Aguinaldo Silveira e Silva

Aguinaldo Silveira e Silva

Auto-generated profile, based on publicly available information

Aguinaldo Silveira e Silva

Department of Electrical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2023 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
DCDalton Fellipe Casamali
Dalton Fellipe Casamali
AAAntonio Felipe da Cunha de Aquino
Antonio Felipe da Cunha de Aquino
ASAguinaldo Silveira e Silva
Aguinaldo Silveira e Silva

18 July 2020 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
KSKauana Palma Silva
Kauana Palma Silva
DCDalton Fellipe Casamali
Dalton Fellipe Casamali
ASAguinaldo Silveira e Silva
Aguinaldo Silveira e Silva

8 November 2025 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
VAVitor Antunes
Vitor Antunes
AAAntonio F. C. Aquino
Antonio F. C. Aquino
ASAguinaldo S. e Silva
Aguinaldo S. e Silva

16 February 2026 in IEEE Access
Verified
Journal Article
Open access
VAVitor Antunes
Vitor Antunes
AAAntonio C. Da Aquino
Antonio C. Da Aquino
ASAguinaldo S. E. Silva
Aguinaldo S. E. Silva
Power system stability is a fundamental requirement for ensuring reliable and secure operation of interconnected grids. Disturbances such as short circuits or generator trips can initiate or amplify electromechanical oscillations, which, if not properly damped, can compromise system integrity. In this paper, a data-driven approach known as Model-Free Adaptive Control (MFAC) is applied to the design of Power Oscillation Damping (POD) controllers for mitigating inter-area oscillation modes in large-scale power systems. Unlike traditional model-based techniques, the MFAC method does not require a mathematical model of the system, relying solely on real-time input–output data to adaptively adjust the control signal. This makes the controller particularly suitable for systems with significant nonlinearities and uncertain operating conditions. The proposed POD controllers are implemented as supplementary controllers on embedded High Voltage Direct Current (HVDC) links. Their performance is validated through two case studies: a test system composed of two HVDC links and eight synchronous generators, and a full-scale model of the Brazilian Interconnected Power System (BIPS). In both cases, the MFAC approach is applied to design POD controllers in multiple HVDC links, and the performance is compared with that of POD designs based on traditional techniques. In all evaluated scenarios, the MFAC controllers exhibit effective and efficient damping of inter-area oscillation modes. Additionally, the controllers demonstrate robust performance under large variations in power system operation.

9 February 2026 in IEEE Access
Verified
Journal Article
Open access
VAVitor Antunes
Vitor Antunes
ASAguinaldo Silveira E Silva
Aguinaldo Silveira E Silva
DIDiego Issicaba
Diego Issicaba
AAAntonio Felipe Da Cunha De Aquino
Antonio Felipe Da Cunha De Aquino
GMGuido Rossetto Moraes
Guido Rossetto Moraes
FMFabricio Andrade Mourinho
Fabricio Andrade Mourinho
In this paper, a methodology for validating and calibrating dynamic models in large interconnected power systems using synchronized measurements, is presented. The approach combines topological cuts at several hierarchical levels with Hybrid Dynamic Simulation (HDS), allowing the systematic validation of network partitions or indication of partitions with model inaccuracies. Discrepancy indicators computed from Phasor Measurement Units (PMU) data are employed for both, validation and detection of modeling inaccuracies. Once discrepancies are located, a calibration procedure is applied, which is formulated as an optimization problem and solved using Genetic Algorithms. The methodology is assessed on a test system using synthetic measurements and on the Brazilian Interconnected Power System (BIPS) using real disturbance records. The results indicate the effectiveness of the proposed methodology for model validation, the identification of inaccuracy sources, and model calibration.

13 August 2018 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
JMJoão C. Y. Menezes
João C. Y. Menezes
ASAguinaldo S. e Silva
Aguinaldo S. e Silva