publicly available information

Thijs A. Stockmans

Leiden Observatory, Leiden University, P.O. Box 9513, 2300 RA Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in Applied Optics
Verified
Journal Article
Closed access
NHNathan Hagen
Nathan Hagen
TSThijs Stockmans
Thijs Stockmans
YOYukitoshi Otani
Yukitoshi Otani
PBPrathan Buranasiri
Prathan Buranasiri
We review Fourier-domain methods for demosaicking Bayer-filter color cameras and monochrome polarization cameras, and then generalize the approach for the quad-Bayer-filter mosaic and for color-polarization cameras. For each of these four mosaic filter types, we provide theoretical expressions for the sampling functions, the Fourier-domain channels, and the linear combination of reconstructed channels (the demosaicking algorithm) needed to estimate the input (presampled) image. A useful advantage of the Fourier-domain approach is that it provides a direct means of visualizing and quantifying when aliasing is likely or unlikely to be present. For the Bayer and quad-Bayer-filter types, we provide simulated images, while for the polarization camera types we provide experimental images and videos to illustrate the algorithm and analyze crosstalk error.

13 September 2023 in Applied Optics
Verified
Journal Article
Closed access
TST. A. Stockmans
T. A. Stockmans
FSFrans Snik
Frans Snik
MEMarco Esposito
Marco Esposito
CDChris van Dijk
Chris van Dijk
CKChristoph Keller
Christoph Keller
Classic designs of hyperspectral instrumentation densely sample the spatial and spectral information of the scene of interest. Data may be compressed after the acquisition. In this paper, we introduce a framework for the design of an optimized, micropatterned snapshot hyperspectral imager that acquires an optimized subset of the spatial and spectral information in the scene. The data is thereby already compressed at the sensor level but can be restored to the full hyperspectral data cube by the jointly optimized reconstructor. This framework is implemented with TensorFlow and makes use of its automatic differentiation for the joint optimization of the layout of the micropatterned filter array as well as the reconstructor. We explore the achievable compression ratio for different numbers of filter passbands, number of scanning frames, and filter layouts using data collected by the Hyperscout instrument. We show resulting instrument designs that take snapshot measurements without losing significant information while reducing the data volume, acquisition time, or detector space by a factor of 40 as compared to classic, dense sampling. The joint optimization of a compressive hyperspectral imager design and the accompanying reconstructor provides an avenue to substantially reduce the data volume from hyperspectral imagers.

21 October 2026
Verified
Other
Open access
PDF file
Gaël CessateurGaël Cessateur
Gaël Cessateur
JLJean Lilensten
Jean Lilensten
HLHervé Lamy
Hervé Lamy
LBLéo Bosse
Léo Bosse
MJMagnar G. Johnsen
Magnar G. Johnsen
FSFrans Snik
Frans Snik
We present first-light observations of auroral imaging polarimetry with the Polaribotn camera, a monochrome micropolarizer-based instrument equipped with narrowband filtering at the O(1S) 557.7 nm green line. The instrument was operated simultaneously with the Corbel Cru polarimeter during a campaign in Skibotn, Norway, allowing a direct comparison with the existing narrow-field reference framework. The common field of view was identified empirically from the intensity time series, and the Polaribotn measurements show good agreement with Corbel Cru in both degree and angle of linear polarization. Extending the analysis to 63 regions of interest across the full image reveals that DoLP and AoLP do not respond in the same way to auroral structures: DoLP decreases in the brightest arc regions, whereas AoLP often remains coherent over a large fraction of the field of view. The corresponding (q,u) analysis points to a strong scene-wide polarization component with local intensity-dependent perturbations. Although the present dataset does not yet allow a definitive interpretation of the physical origin of the polarization, it demonstrates that auroral imaging polarimetry is feasible and provides spatial information not accessible to previous narrow-field instruments.

9 October 2026
Verified
Other
Open access
PDF file
Gaël CessateurGaël Cessateur
Gaël Cessateur
JLJean Lilensten
Jean Lilensten
HLHervé Lamy
Hervé Lamy
LBLéo Bosse
Léo Bosse
MJMagnar G. Johnsen
Magnar G. Johnsen
FSFrans Snik
Frans Snik
We present first-light observations of auroral imaging polarimetry with the Polaribotn camera, a monochrome micropolarizer-based instrument equipped with narrowband filtering at the O(1S) 557.7 nm green line. The instrument was operated simultaneously with the Corbel Cru polarimeter during a campaign in Skibotn, Norway, allowing a direct comparison with the existing narrow-field reference framework. The common field of view was identified empirically from the intensity time series, and the Polaribotn measurements show good agreement with Corbel Cru in both degree and angle of linear polarization. Extending the analysis to 63 regions of interest across the full image reveals that DoLP and AoLP do not respond in the same way to auroral structures: DoLP decreases in the brightest arc regions, whereas AoLP often remains coherent over a large fraction of the field of view. The corresponding (q,u) analysis points to a strong scene-wide polarization component with local intensity-dependent perturbations. Although the present dataset does not yet allow a definitive interpretation of the physical origin of the polarization, it demonstrates that auroral imaging polarimetry is feasible and provides spatial information not accessible to previous narrow-field instruments.

9 October 2026
Verified
Other
Open access
PDF file
Gaël CessateurGaël Cessateur
Gaël Cessateur
JLJean Lilensten
Jean Lilensten
HLHervé Lamy
Hervé Lamy
LBLéo Bosse
Léo Bosse
MJMagnar G. Johnsen
Magnar G. Johnsen
FSFrans Snik
Frans Snik
We present first-light observations of auroral imaging polarimetry with the Polaribotn camera, a monochrome micropolarizer-based instrument equipped with narrowband filtering at the O(1S) 557.7 nm green line. The instrument was operated simultaneously with the Corbel Cru polarimeter during a campaign in Skibotn, Norway, allowing a direct comparison with the existing narrow-field reference framework. The common field of view was identified empirically from the intensity time series, and the Polaribotn measurements show good agreement with Corbel Cru in both degree and angle of linear polarization. Extending the analysis to 63 regions of interest across the full image reveals that DoLP and AoLP do not respond in the same way to auroral structures: DoLP decreases in the brightest arc regions, whereas AoLP often remains coherent over a large fraction of the field of view. The corresponding (q,u) analysis points to a strong scene-wide polarization component with local intensity-dependent perturbations. Although the present dataset does not yet allow a definitive interpretation of the physical origin of the polarization, it demonstrates that auroral imaging polarimetry is feasible and provides spatial information not accessible to previous narrow-field instruments.

9 April 2025 in arXiv
Verified
Preprint
Open access
PDF file
TST. A. Stockmans
T. A. Stockmans
FSF. Snik
F. Snik
JSJ. M. Smit
J. M. Smit
JRJ. H. H. Rietjens
J. H. H. Rietjens
MEM. Esposito
M. Esposito
CKC. U. Keller
C. U. Keller
Modern detector manufacturing allows spectral and polarimetric filters to be directly integrated on top of separate detector pixels. This enables the creation of CubeSat-sized spectro-polarimetric instruments that are not much larger than the detector and a lens. Redundancy inherent to the observed scene, offers the opportunity for sparse sampling in the form of not scanning all filters at every location. However, when there are fewer pushbroom steps than filters, data are missing in the resulting data cube. The missing, largely redundant data can be filled in with interpolation methods, often called demosaicers. The choice of filters and their precise layout influences the performance of the instrument after the demosaicing process. In these proceedings we describe a part of a design toolbox for both the filter layout and the optimum parameters for the reconstruction to a full spectro-polarimetric data cube. The design tool is based on training a (neural) network and jointly updating the values of the filters and demosaicer. We optimized a filter layout by training on spectro-polarimetric remote observations of the Earth acquired by SPEX airborne. This optimised filter layout could reconstruct a validation scene from five overlapping snapshots (pushbroom steps), which would take 109 pushbroom steps when measuring with a classical layout and no reconstruction.