Tomohiro Yamada

Tomohiro Yamada

Auto-generated profile, based on publicly available information

Tomohiro Yamada

Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2024 in ACS Omega
Verified
Journal Article
Open access
TYTomohiro Yamada
Tomohiro Yamada
YTYuki Tobimatsu
Yuki Tobimatsu
TNThi Thi Nge
Thi Thi Nge
YMYusuke Matsumoto
Yusuke Matsumoto
TYTatsuhiko Yamada
Tatsuhiko Yamada
Glycol lignin (GL) is produced via the acid-catalyzed solvolysis of softwood meal using glycols such as polyethylene glycol. The physicochemical and thermal properties of GL are expected to be controllable by varying the glycol type. In this study, caprylyl glycol (CG), which is a biobased glycol derived from the caprylic acid component of coconut and palm oils, was used to investigate the effects on the acid-catalyzed solvolysis of softwood. The reactions were performed at 140, 150, and 160 °C for 30–120 min to obtain lignin derivatives (CG-lignin: CGL). The chemical and physical properties of CGLs were investigated. Two-dimensional heteronuclear single-quantum coherence nuclear magnetic resonance analysis suggested that CGL possesses an α-CG-β-O-4 structure as CG is grafted onto the lignin structure. CGLs prepared at higher reaction temperatures exhibited lower molecular weights. The thermomechanical analysis of CGL revealed a glass transition temperature of 89–96 °C and a viscous thermal flow temperature of 134–155 °C.

12 December 2021
Verified
Conference Paper
Closed access
TYT. Yamada
T. Yamada
KTK. Takagi
K. Takagi
MFM. Fujieda
M. Fujieda
YTYoshimitsu Takahashi
Yoshimitsu Takahashi
YHYasuhiko Hayashi
Yasuhiko Hayashi
In inverter-fed motors, enough insulation film thickness is required to prevent partial discharge in the air gap between coils caused by high voltage. In this paper, for better insulation design of a motor, the behavior of surge voltage in the motor and position of partial discharge caused by surge voltage is discussed. The partial discharge occurrence position is evaluated by detection of the electromagnetic wave using multiple antennas when the voltage is applied to single phase coils of the motor. The comparison of voltage distribution and partial discharge point indicates the surge voltage waveform between coils due to resonance differs intricately for each coil. Moreover, partial discharge occurs in the part where the voltage value between coils is large.