Martina Pulcinelli

Martina Pulcinelli

Auto-generated profile, based on publicly available information

Martina Pulcinelli

Department of Engineering, Unit of Measurements and Biomedical Instrumentation, Universit Campus Bio-Medico di Roma, Rome, Italy

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2025 in APL Photonics
Verified
Journal Article
Open access
MPMartina Pulcinelli
Martina Pulcinelli
ICIlaria Condò
Ilaria Condò
VLVincenzo Lavorgna
Vincenzo Lavorgna
CMCarlo Massaroni
Carlo Massaroni
Emiliano SchenaEmiliano Schena
Emiliano Schena
DPDaniela Lo Presti
Daniela Lo Presti
Healthcare has rapidly evolved in the last decades, driven by the demand for personalized therapies and advancements in enabling technologies. Among many solutions, fiber Bragg grating (FBG) sensors have gained significant acceptance in the medical field, due to their good static and dynamic performance, small dimensions, biocompatibility and immunity to electromagnetic interferences. The integration of artificial intelligence (AI) with FBGs is emerging as a breakthrough approach, enabling the design of smart systems for medical applications, like minimally invasive surgery, physiological monitoring, biomechanics, and medical biosensing. These systems harness the potential of FBGs and the advanced data processing capabilities of AI to improve diagnostics and therapeutic procedures. This perspective provides an overview of the sensing systems that combine FBG and AI technologies in medicine, focusing on their working principle, potentials, and challenges. It also explores the open research directions for encouraging further investigations in this field.

9 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VLVincenzo Lavorgna
Vincenzo Lavorgna
AAAndrea Addabbo
Andrea Addabbo
ADAlfredo Dimo
Alfredo Dimo
Umile Giuseppe LongoUmile Giuseppe Longo
Umile Giuseppe Longo
MPMartina Pulcinelli
Martina Pulcinelli
Emiliano SchenaEmiliano Schena
Emiliano Schena
In recent years, wearable devices for monitoring physiological and biomechanical parameters have gained increasing attention, particularly for assessing individuals suffering from back pain. This condition can influence respiratory rate (RR) and heart rate (HR), making their continuous, noninvasive monitoring valuable for back pain mitigation strategies. Fiber Bragg grating (FBG) sensors are well suited for wearable sensing due to their flexibility, multiplexing capability, and biocompatibility, although their fragility remains a limitation. A promising solution involves integrating FBG sensors into 3-D-printed components, a technique that offers cost-effectiveness, ease of fabrication, and high reproducibility. In particular, the fused deposition modeling (FDM) technique enables the fabrication of components using two distinct materials, to combine the specific advantages of each material. Despite the potential of dual-material 3-D printing technology, this approach is still underexplored in the scientific literature. This study presents the design and fabrication of two identical wearable sensors (WSs) based on FBG technology manufactured using FDM. The novelty is to combine the benefits of two materials: thermoplastic polyurethane (TPU), to enhance the sensors’ strain response, and polylactic acid (PLA), to provide greater rigidity in the anchoring region to the human body. This solution allowed optimizing the static and dynamic performance of the sensors. In addition, preliminary tests on healthy subjects highlighted the capability of the proposed systems to monitor cardio-respiratory activity (in particular RR and HR) and flexion-extension movements of the back.

26 June 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
MPM. Pulcinelli
M. Pulcinelli
LZL. Zoboli
L. Zoboli
Francesca De TommasiFrancesca De Tommasi
Francesca De Tommasi
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
VAV. Altomare
V. Altomare
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Superficial tissue palpation is a clinical examination to detect tumors in soft tissue, like breast, by applying variable forces on its surface. Recently, instrumented tactile probes based on different technologies (e.g., electrical and optical sensors) were developed to quantitatively detect changes in the tissue stiffness, improving the chances of early tumor diagnosis. Among many options to develop tactile probes, fiber Bragg grating (FBG) sensors are gaining increasing traction, thanks to their superior potentials (e.g., high sensitivity, small dimensions, electromagnetic immunity interferences, and multiplexing capability). This study proposed a multi-FBG sensors tactile system for superficial breast palpation, as an optimization of a previously designed prototype, in terms of dimensions and number of sensors. It represents the first step towards the creation of a matrix of sensors for optimizing the tumor identification. In details, a three-FBG array was integrated into a 3Dprinted structure to simultaneously investigate multiple measurement sites, enhance the system spatial resolution, and minimize the probe encumbrance. The design of the system was guided by a finite element analysis. Then, a metrological characterization was performed, focusing on the investigation of the FBGs sensitivity to force and analysis of the crosstalk effects among sensors within the same structure. Subsequently, palpation tests on phantoms mimicking soft tissues with a tumor were conducted, revealing the ability of the fabricated system to detect stiffer materials within flexible substrates. These findings make the proposed system an ideal candidate for diagnostic tissue palpation.

6 August 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
VLV. Lavorgna
V. Lavorgna
MPM. Pulcinelli
M. Pulcinelli
GGG. Gabriele
G. Gabriele
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Despite the growing adoption of minimally invasive surgery (MIS), the absence of effective sensory feedback for surgeons during tissue manipulation, particularly regarding the applied gripping force (F), remains a major limitation, increasing the risk of unintentional tissue damage. This study presents the development of a sensorized forceps that combines the advantages of fiber Bragg grating (FBG) sensors (e.g., compact size and excellent metrological performance) and Fused Deposition Modeling (FDM) (e.g., rapid prototyping and the use of different materials adapted to specific functions) for enhanced F feedback in MIS surgery. A sensing element was developed in 3D-printed thermoplastic polyurethane, hosting an array of three FBGs suspended within a bridge-shaped structure to convert axial strain, generated by transverse loading during tissue gripping, into a measurable estimation of gripping F. Additionally, a fourth FBG was encapsulated in a silicone matrix and placed in a strain-free zone of the lower jaw to compensate temperature variations (ΔT). The MIS forceps prototype itself was entirely fabricated via FDM using polylactic acid. Metrological characterization revealed F sensitivities of 0.13 nm/N, 0.15 nm/N, and 0.21 nm/N for the three FBGs of the array in the 0 N – 2 N range, and a T sensitivity of 0.015 nm/°C for the sensor used for T compensation. Finally, preliminary tests on ex-vivo porcine organs demonstrated that the proposed system enhances gripping stability in the presence of real-time F feedback, confirming its potential for improving intraoperative F awareness in MIS procedures.

11 June 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MPMartina Pulcinelli
Martina Pulcinelli
FDFederico D'Antoni
Federico D'Antoni
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Emiliano SchenaEmiliano Schena
Emiliano Schena
CMCarassiti Massimiliano
Carassiti Massimiliano
Mario MeroneMario Merone
Mario Merone
Objective: Loss of resistance (LOR) is a widely accepted method for performing epidural punctures in clinical settings. However, the risk of failure associated with LOR is still high. Solutions based either on Fiber Bragg grating sensors (FBG) or on artificial intelligence (AI) are gaining ground for supporting clinicians during this kind of procedure. Here, for the first time, we combined the mentioned two technologies to perform an AI-driven LOR identification based on data collected by a custom FBG sensor. Methods: This study presented two contributions (i.e., automatic labeling and identification) based on machine learning to support epidural procedures by enhancing LOR detection. The methods were tested using data collected by a customized FBG-based flexible cap on 10 patients affected by chronic back pain. Results: The automatic labeling can retrospectively identify every LOR event for each subject under consideration. This serves as the labeling for the automatic identification task, which emulates the real-time application of LOR detection. A Support Vector Machine, trained using a Leave-One-Out strategy, demonstrates high accuracy in identifying all LOR events while maintaining a minimal rate of false positives. Conclusion: Our findings revealed the promising performance of the proposed AI-based approach for automatic LOR detection. Thus, their combination with FBG technology can potentially improve the level of support offered to clinicians in this application. Significance: The integration of AI and FBG technologies holds the promise of revolutionizing LOR detection, reducing the likelihood of unsuccessful epidural punctures and advancing pain management.

3 March 2026 in IEEE Sensors Journal
Verified
Journal Article
Open access
VLV. Lavorgna
V. Lavorgna
MPM. Pulcinelli
M. Pulcinelli
ECE. Crispi
E. Crispi
VTV. Tomarchio
V. Tomarchio
Emiliano SchenaEmiliano Schena
Emiliano Schena
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Manual palpation is a diagnostic procedure commonly used to assess tissue stiffness and to detect abnormal masses such as lesions or enlarged lymph nodes. In this context, monitoring the force (F) exerted during the contact between the clinician’s fingers and the patient’s body can provide quantitative information to support clinical evaluation, reducing subjectivity and improving diagnostic reproducibility. This study presents a soft wearable device (SWD) designed to be worn on the clinician’s index finger for real-time monitoring of F during palpation. The system integrates a fiber Bragg grating (FBG) optical sensor, particularly suitable for this application due to its compactness, flexibility and high metrological performance. The SWD was fabricated using a skin-safe soft silicone matrix to ensure comfort and preserve the clinician’s natural tactile perception. Following the fabrication, the system underwent metrological characterization to evaluate its response to known F variations. Results showed a quasi-linear relationship between the SWD output (ΔλB) and F in the 0 N – 6 N range, typical of manual palpation, with a sensitivity of 0.040 nm/N and excellent repeatability under loading-unloading cycles. Finally, a real palpation test was carried out by a clinical operator on three healthy volunteers to assess the device performance under realistic conditions. The device provided stable and repeatable responses consistent with the applied F, with clear signal transitions corresponding to the onset and release of palpation. The clinician reported no perceptible alteration of tactile feedback, confirming the comfort, stability, and practical usability of the SWD during real palpation tasks.