4 June 2021 in IEEE Sensors Journal
Natural gas pipeline network extends over 2.5 million miles in the united states of America. The aging of these infrastructures combined with damage from various external threats are creating safety concerns for both operators and residents in the vicinity of these pipelines. In this paper, we are presenting a miniaturized structured light based three-dimensional (3D) imaging sensor for the inspection of internal walls of plastic natural gas distribution pipelines. The sensor is an 18-mm diameter optical inspection device that can be inserted inside the pipe to provide the operator with a 3D map of the internal surface of the inspected pipe. The introduction of the 3D map simplifies the identification of damages like deformations and material loss and leads to a better evaluation of the damage severity when compared to LED assisted cameras. The sensor is also accompanied with an embedded electronic stabilization algorithm to reduce the effect of misalignment when the sensor is attached to a scanning platform, and to facilitate the registration of consecutive frames from the sensor. The algorithm exploits the geometry constraints provided by the cylindrical shape of the pipe to estimate the orientation and position of the sensor with each collected frame.
18 August 2023 in NDT & E International
4 November 2021 in Journal of Applied Physics
Microwave-induced thermoacoustic imaging (TAI) is a hybrid imaging technique that combines electromagnetic radiation and ultrasonic waves to achieve high imaging contrast and submillimeter spatial resolution. These characteristics make TAI a good candidate to detect material anomalies that change the material electric properties without a noticeable variation in material density. Conventional pulsed TAI systems work by sending a single short pulse to the imaged target and then detecting the generated pressure signal; therefore, a very high peak power microwave pulse or data averaging is needed to produce images with a high signal-to-noise ratio (SNR). In this paper, we propose to enhance the SNR of pulsed TAI systems by using non-coherent pulse compression. In this approach, a predefined pulse coded signal is used to illuminate the imaged sample and the received pressure signal is cross correlated with a template that is related to the power profile of the excitation signal. The proposed approach can be easily deployed to pulsed TAI systems without the need for major system modifications to the RF source because it only requires a timing circuit to control the triggering time of the RF pulses. In this paper, we demonstrate experimentally that the proposed approach highly improves the SNR of TAI signals and images and can be used to reduce the acquisition time by lowering the number of data averaging or reduce the required peak power from RF sources.