Han Yao

Han Yao

Auto-generated profile, based on publicly available information

Han Yao

School of Physics, Nanjing University of Science and Technology, Nanjing, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2021 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
CDCameron Deans
Cameron Deans
YCYuval Cohen
Yuval Cohen
HYHan Yao
Han Yao
BMBenjamin Maddox
Benjamin Maddox
AVAntonio Vigilante
Antonio Vigilante
FRFerruccio Renzoni
Ferruccio Renzoni
We demonstrate electromagnetic induction imaging with an unshielded, portable radio frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head, the active compensation of the ambient magnetic field, and the implementation of a dedicated procedure to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.

31 October 2022 in Optics Express
Verified
Journal Article
Open access
HYHan Yao
Han Yao
BMBenjamin Maddox
Benjamin Maddox
FRFerruccio Renzoni
Ferruccio Renzoni
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.

18 March 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DMDanyue Ma
Danyue Ma
MDMing Ding
Ming Ding
Jixi LuJixi Lu
Jixi Lu
HYHan Yao
Han Yao
JZJunpeng Zhao
Junpeng Zhao
BHBangcheng Han
Bangcheng Han
A stable magnetic field environment is one of the key factors to realize the ultrasensitive magnetic field detection. Ferrite materials, which possess both high electrical resistivity and high permeability, are ideal magnetic shielding materials. Gaps and holes usually exist in the large size magnetic shield which effect shielding effectiveness. In this paper, the variation of the DC magnetic shielding ratio, for different gaps and access hole dimensions, is quantificationally investigated using the finite element method. The shielding ratio in the simulation is close to the theoretical calculation for the closed shield when the thickness of gaps is very small. Our study indicates that gaps and holes separately reduced the shielding effectiveness, and the coexistence of gaps and holes aggravated the reduction of shielding effectiveness. Compared with shielding ratio of the ferrite enclosure without gaps and holes for the known size shield, the transverse and longitudinal direction of the shielding ratio increase by 9% and 274% with gaps (thickness=0.1 mm) and holes (diameter=25 mm), respectively. The simulation results are partially verified with experimentally using cylindrical ferrite shield made of Zn0.17Mn0.74Fe2.06O4 and Zn0.33Mn0.58Fe2.06O4. The difference between the experimental and simulation results is less than 10%.

19 October 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
HYHan Yao
Han Yao
YLYang Li
Yang Li
DMDanyue Ma
Danyue Ma
JCJiashu Cai
Jiashu Cai
JZJunpeng Zhao
Junpeng Zhao
MDMing Ding
Ming Ding
An acousto-optic modulation (AOM) detection method is demonstrated to detect the atomic Larmor precession frequency in an all-optical K-Rb atomic magnetometer operated in Spin-Exchange Relaxation Free (SERF) regime. Magnetic field sensitivity of 14 fT/Hz1/2 was achieved by employing the uniform design (UD) [Acta Math Appl Sin. 3, 363 (1980)] and subsequently optimizing the AOM modulation conditions. Results were compared to those of Faraday and the balanced polarimetry method in the same magnetometer. The AOM detection method has several advantages, such as small volume, no extra magnetic shielding for the modulator, high measurement signal-to-noise ratio and stability. It has a good prospect for compact and multi-channel atomic magnetometers.

27 March 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BMBenjamin Maddox
Benjamin Maddox
CDCameron Deans
Cameron Deans
HYHan Yao
Han Yao
YCYuval Cohen
Yuval Cohen
FRFerruccio Renzoni
Ferruccio Renzoni
We present an apparatus to overcome the limitations of mechanical raster-scanning in electromagnetic induction imaging (EMI) techniques by instead performing a 2D optical raster-scan within the vapour cell of a radio-frequency atomic magnetometer (RF-AM). A large cuboidal 87 Rb vapour cell is employed to act as the medium of an RF-AM with the pump and probe beams translated in the cell via acousto-optics. The technique is shown to give robust and repeatable magnetic measurements over the cell volume and successfully resolves conductive targets with EMI. Optical raster-scanning removes the limitation of slow mechanical actuation and a fast imaging procedure is enacted resolving conductive targets at a rate of 40 ms/pixel.

1 August 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
HYHan Yao
Han Yao
HZHong Zhang
Hong Zhang
DMDanyue Ma
Danyue Ma
JZJunpeng Zhao
Junpeng Zhao
MDMing Ding
Ming Ding
The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.