Dinesh Maddipatla

Dr. Dinesh Maddipatla

Western Michigan University, Kalamazoo, Michigan, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2021 in ACS Sensors
Verified
Journal Article
Open access
SMSimin Masihi
Simin Masihi
MPMasoud Panahi
Masoud Panahi
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
AHAnthony J. Hanson
Anthony J. Hanson
ABArnesh K. Bose
Arnesh K. Bose
Massood AtashbarMassood Atashbar
Massood Atashbar
A novel porous polydimethylsiloxane (PDMS)-based capacitive pressure sensor was fabricated by optimizing the dielectric layer porosity for wide-range pressure sensing applications in the sports field. The pressure sensor consists of a porous PDMS dielectric layer and two fabric-based conductive electrodes. The porous PDMS dielectric layer was fabricated by introducing nitric acid (HNO3) into a mixture of PDMS and sodium hydrogen bicarbonate (NaHCO3) to facilitate the liberation of carbon dioxide (CO2) gas, which induces the creation of porous microstructures within the PDMS dielectric layer. Nine different pressure sensors (PS1, PS2,..., PS9) were fabricated in which the porosity (pore size, thickness) and dielectric constant of the PDMS dielectric layers were varied by changing the curing temperature, the mixing proportions of the HNO3/PDMS concentration, and the PDMS mixing ratio. The response of the fabricated pressure sensors was investigated for the applied pressures ranging from 0 to 1000 kPa. A relative capacitance change of ∼100, ∼323, and ∼485% was obtained by increasing the curing temperature from 110 to 140 to 170 °C, respectively. Similarly, a relative capacitance change of ∼170, ∼282, and ∼323% was obtained by increasing the HNO3/PDMS concentration from 10 to 15 to 20%, respectively. In addition, a relative capacitance change of ∼94, ∼323, and ∼460% was obtained by increasing the PDMS elastomer base/curing agent ratio from 5:1 to 10:1 to 15:1, respectively. PS9 exhibited the highest sensitivity over a wide pressure sensing range (low-pressure ranges (<50 Pa), 0.3 kPa–1; high-pressure ranges (0.2–1 MPa), 3.2 MPa–1). From the results, it was observed that the pressure sensors with dielectric layers prepared at relatively higher curing temperatures, higher HNO3 concentrations, and higher PDMS ratios resulted in increased porosity and provided the highest sensitivity. As an application demonstrator, a wearable fit cap was developed using an array of 16 pressure sensors for measuring and mapping the applied pressures on a player’s head while wearing a helmet. The pressure mapping aids in observing and understanding the proper fit of the helmet in sports applications.

3 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
BNBinu B. Narakathu
Binu B. Narakathu
Massood AtashbarMassood Atashbar
Massood Atashbar
This review provides an outlook on some of the significant research work done on printed and flexible sensors. Printed sensors fabricated on flexible platforms such as paper, plastic and textiles have been implemented for wearable applications in the biomedical, defense, food, and environmental industries. This review discusses the materials, characterization methods, and fabrication methods implemented for the development of the printed and flexible sensors. The applications, challenges faced and future opportunities for the printed and flexible sensors are also presented in this review.

18 May 2020 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
MOManuel Ochoa
Manuel Ochoa
RRRahim Rahimi
Rahim Rahimi
JZJiawei Zhou
Jiawei Zhou
Hongjie JiangHongjie Jiang
Hongjie Jiang
CYChang Keun Yoon
Chang Keun Yoon
Babak ZiaieBabak Ziaie
Babak Ziaie
Chronic wounds affect over 6.5 million Americans and are notoriously difficult to treat. Suboptimal oxygenation of the wound bed is one of the most critical and treatable wound management factors, but existing oxygenation systems do not enable concurrent measurement and delivery of oxygen in a convenient wearable platform. Thus, we developed a low-cost alternative for continuous O2 delivery and sensing comprising of an inexpensive, paper-based, biocompatible, flexible platform for locally generating and measuring oxygen in a wound region. The platform takes advantage of recent developments in the fabrication of flexible microsystems including the incorporation of paper as a substrate and the use of a scalable manufacturing technology, inkjet printing. Here, we demonstrate the functionality of the oxygenation patch, capable of increasing oxygen concentration in a gel substrate by 13% (5 ppm) in 1 h. The platform is able to sense oxygen in a range of 5–26 ppm. In vivo studies demonstrate the biocompatibility of the patch and its ability to double or triple the oxygen level in the wound bed to clinically relevant levels.

16 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XZXingzhe Zhang
Xingzhe Zhang
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
Arnesh BoseArnesh Bose
Arnesh Bose
SHSajjad Hajian
Sajjad Hajian
BNBinu B. Narakathu
Binu B. Narakathu
Massood AtashbarMassood Atashbar
Massood Atashbar
A resistive flexible humidity sensor based on multi-walled carbon nanotubes (MWCNTs) was designed and fabricated. Screen and gravure printing processes were used for monolithically fabricating the humidity sensor containing interdigitated electrodes (IDE), a sensing layer and a meandering conductive heater. An average thickness and surface roughness of 0.99 μm and 0.23 μm, respectively, was registered for the printed MWCNTs sensing layer. The capability of the printed sensor, with heater, was investigated by subjecting it to relative humidity (RH) ranging from 10% to 90%. The response demonstrated an overall resistance change of 55% when the sensor was subjected to 90% RH, when compared to 10% RH. A maximum hysteresis of 5.1%, at 70% RH, was calculated for the resistive response of the sensor. The printed sensors can be bend with radius of curvature of 1.5 inch with literally no effect.

1 August 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
VTVikram S. Turkani
Vikram S. Turkani
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
BNBinu B. Narakathu
Binu B. Narakathu
BBBradley J. Bazuin
Bradley J. Bazuin
MAMassood Z. Atashbar
Massood Z. Atashbar

1 May 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MAMohammed Mohammed Ali
Mohammed Mohammed Ali
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
BNBinu B. Narakathu
Binu B. Narakathu
ACAmer Abdulmahdi Chlaihawi
Amer Abdulmahdi Chlaihawi
SESepehr Emamian
Sepehr Emamian
Massood AtashbarMassood Atashbar
Massood Atashbar