Benali Boutabout

Benali Boutabout

Auto-generated profile, based on publicly available information

Benali Boutabout

Laboratory of LGIDD University of Relizane, Relizane, Algeria

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2023 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
HRHadj Boulenouar Rachid
Hadj Boulenouar Rachid
DNDjebbar Noureddine
Djebbar Noureddine
BBBoutabout Benali
Boutabout Benali
Mehmet Şükrü AdinMehmet Şükrü Adin
Mehmet Şükrü Adin

1 June 2011 in Computational Materials Science
Verified
Journal Article
Closed access
FBFarida Bouafia
Farida Bouafia
BSBoualem Serier
Boualem Serier
BBBenali Boutabout
Benali Boutabout
BBBel Abbes Bachir Bouiadjra
Bel Abbes Bachir Bouiadjra

30 January 2020 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
NDNoureddine Djebbar
Noureddine Djebbar
RBRachid Hadj Boulenouar
Rachid Hadj Boulenouar
BBBenali Boutabout
Benali Boutabout
Nanostructured adhesives may be defined as those materials whose elements imbedded in an epoxy matrix have dimensions in the 1 to 100 nm range. One of the most interesting aspects of ceramic nanoparticles is that their mechanical properties depend strongly upon the particle size and shape. Silica nanoparticles (SiO2) have different physical and mechanical properties from bulk ceramics. The aim of the present study is to investigate the effect of the nanoparticles rate on the equivalent stress, peeling stress and shear stress as well as the strains developed in the adhesive joint. Three-dimensional finite element models of adhesive joint were developed to determine the stress intensity as well as strain with different nanoparticles rate in the epoxy resin. Dispersion of nanoparticles with different percent in the epoxy resin allows for reinforcing the adhesive. Polymer embedded silica nanoparticles (SiO2) proved to be highly effective.

25 February 2026 in The Saudi Dental Journal
Verified
Journal Article
Open access
PDF file
HMH. Merzouk
H. Merzouk
SHSamir Habibi
Samir Habibi
BBBen Ali Boutabout
Ben Ali Boutabout
This study aimed to evaluate cortical bone thickness of implant sites in the maxilla and mandible before & 5 months after surgery, using CBCT, to determine whether cortical bone thickness plays an important role in the Early remodeling and survival of implants under the influence of natural human chewing forces with a mixed diet, the underlying hypothesis is whether there will be changes in thickness of cortical bone after implanting due to normal chewing forces, and whether these changes will vary depending on the location of the implant in the jaw. The study started on Januray 10, 2024, in a dental clinic. It included 15 patients and 30 implant sites. All patients had two dental implants in different locations in the lower / upper jaws. The sample was divided into four groups: Group 1 anterior maxilla 4 patients, Group 2 posterior maxilla 10 patients, Group 3 anterior mandible 6 patients, and Group 4 posterior mandible 10 patients. This distribution unequal of patient’s is a limitation to generalize the study results and obtain good precision for results. Masticatory force efficiency was measured on a mixed diet for all four groups using a filtration technique for chewed foods (carrots, bread, chicken meat, etc.). The mean and percentage of masticatory efficiency were measured for all patients. The CBCT scans were performed on 0.1 mm. Cortical bone thickness was measured by taking three measurements at the implant level using a CBCT scanner and White Fox v3.1 software for all patients before and 5 months after implantation. Before implant placement, the average chewing activity rate and efficiency rate for the entire sample was 44.75%. Five months after implant placement, this increased to 60.25%, showing a 15.50% increase. The mean masticatory forces before implantation were 212.02 ± 37.94 N, which increased to 216.32 ± 29.78 N after five months, indicating an average increase of 4.3 ± 8.16 N. Regarding cortical bone thickness five months after implant placement: Posterior upper jaw (Group 2): Mean ± SD was 0.60 ± 0.36 mm. Anterior upper jaw (Group 1): Mean ± SD was 0.60 ± 0.17 mm. Anterior lower jaw (Group 3): Mean ± SD was 1.30 ± 0.51 mm. Posterior lower jaw (Group 4): Mean ± SD was 1.30 ± 0.25 mm. Statistical analysis using Student's t-test showed significant differences (p < 0.05) in cortical bone thickness between the two periods (before and 5 months after implantation) at all measurement sites. sign of the differences indicated that cortical bone thickness values were lower five months after implantation compared to before implantation. Furthermore, significant differences were found in cortical bone thickness between the three measured locations (1 mm from the implant-abutment junction radially in the apical, lingual, and buccal directions), regardless of the study period. Specifically, cortical bone thickness was smaller in the buccal direction compared to the middle of the implant radially and the apical direction. Also, thickness in the apical direction was smaller than in the lingual direction, both before and after implantation. This results at 95% confidence & p < 0.05. Chewing function improved significantly after implant placement: the average chewing activity rate increased from 44.75% before implantation to 60.25% five months after. The average chewing force also slightly increased by about 4.3 N. Statistically significant cortical bone thickness reduction (resorption) was found across all measured sites five months post-implantation (p < 0.05 and 95% confidence level). Regarding the overall thickness before and after implantation: The lower jaw (both anterior and posterior) consistently showed greater cortical bone thickness (around 1.30 mm after 5 months) compared to the upper jaw (around 0.60 mm after 5 months). The highest average cortical bone resorption (greatest reduction in thickness) occurred in the posterior upper jaw (Group 2). The lowest average cortical bone resorption occurred in the posterior lower jaw (Group 4). In terms of spatial location around the implant, the buccal (cheek side) cortical bone was generally thinner than the lingual (tongue side) and apical (root tip side) regions, both before and after implantation. This study provides valuable, quantitative data on how cortical bone thickness changes at specific implant sites over a five-month period under the influence of normal chewing forces. It confirms that CBCT is a superior tool for monitoring these changes compared to older imaging methods. Crucially, the research specifically identifies the posterior upper jaw as the region most susceptible to cortical bone resorption post-implantation, while the posterior lower jaw is the most stable. This insight directly informs clinical planning by flagging high-risk areas. Graphical Abstract

13 January 2026 in Research Journal of Pharmacy and Technology
Verified
Journal Article
Closed access
HMH. Merzouk
H. Merzouk
SHSamir Habibi
Samir Habibi
BBBenali Boutabout
Benali Boutabout
NGNoureddine Gherraf
Noureddine Gherraf
In recent years, polymers containing catechol groups—originally inspired by the adhesive proteins found in mussels—have drawn growing attention from researchers and biomaterial developers, especially for use in dentistry. These materials exhibit excellent surface adhesion due to the unique properties of catechol groups and their ability to form hydrogen bonds, making them valuable across various applications. Dopamine and its naturally occurring derivative, 3,4-dihydroxyphenylalanine (DOPA), were selected as the foundation for creating a polymerizable monomer. This was achieved through a chemical reaction with methacrylic anhydride to produce dopamine methacrylamide (DMA). The newly synthesized compound was then thoroughly analyzed using FT-IR, 1H-NMR, and 13C-NMR spectroscopy to confirm its structure. Following this, DMA was combined with ethoxylated di-GMA (EBPDMA) in different ratios to develop formulations suitable for DLP 3D printing. To create catechol-functionalized polymers, free radical polymerization was carried out in DMF using dopamine methacrylamide and methyl methacrylate (MMA). The resulting cross-linked polymer networks were analyzed using gel permeation chromatography (GPC), along with FT-IR and 1H-NMR techniques, to better understand their structural characteristics. Finally, the mechanical performance of the developed materials was assessed through a series of tests, including measurements of compressive strength, flexural strength, and hardness, all conducted using a universal testing machine (UTM).