Mohand Alzuhiri

Mohand Alzuhiri

Auto-generated profile, based on publicly available information

Mohand Alzuhiri

Department of Electrical and Computer Engineering, Michigan State University , East Lansing, MI 48823, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMohand Alzuhiri
Mohand Alzuhiri
KFKhalid Farrag
Khalid Farrag
ELErnest Lever
Ernest Lever
YDYiming Deng
Yiming Deng
Natural gas pipeline network extends over 2.5 million miles in the united states of America. The aging of these infrastructures combined with damage from various external threats are creating safety concerns for both operators and residents in the vicinity of these pipelines. In this paper, we are presenting a miniaturized structured light based three-dimensional (3D) imaging sensor for the inspection of internal walls of plastic natural gas distribution pipelines. The sensor is an 18-mm diameter optical inspection device that can be inserted inside the pipe to provide the operator with a 3D map of the internal surface of the inspected pipe. The introduction of the 3D map simplifies the identification of damages like deformations and material loss and leads to a better evaluation of the damage severity when compared to LED assisted cameras. The sensor is also accompanied with an embedded electronic stabilization algorithm to reduce the effect of misalignment when the sensor is attached to a scanning platform, and to facilitate the registration of consecutive frames from the sensor. The algorithm exploits the geometry constraints provided by the cylindrical shape of the pipe to estimate the orientation and position of the sensor with each collected frame.

18 August 2023 in NDT & E International
Verified
Journal Article
Closed access
MAMohand Alzuhiri
Mohand Alzuhiri
ZLZi Li
Zi Li
ARAdithya Rao
Adithya Rao
JLJiaoyang Li
Jiaoyang Li
PFPreston Fairchild
Preston Fairchild
YDYiming Deng
Yiming Deng

4 November 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
MAMohand Alzuhiri
Mohand Alzuhiri
JSJian Song
Jian Song
BLBo Li
Bo Li
DKDeepak Kumar
Deepak Kumar
Zhen QiuZhen Qiu
Zhen Qiu
YDYiming Deng
Yiming Deng
Microwave-induced thermoacoustic imaging (TAI) is a hybrid imaging technique that combines electromagnetic radiation and ultrasonic waves to achieve high imaging contrast and submillimeter spatial resolution. These characteristics make TAI a good candidate to detect material anomalies that change the material electric properties without a noticeable variation in material density. Conventional pulsed TAI systems work by sending a single short pulse to the imaged target and then detecting the generated pressure signal; therefore, a very high peak power microwave pulse or data averaging is needed to produce images with a high signal-to-noise ratio (SNR). In this paper, we propose to enhance the SNR of pulsed TAI systems by using non-coherent pulse compression. In this approach, a predefined pulse coded signal is used to illuminate the imaged sample and the received pressure signal is cross correlated with a template that is related to the power profile of the excitation signal. The proposed approach can be easily deployed to pulsed TAI systems without the need for major system modifications to the RF source because it only requires a timing circuit to control the triggering time of the RF pulses. In this paper, we demonstrate experimentally that the proposed approach highly improves the SNR of TAI signals and images and can be used to reduce the acquisition time by lowering the number of data averaging or reduce the required peak power from RF sources.