Kendall D. Hughey

Kendall D. Hughey

Auto-generated profile, based on publicly available information

Kendall D. Hughey

Department of Chemistry, University of Tennessee, Knoxville, Tennessee 37996, United States

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2020 in Inorganic Chemistry
Verified
Journal Article
Closed access
ACAmanda Clune
Amanda Clune
NHNathan Harms
Nathan Harms
KOKenneth R. O’nEal
Kenneth R. O’nEal
KHKendall Hughey
Kendall Hughey
KSKevin A. Smith
Kevin A. Smith
JMJanice Musfeldt
Janice Musfeldt


27 April 2021 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
TJTimothy J. Johnson
Timothy J. Johnson
KHKendall D. Hughey
Kendall D. Hughey
TBThomas A. Blake
Thomas A. Blake
SSSteven W. Sharpe
Steven W. Sharpe
TMTanya. L. Myers
Tanya. L. Myers
RSRobert L. Sams
Robert L. Sams

3 February 2020 in Inorganic Chemistry
Verified
Journal Article
Closed access
KHKendall D. Hughey
Kendall D. Hughey
NHNathan C. Harms
Nathan C. Harms
KOKenneth R. O’nEal
Kenneth R. O’nEal
ACAmanda J. Clune
Amanda J. Clune
JMJeffrey C. Monroe
Jeffrey C. Monroe
JMJanice Musfeldt
Janice Musfeldt

25 February 2024 in Applied Spectroscopy
Verified
Journal Article
Closed access
BFBrenda M. Forland
Brenda M. Forland
KHKendall D. Hughey
Kendall D. Hughey
MWMichael J. Wilhelm
Michael J. Wilhelm
OWOlivia N. Williams
Olivia N. Williams
BCBenjamin F. Cappello
Benjamin F. Cappello
TJTimothy J. Johnson
Timothy J. Johnson
Due to a legacy originating in the limited capability of early computers, the spectroscopic resolution used in Fourier transform infrared spectroscopy and other systems has largely been implemented using only powers of two for more than 50 years. In this study, we investigate debunking the spectroscopic lore of, e.g., using only 2, 4, 8, or 16 cm −1 resolution and determine the optimal resolution in terms of both (i) a desired signal-to-noise ratio and (ii) efficient use of acquisition time. The study is facilitated by the availability of solids and liquids reference spectral data recorded at 2.0 cm −1 resolution and is based on an examination in the 4000–400 cm −1 range of 61 liquids and 70 solids spectra, with a total analysis of 4237 peaks, each of which was also examined for being singlet/multiplet in nature. Of the 1765 liquid bands examined, only 27 had widths <5 cm −1 . Of the 2472 solid bands examined, only 39 peaks have widths <5 cm −1 . For both the liquid and solid bands, a skewed distribution of peak widths was observed: For liquids, the mean peak width was 24.7 cm −1 but the median peak width was 13.7 cm −1 , and, similarly, for solids, the mean peak width was 22.2 cm −1 but the median peak width was 11.2 cm −1 . While recognizing other studies may differ in scope and limiting the analysis to only room temperature data, we have found that a resolution to resolve 95% of all bands is 5.7 cm −1 for liquids and 5.3 cm −1 for solids; such a resolution would capture the native linewidth (not accounting for instrumental broadening) for 95% of all the solids and liquid bands, respectively. After decades of measuring liquids and solids at 4, 8, or 16 cm −1 resolution, we suggest that, when accounting only for intrinsic linewidths, an optimized resolution of 6.0 cm −1 will capture 91% of all condensed-phase bands, i.e., broadening of only 9% of the narrowest of bands, but yielding a large gain in signal-to-noise with minimal loss of specificity.

25 April 2023 in Applied Spectroscopy
Verified
Journal Article
Closed access
CTChristopher J. Thompson
Christopher J. Thompson
NGNeal B. Gallagher
Neal B. Gallagher
KHKendall D. Hughey
Kendall D. Hughey
MDMegan K. Dunlap
Megan K. Dunlap
TMTanya L. Myers
Tanya L. Myers
TJTimothy J. Johnson
Timothy J. Johnson
A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.