Tiffany Beaumont

Tiffany Beaumont

Auto-generated profile, based on publicly available information

Tiffany Beaumont

Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSE-SANTE/SDOS/LEDI, Fontenay-aux-Roses, France

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
TBTiffany Beaumont
Tiffany Beaumont
PIPedro Caldeira Ideias
Pedro Caldeira Ideias
MRMaeva Rimlinger
Maeva Rimlinger
DBDavid Broggio
David Broggio
DFDidier Franck
Didier Franck
In the case of a nuclear reactor accident the release contains a high proportion of iodine-131 that can be inhaled or ingested by members of the public. Iodine-131 is naturally retained in the thyroid and increases the thyroid cancer risk. Since the radiation induced thyroid cancer risk is greater for children than for adults, the thyroid dose to children should be assessed as accurately as possible. For that purpose direct measurements should be carried out with age-specific calibration factors but, currently, there is no age-specific thyroid phantoms allowing a robust measurement protocol. A set of age-specific thyroid phantoms for 5, 10, 15 year old children and for the adult has been designed and 3D printed. A realistic thyroid shape has been selected and material properties taken into account to simulate the attenuation of biological tissues. The thyroid volumes follow ICRP recommendations and the phantoms also include the trachea and a spine model. Several versions, with or without spine, with our without trachea, with or without age-specific neck have been manufactured, in order to study the influence of these elements on calibration factors. The calibration factor obtained with the adult phantom and a reference phantom are in reasonable agreement. In vivo calibration experiments with germanium detectors have shown that the difference in counting efficiency, the inverse of the calibration factor, between the 5 year and adult phantoms is 25% for measurement at contact. It is also experimentally evidenced that the inverse of the calibration factor varies linearly with the thyroid volume. The influence of scattering elements like the neck or spine is not evidenced by experimental measurements.

1 October 2019 in Radiation Measurements
Verified
Journal Article
Closed access
ALA.L. Lebacq
A.L. Lebacq
MSM.A. Saizu
M.A. Saizu
MTM. Takahashi
M. Takahashi
MIM. Isaksson
M. Isaksson
BBB. Bravo
B. Bravo
DBDavid Broggio
David Broggio

24 April 2018 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
TBTiffany Mélanie Beaumont
Tiffany Mélanie Beaumont
MRMaeva Rimlinger
Maeva Rimlinger
DBDavid Broggio
David Broggio
PIPedro Caldeira Ideias
Pedro Caldeira Ideias
DFDidier Franck
Didier Franck
In case of nuclear accident, the internal exposure monitoring of the population will preferably focus on the detection of 131 I in the thyroid by in vivo monitoring. In most cases, the calibration of in vivo monitoring is performed with an adult thyroid phantom, which raises doubts regarding the relevance of child exposure assessment. In this study, the influence on the calibration of the thyroid volume, the counting distance and the positioning variations are studied experimentally in a systematic way. A NaI and a germanium detector along with a realistic age-specific set of four thyroid phantoms were used to carry out this study. The thyroid phantom volumes correspond to the following ages: 5, 10, 15 and adult. It was found that the counting efficiency varies linearly with the thyroid volumes for both detectors and whatever the phantom–detector distance is. The variation in counting distance strongly influences the measurement. Whatever the thyroid volume, a 30% difference in efficiency was found between the measurement at the contact and 1 cm for the NaI detector. A mathematical model giving the variation of the counting efficiency as a function of phantom–detector distance is provided. The study of positioning uncertainty has shown that the lateral/vertical displacements induce negligible efficiency variations and that it is relatively independent of the thyroid volume. The counting distance is a major parameter, which must be considered to assess the uncertainty of the subjects’ measurements. The data reported here might serve to extract useful orders of magnitude when similar detectors are used. For other detectors, a similar trend might be expected and the information provided here could reduce the amount of experimental work needed to obtain it.

25 April 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
TBT. Beaumont
T. Beaumont
POP. Onoma
P. Onoma
MRM. Rimlinger
M. Rimlinger
DBD. Broggio
D. Broggio
PIP. Caldeira Ideias
P. Caldeira Ideias
DFD. Franck
D. Franck
Age-specific thyroid phantoms corresponding to 5, 10, 15 years-old and the adult case have been designed and manufactured with a 3D printer. Reference measurements of the counting efficiency have been carried out for thyroid in vivo monitoring of 131I with all these phantoms. These measurements where performed for the emergency mobile units of IRSN. The full efficiency curve, between 29 and 1000 keV, was then obtained by Monte-Carlo calculations and validated by comparison of a large set of measurements. The obtained efficiency curves are consistent and show that the relative difference in efficiency between the adult and the children case are energy dependent.

13 March 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
TBT. Bossis
T. Bossis
MVM.-A. Verdier
M.-A. Verdier
CTC. Trigila
C. Trigila
LPL. Pinot
L. Pinot
FBF. Bouvet
F. Bouvet
LML. Ménard
L. Ménard
Molecular radiotherapy is a treatment modality that requires personalized dosimetry for efficient treatment and reduced toxicity. Current clinical imaging systems and miniaturized gamma-cameras lack the necessary features for this task. In this paper, we present the design and optimization of a mobile gamma-camera with a 10×10 cm field of view tailored for quantitative imaging during 131I therapy of thyroid diseases. The camera uses a monolithic 10×10×1 cm CeBr3 scintillator coupled to a 16×16 SiPMs array and commercial electronics. It exhibits high imaging performance with an intrinsic spatial resolution of 1.15 mm FWHM, an energy resolution of 8% FWHM at 356 keV and negligible deadtime up to 150 kcps. Images are reconstructed in real time using a convolutional neural network. The manufacturing method of tungsten collimators and shielding was optimized using laser 3D printing to achieve an effective density of 97% that of bulk tungsten. Their geometry was adjusted with Monte-Carlo simulations in order to reduce septal penetration and scattering and optimize the signal-to-noise ratio at short times after treatment administration. Two high-energy parallel-hole collimators with high sensitivity or very high spatial resolution were designed for treatment planning and post-treatment control. The fully operational gamma-camera will soon be clinically assessed.

14 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
TBT. Bossis
T. Bossis
MVM.-A. Verdier
M.-A. Verdier
LPL. Pinot
L. Pinot
FBF. Bouvet
F. Bouvet
TBT. Beaumont
T. Beaumont
LML. Ménard
L. Ménard