Line-commutated converter based high-voltage direct-current (LCC-HVDC) has been extensively applied in power system. LCC-HVDC is prone to continuous commutation failure (CCF), which consequently causes numerous active and reactive impacts, thereby resulting in various power system security and stability issues. Given that there is no CCF predictive method at present, the effect of CCF suppression measure is still limited, and the control margin of DC commutation station and power grid cannot be fully applied, so that the negative impact of CCF is difficult to reduce through advance control. In view of this situation, this paper aims at proposing a predictive method of LCC-HVDC CCF, which occurs again during the first CF recovery process. First, the predictability of CCF is demonstrated, and the idea for predicting CCF by comparing commutation voltage is proposed; Second, the calculation equation of CCF threshold voltage is derived by analyzing the CF process; Third, a predictive method of CCF based on threshold commutation voltage is proposed; Finally, the correctness of the theoretical analysis and predictive method is verified through the CIGRE HVDC standard system. Simulation shows that the proposed method has high accuracy and can provide sufficient time margin for emergency control to suppress the LCC-HVDC CCF.
As loads connected to active distribution network (ADN) grow, ADN’s voltage safety issues are becoming more serious. At present, the solution is mainly to build more distributed generation (DG) or to adjust the reactive power in the whole network, but the former needs a lot of investment while the latter requires a large amount of communication equipment and it takes a long time to calculate the adjustment amount of reactive power and to coordinate reactive power compensation equipment. When the loads are heavy, there will still be drawbacks of insufficient reactive power. Therefore, this paper analyzes the relationship between the active power, reactive power, and the voltage in the ADN. Through the autonomous region (AR) division, a voltage control method based on the active power variation and adjustable power in the AR is proposed. According to the relationship between the amount of active power and the adjustable amount active power, the active power control, the reactive power control, and the coordinated control of active power reactive power control are adopted to adjust the DGs’ output to stabilize the bus voltage. The simulation results show that the proposed method can effectively improve the voltage control capability of ADN and can enable it to operate normally under greater power changes. Through the control method in this paper, the communication requirements are greatly reduced and the calculation time is effectively shortened and is more adaptable.
The charging station (CS) is generally directly off-grid under a grid fault, which has become a key technical bottleneck that restricts the sustainable development of new energy transportation systems. During a grid fault, the CS under the vehicle-to-grid (V2G) mode experiences a reduction in active power due to the current limitation of the voltage source converter (VSC), which may cause the DC voltage to exceed its limitations under unbalanced power. The effect of the active and reactive power of CS in low- and medium-voltage distribution networks on supporting the PCC voltage under the limitation of DC voltage and VSC current has not been analyzed, and a control method for PCC voltage support for CS has not been established. Therefore, a power boundary that avoids the DC overvoltage and AC overcurrent of the CS is defined. A power feasible region for the CS considering fault duration is established. The characteristic that the power feasible region shrinks with the increase in duration is found, and a calculation method for the critical clearing time of a fault to avoid DC overvoltage is proposed. The relationship between PCC voltage and power injected by the CS is analyzed. The property that the control point of maximum voltage support lies at the boundary of the power feasible region is revealed. A control method of PCC voltage support that considers the limitation of DC voltage and VSC current for the CS is proposed. Simulation verification shows that the support capability of CS for PCC voltage during a fault is significantly enhanced by the proposed method while securing the DC voltage.
The cyber–physical deep integration in distribution networks containing distributed generators (DGs) enables false data injection attacks (FDIAs) through data tampering in monitoring systems, posing cross-domain threats to power system security. Effective FDIA identification methods remain unavailable for distribution networks containing DGs under distributed cluster control. The cyber–physical interaction characteristics are systematically analyzed in the cyber–physical system (CPS) of distribution networks containing DGs under distributed cluster control. A latent FDIA model is established with a specific attack penetration pattern being revealed. The operational impact mechanism of latent FDIAs on distributed cluster control is theoretically elucidated. A synchronous detection signal-based localization methodology is developed for latent FDIAs, coupled with an attack signal computation algorithm. These innovations enable dynamic attack identification and proactive signal isolation, thereby facilitating subsequent defense operations by system operators. Simulation results confirm the effectiveness of the proposed dynamic identification method for latent FDIAs in distribution networks containing DGs.