1 April 2014 in Advanced Materials Research
Repairing and strengthening the structures are gaining more attention from many researchers and structural engineers after the structures suffered damages from natural disasters. Tunnel form RC buildings which are not designed according to seismic code of practice are very vulnerable to ground motion when located to near field earthquake. This paper presents the method of repair and strengthening of 3-storey tunnel form building subjected to in-plane lateral cyclic loading. The building was strengthened using the combination method of steel angle, steel plate and Carbon Fiber Reinforce Polymer (CFRP) sheet. The results show that the lateral strength capacity is increase by 15.66%, ductility increase by 53.57% and equivalent viscous damping increase by 28.88% for the first cycle and 33.65% for the second cycle. However, the stiffness of the structure reduce by 56.6%. It can be concluded that this method can be adopted for the damage of tunnel form building system.
3 June 2014 in Computers in Railways XIV
The seismic performance of one-third scale double units three-storey tunnel form reinforced concrete building tied up with foundation beam tested...
1 October 2014 in Applied Mechanics and Materials
Tunnel form construction is widely known as modern construction method that enables the construction of horizontal and vertical elements simultaneously. It is quickly construct low cost, high quality and earthquake safe to construct cellular buildings. Main objective of this study is to determine the seismic retrofitting performance of a double unit tunnel form building when retrofitted using additional RC wall, steel angle and Carbon Fiber Reinforced Polymer (CFRP) when tested under in-plane lateral cyclic loading. A comparison of tunnel form building was made before and after retrofitting in terms of lateral strength, stiffness, ductility and equivalent viscous damping. Result indicates that retrofitting method using additional RC wall, steel angle and CFRP was able to increase the lateral strength, ductility and equivalent viscous damping under in-plane lateral cyclic loading. The result also shows the effectiveness of additional RC wall, steel angle and CFRP in improving the shear resistances and deformation capacities of concrete structures and delaying their stiffness degradation under earthquake loading.
1 November 2022 in Civil Engineering Journal
Most of the high-rise buildings for commercial and residential purposes in Malaysia are constructed using a tunnel formwork system. This type of building becomes a favor due to the fast construction and cost-effectiveness. However, the research on the behavior of Tunnel Form Building (TFB) under the seismic effect is still insufficient and requires further investigation. Therefore, the safety level of double unit TFB subjected to weak plane (out-of-plane) was investigated in this study. The TFB was designed using a non-seismic provision to represent an existing condominium building constructed in Selangor. Ten past earthquake records categorized as major, moderate, and low magnitudes were utilized. The behavior of the double unit TFB was analyzed using the Ruaumoko 2D program. The ultimate lateral load, displacement, pseudo-spectral acceleration (PSA), pseudo-spectral displacement (PSD), and mode shape of TFB were also analyzed. Based on the findings, most of the selected earthquake records exceeded the lateral capacity of TFB. The building experienced a major damage under 6.9 Richter scale of Imperial Valley, 7.3 Richter scale of San Joaquin Valley, and 7.9 Richter scale of Denali Earthquakes excitations. Therefore, these findings suggested if any similar magnitudes of unpredicted seismic events would occur in the future, significant damages may be experienced by the existing TFB in Malaysia. Doi: 10.28991/CEJ-2022-08-11-012 Full Text: PDF
1 October 2014 in Applied Mechanics and Materials
A one-third scale single unit of 3-storey tunnel form building with foundation beam was designed, constructed and tested under out-of-plane lateral cyclic loading. This building was designed according to BS8110 with no provision for seismic loading. Tunnel form building was initially tested at ±0.01% , ±0.1%, ±0.25%, ±0.5%, ±0.75%, ±1.00%, ±1.25% and ±1.5% drifts until the structure lost its lateral strength (strength degradation). Then, the specimen was repaired and retrofitted using steel plate and angle which was positioned at the wall-slab joints that had suffered severe damages. A similar drift of displacement before retrofitting was repeated for the specimen after being retrofitted. Visual observation of damages, hysteresis loops, stiffness, ductility and equivalent viscous damping (EVD) of the specimen were analyzed and compared before and after retrofitting. The proposed retrofitting technique has increased its lateral strength by 26%. Fewer cracks occurred after retrofitting the specimen compared to before retrofitting. It can be concluded that steel plate and angle can strengthen the wall-slab joint and this method can be used to retrofit the tunnel form building if it had been damaged caused by earthquake excitations.
1 January 2023 in AIP Conference Proceedings
Sugar cane is main food crop in tropical and subtropical countries. It is the main resource for the sugar production. Sugar cane bagasse (SCB) is a waste that produced after the juice extraction of sugarcane while sugar cane bagasse ash (SCBA) produced after the control burning of SCB. The use of waste products as partial replacement for the material in concrete can help to reduce the environmental and economic problem. Since the cost of construction materials such as cement is increasing spirally and agricultural waste such as SCBA can be obtained at low cost, it has a good potential to use in concrete as cement replacement. In this study, the workability, density, and compressive strength of the concrete been chosen to compare with the green concrete. Three different types concrete cube have been casted in this study, na1111mely; 0, 5%, 7.5%, 10% of SCBA to replace for cement. The size of the cube samples to be casted is 100 x 100 x 100 mm and cured for 7 and 28 days. The study show that the optimum percentage for SCBA concrete is 5%, it give the highest compressive strength value compare to other percentage at 28 days.