Simin Masihi

Simin Masihi

Auto-generated profile, based on publicly available information

Simin Masihi

Electrical and Computer Engineering Department, Western Michigan University, Kalamazoo, MI, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2021 in ACS Sensors
Verified
Journal Article
Open access
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
AHAnthony J. Hanson
Anthony J. Hanson
ABArnesh K. Bose
Arnesh K. Bose
Massood AtashbarMassood Atashbar
Massood Atashbar
A novel porous polydimethylsiloxane (PDMS)-based capacitive pressure sensor was fabricated by optimizing the dielectric layer porosity for wide-range pressure sensing applications in the sports field. The pressure sensor consists of a porous PDMS dielectric layer and two fabric-based conductive electrodes. The porous PDMS dielectric layer was fabricated by introducing nitric acid (HNO3) into a mixture of PDMS and sodium hydrogen bicarbonate (NaHCO3) to facilitate the liberation of carbon dioxide (CO2) gas, which induces the creation of porous microstructures within the PDMS dielectric layer. Nine different pressure sensors (PS1, PS2,..., PS9) were fabricated in which the porosity (pore size, thickness) and dielectric constant of the PDMS dielectric layers were varied by changing the curing temperature, the mixing proportions of the HNO3/PDMS concentration, and the PDMS mixing ratio. The response of the fabricated pressure sensors was investigated for the applied pressures ranging from 0 to 1000 kPa. A relative capacitance change of ∼100, ∼323, and ∼485% was obtained by increasing the curing temperature from 110 to 140 to 170 °C, respectively. Similarly, a relative capacitance change of ∼170, ∼282, and ∼323% was obtained by increasing the HNO3/PDMS concentration from 10 to 15 to 20%, respectively. In addition, a relative capacitance change of ∼94, ∼323, and ∼460% was obtained by increasing the PDMS elastomer base/curing agent ratio from 5:1 to 10:1 to 15:1, respectively. PS9 exhibited the highest sensitivity over a wide pressure sensing range (low-pressure ranges (<50 Pa), 0.3 kPa–1; high-pressure ranges (0.2–1 MPa), 3.2 MPa–1). From the results, it was observed that the pressure sensors with dielectric layers prepared at relatively higher curing temperatures, higher HNO3 concentrations, and higher PDMS ratios resulted in increased porosity and provided the highest sensitivity. As an application demonstrator, a wearable fit cap was developed using an array of 16 pressure sensors for measuring and mapping the applied pressures on a player’s head while wearing a helmet. The pressure mapping aids in observing and understanding the proper fit of the helmet in sports applications.

21 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VPValliammai Palaniappan
Valliammai Palaniappan
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
ABArnesh K. Bose
Arnesh K. Bose
MAMassood Z. Atashbar
Massood Z. Atashbar
A novel capacitive pressure sensor based on micro-structured polydimethylsiloxane (PDMS) dielectric layer was developed for wearable E-skin and touch sensing applications. The pressure sensor was fabricated on a flexible polyethylene terephthalate (PET) substrate, using PDMS and silver (Ag) as the dielectric and electrode layers, respectively. A set of PDMS films with pyramid shaped micro-structures were fabricated using a laser engraved acrylic mold. The electrodes (top and bottom) were fabricated by depositing Ag on PET films using additive screen-printing process. The pressure sensor was assembled by attaching the top and bottom Ag electrodes to the smooth side of pyramid shaped micro-structured PDMS (PM-PDMS) films. The top PM-PDMS was then placed on the bottom PM-PDMS. The capability of the fabricated pressure sensor was investigated by subjecting the sensor to pressures ranging from 0 to 10 kPa. A sensitivity of 0.221% Pa-1, 0.033% Pa-1 and 0.011% Pa-1 along with a correlation coefficient of 0.9536, 0.9586 and 0.9826 was obtained for the pressure sensor in the pressure range of 0 Pa to 100 Pa, 100 Pa to 1000 Pa, and 1 kPa to 10 kPa, respectively. The pressure sensor also possesses a fast response time of 50 ms, low hysteresis of 0.7%, recovery time of 150 ms and excellent cycling stability over 1000 cycles. The results demonstrated the efficient detection of pressure generated from various activities such as hand gesture and carotid pulse measurement. The PM-PDMS based pressure sensor offers a simple and cost-effective approach to monitor pressure in E-skin applications.

15 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Arnesh BoseArnesh Bose
Arnesh Bose
XZXingzhe Zhang
Xingzhe Zhang
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Massood AtashbarMassood Atashbar
Massood Atashbar
A printed strain gauge based on metal/non-metal composite was successfully fabricated and tested for micro-strain (μƐ) detection. A silver ink was blended with a carbon ink to achieve a silver-carbon (Ag/C) composite ink. The composite ink was then screen printed on a polyimide substrate in a meandering pattern to achieve a desired resistance of ~350 Ω. The printed strain gauge was bonded on to a flat aluminum beam. The capability of the printed strain gauge to detect linear strain was investigated by applying varying tensile and compressive loads on the aluminum beam, to simulate μƐ. Corresponding linear gauge factors for tensile and compressive loads were calculated as 2.26 and 1.47, respectively. In addition, transverse gauge factors for tensile and compressive loads were calculated as 1.18 and 0.43, respectively. The strain gauge has a temperature coefficient resistance of 0.26 %/°C. The screen-printed Ag/C composite strain gauge was also compared to a commercial strain gauge of similar gauge resistance. The results demonstrate that a strain gauge with screen-printed Ag/C and encapsulation ink on a polyimide substrate can be utilized for μƐ detection. The electromechanical response of the fabricated strain gauge as a function of resistance is investigated and presented in this paper.

29 September 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
AHAnthony J. Hanson
Anthony J. Hanson
SFStephen Fenech
Stephen Fenech
Massood AtashbarMassood Atashbar
Massood Atashbar
A flexible wireless electrocardiogram (ECG) device, integrated with fabric was fabricated for monitoring physiological signals in wearable biomedical applications. The ECG device consists of dry electrodes and a readout module. The dry electrode was fabricated by depositing multi-walled carbon nanotube (MWCNTs)/polydimethyl-siloxane (PDMS) composite on a thermoplastic polyurethane (TPU) substrate with screen printed silver (Ag) layer. The readout module with wireless data transmission capability was designed and fabricated on a flexible polyimide substrate. The ECG device was attached to fabric, and its performance was investigated by measuring the ECG signals and comparing them with the results of conventional wet Ag/AgCl electrode. It was observed that the device demonstrated similar performance in terms of signal intensity and correlation when compared to the conventional wet ECG electrodes. Signal-to-noise-ratio (SNR) analysis clearly showed that the dry electrodes with an average SNR of 23.1 dB, perform better than the commercially available Ag/AgCl electrodes (SNR of 21.2 dB). In addition, the capability of the fabric based dry electrodes to measure ECG signals during the physiological activities under exercise motions was studied. This enabled understanding the effect of motion artifacts on the dry electrode response and allowed comparing the obtained ECG signals with the responses of conventional wet ECG electrodes (subjected to similar conditions). It was observed that, even though dry electrodes didn’t use any kind of adhesive gel for measuring the ECG signals, they performed very similar to conventional wet electrodes. The results obtained clearly demonstrated the feasibility of employing fabric based flexible dry ECG electrodes for continuous monitoring of ECG signals in health care applications and can potentially replace the wet electrodes.

16 November 2020 in IEEE Access
Verified
Journal Article
Open access
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
XZXingzhe Zhang
Xingzhe Zhang
Arnesh BoseArnesh Bose
Arnesh Bose
SMSimin Masihi
Simin Masihi
BNBinu B. Narakathu
Binu B. Narakathu
Massood AtashbarMassood Atashbar
Massood Atashbar
A flexible capacitive force sensor was developed for force sensing applications. The force sensor consists of two electrodes and a dielectric layer. The electrodes were fabricated by depositing conductive silver (Ag) ink on a flexible polyimide platform using screen-printing process. The dielectric layer was prepared by mixing the contents of polydimethylsiloxane (PDMS) (pre-polymer and curing agent) in a 16:1 ratio. Then the PDMS dielectric layer was sandwiched between the screen-printed Ag electrodes. The capability of the fabricated force sensor was investigated by recording its capacitive response for varying applied forces of 100 N. It was observed that the capacitance increased from 5.83 pF to 6.36 pF as the force was increased from 0 N (no load) to 100 N. A sensitivity and correlation coefficient of 0.081%N −1 and 0.998 were calculated for the force sensor. In addition, a response time and recovery time of 3.7 seconds and 5.7 seconds was measured for the fabricated force sensor. The relative humidity (% RH) tests performed from 20% RH to 80% RH, in steps of 20% RH, revealed that there was a minimal effect of RH on the base capacitance of the force sensor at room temperature.

13 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
ABArnesh K. Bose
Arnesh K. Bose
XZXingzhe Zhang
Xingzhe Zhang
MAMassood Z. Atashbar
Massood Z. Atashbar
Design and rapid prototyping of a tunable and compact microstrip antenna for industrial, scientific and medical (ISM) band applications is presented in this paper. Laser machining is introduced as a fast and accurate method for the antenna fabrication. The antenna, with an overall dimension of 65 × 46 × 0.127 mm, was fabricated by sandwiching a flexible Kapton polyimide substrate, with a dielectric constant of 3.5, between two flexible copper tapes, as the radiating patch and ground plane, respectively. The radiating patch was patterned in a meander configuration,with three slots, demonstrating the capability to reduce the resonant frequency of the microstrip antenna from 2.4 GHz to 900 MHz, without increasing the overall size of the antenna (87% compact). The effect of mechanical stress on the antenna performance was investigated by performing bend and stretch tests. The antenna was subjected to compressive bend with a minimum radius of curvature of 86 mm and 150 mm along the x-axis and y-axis which resulted in a maximum increase of resonant frequency by 3.1% and 1.3%, respectively. Similarly, the antenna was subjected to tensile bend with a minimum radius of curvature of 79 mm and 162 mm along the x-axis and y-axis which resulted in a maximum decrease of the resonant frequency by 4.2% and 0.3%, respectively. An overall 0.9% decrease in the resonant frequency was measured for an applied strain of 0.09% during stretching the antenna along the y-axis.