Fabricio Andrade Mourinho

Fabricio Andrade Mourinho

Auto-generated profile, based on publicly available information

Fabricio Andrade Mourinho

Brazilian National Electric System Operator (BSO), Recife, Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2022 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
FMFabricio Andrade Mourinho
Fabricio Andrade Mourinho
TATatiana Assis
Tatiana Assis
This work presents a new methodology to assess the need of a retrofit plan to readjust anti-islanding protection of distributed energy resources (DERs) with focus on bulk power systems stability. The proposed approach aims to reduce DERs cascade disconnection during major disturbances in transmission networks, a phenomenon that can amplify or result in major blackouts in power systems with high or moderate DERs penetration. The proposed methodology is based on the assessment of Dynamic Security Regions with the incorporation of a simplified modeling to represent DERs cascade disconnection. As a result, recommendations for executing a retrofit plan with a low cost, preserving an adequate level of security, are provided. Initially, the impact of DERs disconnection on the Brazilian Interconnected Power Systems (BIPS) is demonstrated, highlighting the importance of modeling such effect in stability studies. Then, the proposed methodology is applied to the BIPS, evidencing its benefits by specifying the minimum amount of DERs that needs to be submitted to a retrofit plan to guarantee an adequate level of security.

9 February 2026 in IEEE Access
Verified
Journal Article
Open access
VAVitor Antunes
Vitor Antunes
ASAguinaldo Silveira E Silva
Aguinaldo Silveira E Silva
DIDiego Issicaba
Diego Issicaba
AAAntonio Felipe Da Cunha De Aquino
Antonio Felipe Da Cunha De Aquino
GMGuido Rossetto Moraes
Guido Rossetto Moraes
FMFabricio Andrade Mourinho
Fabricio Andrade Mourinho
In this paper, a methodology for validating and calibrating dynamic models in large interconnected power systems using synchronized measurements, is presented. The approach combines topological cuts at several hierarchical levels with Hybrid Dynamic Simulation (HDS), allowing the systematic validation of network partitions or indication of partitions with model inaccuracies. Discrepancy indicators computed from Phasor Measurement Units (PMU) data are employed for both, validation and detection of modeling inaccuracies. Once discrepancies are located, a calibration procedure is applied, which is formulated as an optimization problem and solved using Genetic Algorithms. The methodology is assessed on a test system using synthetic measurements and on the Brazilian Interconnected Power System (BIPS) using real disturbance records. The results indicate the effectiveness of the proposed methodology for model validation, the identification of inaccuracy sources, and model calibration.

30 October 2025 in IEEE Access
Verified
Journal Article
Open access
RRRodrigo Andrade Ramos
Rodrigo Andrade Ramos
MNMatheus Rosa Nascimento
Matheus Rosa Nascimento
GMGiovanna Siqueira Mayese
Giovanna Siqueira Mayese
ANAgilio Coutinho Netto
Agilio Coutinho Netto
Antonio Carlos Zambroni de SouzaAntonio Carlos Zambroni de Souza
Antonio Carlos Zambroni de Souza
IDIldemar Cassana Decker
Ildemar Cassana Decker
The increasing uncertainty in power systems, driven by demand variability and renewable production, has increased operational complexity and brought systems closer to their stability limits. Phasor Measurement Units (PMUs) play a vital role in addressing these challenges. Transmission System Operators (TSOs) rely on PMUs during planning stages to validate models for critical decisions, such as setting power exchange limits. However, discrepancies between PMU data and simulations have been observed, and the insufficient integration of PMUs in sub-transmission and distribution networks further complicates the identification of their root causes. This limited integration hinders data accessibility for TSOs, resulting in significant information gaps, especially in systems with Distributed Energy Resources (DERs). Within this context, the main contribution of this paper is the development of an approach based on power flow data to rank the priority of buses outside the main grid for PMU allocation, with the goal of enhancing load models and increasing the TSO’s monitoring coverage. For each operating point, buses are ranked by measurement allocation indices, considering load, DERs, and the electrical influence of predefined disturbances. These rankings, combined with a diversified allocation strategy, suggest candidate buses for meter installation. A proof of concept explains the method, followed by its application to the Southeastern subsystem of the Brazilian Interconnected Power System (BIPS). Results show that regionalizing the ranking is essential for identifying prioritized points in all areas and voltage levels. Similarly, a geographic diversity in the distribution of meters is observed in the results, promoting a more representative allocation to capture particular features of each region of the BIPS.