1 August 2021 in International Journal of Cardiology
1 July 2020 in The American Journal of Cardiology
4 September 2020 in Catheterization and Cardiovascular Interventions
VIValent M. P. Intan‐Goey
+3
Objectives: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis.Background: Differences in clinical outcomes between the latest‐generation balloon‐expandable S3 and self‐expanding NEO in a “real‐world transfemoral TAVI population” are still unclear.Methods: We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics.Results: A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW‐adjusted OR: 0.35 [95% CI: 0.12–1.18], and early safety: IPTW‐adjusted OR: 0.51 [95% CI: 0.19–1.38]). Six‐months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS).Conclusions: Device success and clinical safety outcomes were comparable for both valves. Up to 6‐months follow‐up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.
2 January 2019 in Catheterization and Cardiovascular Interventions
Background: Polymer‐free amphilimus‐eluting stents (PF‐AES) represent a novel elution‐technology in coronary stenting. We aimed to assess 1‐year clinical outcomes of PF‐AES as compared to latest‐generation permanent polymer zotarolimus‐eluting stents (PP‐ZES) in a real‐world all‐comers setting.Methods: A prospective registry of patients treated with either PF‐AES or PP‐ZES between 2014 and 2016 was conducted. The primary outcome was defined as major adverse cardiac and cerebrovascular events (MACCE), and the secondary outcome was defined as target‐lesion failure (TLF) at 1 year. To account for measured confounders, a propensity‐score adjusted Cox proportional‐hazard model was built to evaluate clinical outcomes.Results: A total of 734 consecutive patients with 1,269 DES implantations were enrolled. The population was characterized by 28% diabetes, 24% ST‐segment elevation myocardial infarction, and a high number of complex lesions (69%). The rate of MACCE was 11.5% for PF‐AES and 13.6% for PP‐ZES, plog‐rank = 0.11. TLF was numerically lower in PF‐AES as compared to PP‐ZES (5.4 vs. 6.1%, plog‐rank = 0.68). After propensity‐score adjustment, PF‐AES showed a trend toward a lower rate of MACCE and a favorable rate of TLF as compared to PP‐ZES (HR 0.70; 95%CI 0.45 to 1.10, P = 0.12; and HR 0.88; 95%CI 0.47 to 1.65, P = 0.68, respectively). Rates of definite ST were low (0.8 vs. 0.3%, plog‐rank = 0.62).Conclusions: Our study suggests that implantation of PF‐AES was safe and effective in real‐world patients, with low‐rates of MACCE and TLF at 1 year. Our data needs to be confirmed by a large trial to evaluate the clinical outcomes of this novel polymer‐free, eluting‐technology used in PF‐AES.
19 November 2020 in Catheterization and Cardiovascular Interventions