Elwy Eissa El-Kholy

Elwy Eissa El-Kholy

Auto-generated profile, based on publicly available information

Elwy Eissa El-Kholy

Department of Electrical Engineering, Faculty of Engineering, Menoufia University, Menoufia, Egypt

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MSMahmoud A. Soliman
Mahmoud A. Soliman
Hany M. HasanienHany M. Hasanien
Hany M. Hasanien
HAHaitham Z. Azazi
Haitham Z. Azazi
EEE. E. El-Kholy
E. E. El-Kholy
SMSabry A. Mahmoud
Sabry A. Mahmoud
Wind power installations are rapidly increasing worldwide, leading to a huge level of permeation into electricity supply networks. Enormous efforts are spent to improve the performance of the wind turbine generator systems. This paper proposes a novel adaptive fuzzy logic control strategy for performance improvement of a grid-tied wind generator system. The variable-speed wind turbine driven permanent-magnet synchronous generator is tied to the network by a full-capacity power converter. A cascaded adaptive fuzzy logic control strategy is proposed as the control methodology for the generator- and the grid-side converter/inverter. The adaptive technique depends on continuous mixed p-norm algorithm, which on-line updates the scaling factors of the fuzzy logic controllers (FLCs) at a high convergence speed. For the sake of preciseness, real wind speed data measured in Zaafarana wind farm, Egypt, are considered in the analyses. The effectiveness of the proposed adaptive FLC is compared to that achieved using particle swarm optimization algorithm-based an optimal proportional-integral controller, considering severe grid disturbances. Extensive simulation analyses, which are done using MATLAB/Simulink, are presented to validate the efficiency of the adaptive fuzzy logic control strategy.

22 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
ARAmir Raouf
Amir Raouf
Kotb Basem TawfiqKotb Basem Tawfiq
Kotb Basem Tawfiq
EEElsayed Tag Eldin
Elsayed Tag Eldin
HYHossam Youssef
Hossam Youssef
EEElwy E. El-Kholy
Elwy E. El-Kholy
Recently, controlling a wind energy conversion system (WECS) under fluctuating wind speed and enhancing the quality of power delivered to the grid has been a demanding challenge for many researchers. This paper provides a comprehensive review of synchronous generator-based WECSs. This paper will investigate the growth of wind energy in Egypt and throughout the world, as well as the technological and financial significance of wind energy. The block diagram of a typical grid-connected WECS, power control techniques, characteristic power curve-based maximum power point tracking (MPPT), and MPPT techniques are also presented in this study. Moreover, this study compares different power converter topologies for grid-connected and independent WECSs that use a permanent magnet synchronous generator (PMSG).

25 August 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Kotb Basem TawfiqKotb Basem Tawfiq
Kotb Basem Tawfiq
Mohamed IbrahimMohamed Ibrahim
Mohamed Ibrahim
EEElwy Eissa El-Kholy
Elwy Eissa El-Kholy
PSPeter Sergeant
Peter Sergeant
Multiphase machines with a prime number of phases (five and seven) have shown better torque density than machines with other phase numbers. Unfortunately, these machines require a special stator design. Hence, this article proposes general rewinding techniques to obtain a five-phase winding from the existing standard three-phase stator frames. The proposed rewinding techniques are applied to construct a five-phase star-connected synchronous reluctance machine (SynRM 1) and a novel combined star-pentagon winding (SynRM 2). Simple mathematical formulations are introduced to compute the equivalent winding factor. The performance of five-phase SynRMs is analyzed using two-dimensional Ansys Maxwell transient simulations under the same copper volume for both healthy and faulty cases. SynRM 1 and 2 provide 6.56% and 13.35% higher torque compared to the three-phase SynRM at rated current and at optimal current angle. The torque ripple is decreased by 17% and 30%, respectively. Moreover, SynRM 1 and 2 offer a better performance at the faulty case; e.g., at one phase opened, the average torque of SynRM 1 and 2 is 82% and 108% higher compared to the three-phase SynRM. In addition, the torque ripple is reduced by about 63% and 81%. Finally, experimental results are done to validate the proposed winding techniques.

4 October 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Kotb Basem TawfiqKotb Basem Tawfiq
Kotb Basem Tawfiq
Mohamed IbrahimMohamed Ibrahim
Mohamed Ibrahim
EEE. E. El-Kholy
E. E. El-Kholy
PSPeter Sergeant
Peter Sergeant
This article compares the performance of an existing three-phase synchronous reluctance machine (SynRM) with an identical machine that is upgraded to a five-phase machine. Two different methods are possible to convert the existing three-phase machine to a five-phase one with minimum cost. In the first method, a five-phase SynRM (SynRM 1) is obtained by replacing the existing stator by another one that has an integer number of slots per pole, i.e., a multiple of five. In the second method, a five-phase SynRM (SynRM 2) is obtained by rewinding the existing stator with a special type of winding. This is because the slot number of the existing stators is not a multiple of five. The novelty of the article is that two five-phase SynRMs are compared with the original three phase reference machine in terms of torque and torque ripple, in healthy and fault conditions. At rated condition and optimal current angle, SynRM 1 performs better than SynRM 2 in terms of rated torque: SynRM 1 and 2 have 11.8% and 6.6% higher torque than the three-phase machine. But, SynRM 1 has 25% more torque ripple than the three-phase reference machine, while SynRM 2 has 17% lower torque ripple. At faulty case, SynRM 1 and 2 work at 74% and 79% of the healthy rated torque of the three-phase SynRM, while the three-phase SynRM works at only 43% with a very huge torque ripple. Finally, experimental measurements are obtained to validate the theoretical work.

24 July 2020 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Kotb Basem TawfiqKotb Basem Tawfiq
Kotb Basem Tawfiq
Mohamed IbrahimMohamed Ibrahim
Mohamed Ibrahim
EEE. E. El-Kholy
E. E. El-Kholy
PSPeter Sergeant
Peter Sergeant

5 January 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
Kotb Basem TawfiqKotb Basem Tawfiq
Kotb Basem Tawfiq
Mohamed IbrahimMohamed Ibrahim
Mohamed Ibrahim
Hegazy RezkHegazy Rezk
Hegazy Rezk
EEElwy E. El-Kholy
Elwy E. El-Kholy
PSPeter Sergeant
Peter Sergeant
The interest in motor drive systems with a number of phases greater than three has increased, mainly in high-power industrial fields due to their advantages compared with three-phase drive systems. In this paper, comprehensive mathematical modeling of a five-phase matrix converter (MC) is introduced. Besides that, the direct and indirect space vector modulation (SVM) control methods are compared and analyzed. Furthermore, a mathematical model for the MC with the transformation between the indirect and direct topology is constructed. The indirect technique is used to control the five-phase MC with minimum switching losses. In this technique, SVM deals with a five-phase MC as a virtual two-stage converter with a virtual DC link (i.e., rectifier and inverter stages). The voltage gain is limited to a value of 0.79. Moreover, to analyze the effectiveness of the control technique and the advantages of the MC, a static R-L load is employed. However, the load can also be an industrial load, such as hospital pumping or vehicular applications. The presented analysis proves that the MC gives a wide range of output frequencies, and it has the ability to control the input displacement factor and the output voltage magnitude. In addition, the absence of the massive DC link capacitors is an essential feature for the MC, resulting in increased reliability and a reduced size converter. Eventually, an experimental validation is conducted on a static load to validate the presented model and the control method. It is observed that good matching between the simulation and the experimental results is achieved.