In situ remediation of contaminated groundwater often relies on the installation of a treatment zone (TZ) degrading the contamination. Zero‐valent‐iron (ZVI) is a type of reagent used for this purpose. Adequate delivery of ZVI in the whole target volume is particularly challenging and requires monitoring with high spatial resolution. We present a monitoring tool for imaging the dynamic spreading of ZVI and its associated ionic cloud, using cross‐borehole time‐lapse electrical resistivity tomography (ERT). This tool works in urban areas and is particularly suitable for achieving the required spatial resolution at the scale of the target volume. Groundwater and sediment samples show a consistent spatial and temporal distribution of the remediation cloud with cross‐borehole ERT. Yet, the 2D anomalies observed with cross‐borehole ERT provide a more spatially complete and rapid image of the remediation cloud distribution than if based solely on monitoring screens. At the study site, ZVI injection leads to uneven spreading, clearly documented by cross‐borehole ERT monitoring. The benefit of hydraulic conductivity (K) mapping by cross‐borehole induced polarization (IP) to understand unexpected injection paths (upstream leakage, spreading in preferred pathways) is investigated. A 2D, IP‐based, continuous, and coherent K‐distribution is obtained that compares well with estimations by grain size analyses from the TZ. However, the IP‐based K‐field fails at predicting injection paths, suggesting the creation of pathways during the high‐pressure injection of ZVI. Cross‐borehole time‐lapse ERT is the most promising geophysical tool for performance assessment of in situ remediation involving reagents with conductivity contrast.
Interaction of H2S escaping from magma and basaltic rocks leads to pyrite mineralization, witnessing active hydrothermal circulation. We study the possibility to track this process using geoelectrical methods. Complex conductivity spectra of 30 core samples from the Krafla volcano, Iceland, measured in the laboratory, indicate that pyrite can be discriminated from other minerals present in volcanic environments, such as iron oxides and clays. Joint evaluation of the maximum phase angle of electrical impedance and its real part at low frequency is required. The volume of metallic particles (pyrite or iron oxides) can be estimated from the maximum phase angle, but a decrease of the maximum phase angle with increased fluid conductivity or smectite volume is also observed and needs to be considered in the estimation. The laboratory observations can guide interpretation of field observations for estimation of pyrite volume in volcanic environments.
A new methodology was developed to support contaminant mass discharge (CMD)‐based risk assessment of groundwater contamination downgradient of point source zones. Geoelectrical cross‐borehole induced polarization (IP) data were collected at a site undergoing in situ remediation of chlorinated solvents for determining 2D hydraulic conductivity (K) distributions with an inversion model resolution of 0.15 m (vertically) x 0.50 m (horizontally) in three control planes from 10 to 20 m depth. Additionally, 18 slug tests and 31 grain size distribution analyses (GSA) from the control planes, were used for K‐estimation. The geometric means and variance of the IP, slug test, and GSA derived K‐estimates were consistent with previously studied sandy aquifers. Furthermore, the vertical variation in K between two geological settings, a sandy till and a meltwater sand formation, was clearly identified by the IP K‐estimates. The vertical variation was backed up by hydraulic profiling tool (HPT) measurements. Random realizations of CMD were simulated based on the cross‐borehole IP derived K‐values. For comparison, the CMD was also estimated with a geostatistical conditional simulation approach, using the data from slug tests and GSAs. The high IP resolution captured the small scale variations in K across the transects and led to CMD predictions with a narrow uncertainty interval, whereas slug test and GSA either under‐ or overestimated the magnitude of the areas with the highest CMD. Applying the geophysical cross‐borehole method for estimating K‐distributions in addition to traditional methods would improve CMD‐based risk assessment and evaluation of remediation performance at contaminated sites.
21 November 2022 in IEEE Transactions on Geoscience and Remote Sensing
The most common noise in geophysical data is probably the interference from powerlines. This noise manifests itself as a sinusoidal signal oscillating at the fundamental 50 Hz or 60 Hz frequency of the power grid and as harmonic components oscillating at integer multiples. Many different mitigation strategies, tailored for the specific geophysical method, have been developed to target powerline noise. One method that applies to fully sampled data is model-based subtraction, where a model of the powerline noise is fitted to the noisy data set and subsequently subtracted. In most cases, this leads to significant improvements in the signal-to-noise ratio. However, the determination of the powerline model parameters, in particular the fundamental powerline frequency, is computationally expensive, as it requires repeated solutions of a least-squares problem. We demonstrate that the powerline frequency can be directly predicted with a scientific machine-learning based approach. We work on both time domain induced polarization and surface nuclear magnetic resonance data. We use a different network for each method to trade-off prediction accuracy and prediction speed. In both cases, the prediction accuracy is fully on par with standard methods, and we obtain speed-ups by factors of 400 and 10 for the two types of data.