28 August 2024 in Journal of Synchrotron Radiation
Small-angle-scattering tensor tomography is a technique for studying anisotropic nanostructures of millimetre-sized samples in a volume-resolved manner. It requires the acquisition of data through repeated tomographic rotations about an axis which is subjected to a series of tilts. The tilt that can be achieved with a typical setup is geometrically constrained, which leads to limits in the set of directions from which the different parts of the reciprocal space map can be probed. Here, we characterize the impact of this limitation on reconstructions in terms of the missing wedge problem of tomography, by treating the problem of tensor tomography as the reconstruction of a three-dimensional field of functions on the unit sphere, represented by a grid of Gaussian radial basis functions. We then devise an acquisition scheme to obtain complete data by remounting the sample, which we apply to a sample of human trabecular bone. Performing tensor tomographic reconstructions of limited data sets as well as the complete data set, we further investigate and validate the missing wedge problem by investigating reconstruction errors due to data incompleteness across both real and reciprocal space. Finally, we carry out an analysis of orientations and derived scalar quantities, to quantify the impact of this missing wedge problem on a typical tensor tomographic analysis. We conclude that the effects of data incompleteness are consistent with the predicted impact of the missing wedge problem, and that the impact on tensor tomographic analysis is appreciable but limited, especially if precautions are taken. In particular, there is only limited impact on the means and relative anisotropies of the reconstructed reciprocal space maps.
3 December 2024 in Acta Biomaterialia
Physical exercise has been shown to induce positive reactions in bone healing but next to nothing is known about how it affects the nanostructure, in particular around implants. In this study, we established this link by using small-angle X-ray scattering tensor tomography (SASTT) to investigate nanostructural parameters in 3D such as mineral particle orientation and thickness. As a model system, rat femoral bone with a bio-resorbable implant (ultra-high purity magnesium) was used. One half of the rats underwent treadmill exercise while the other half were moving freely in a cage. At two- and six-weeks post-surgery rats were sacrificed, and samples were taken. Our results point to an earlier start and stronger remodeling when physical exercise is applied and to a stronger reorientation of the mineralized collagen fibers around the implant. This study reveals the nanostructural response of bone with bio-resorbable implants to physical exercise. Understanding this response is very important for designing post-surgery treatments. STATEMENT OF SIGNIFICANCE: Physical exercise is known to have beneficial effects on the human body and is often incorporated into the recovery process following orthopedic surgeries. While the response of bone to physical exercise is well-documented, the structural response of bone to early exercise after implant placement, particularly its impact on the nanostructure, has not been extensively studied. In this study, we identify the effects of physical exercise on the bone nanostructure and the remodeling process around a bioresorbable implant. These findings could help develop tailored physical exercise strategies for post-surgery recovery in patients.
14 April 2026 in Journal of Synchrotron Radiation
Scanning small-angle X-ray scattering (sSAXS) has found multiple applications as a technique to probe the nanostructure in soft tissues and pathologies thereof. However, fresh tissue is fragile and prone to the quick onset of decomposition and autolysis. It lacks the firmness required for uniform and thin sectioning, resulting in the loss of 2D resolution offered by focused X-ray beams, because the signal would be integrated through thick and/or irregular sections. Tissue processing, that includes fixation and embedding, is used to mitigate these issues but can by itself introduce structural changes in the tissues and impede the correct interpretation of sSAXS data. Here the extent of these structural changes in the SAXS signal caused by common tissue preservation methods on the example of skeletal muscle tissue, consisting of both muscle and surrounding connective tissue, was studied. This can guide an informed choice of preservation method tailored for specific experimental requirements. While some techniques performed better than others, all tissue-processing methods induced structural changes to a certain degree. The choice of preservation method is therefore a balance between sectioning requirements and type of tissue used, as well as targeted structural information.
20 June 2026 in Small Science
Pathological ossification is seen affecting different organs across the body. This includes the Achilles tendon, where the healing process after rupture can be impaired by heterotopic ossifications (HO). The formation pathways for HO in tendons are still debated, and one reason for this is our limited knowledge of their structure and composition in 3D. This study utilizes a multimodal 3D characterization approach to study HO and the surrounding healing tissue at 3‐, 6‐, and 12‐week post‐transection in rat Achilles tendons. Microcomputed tomography provided 3D microstructural information. Small‐ and wide‐angle scattering tensor tomography contributed with combined collagen and hydroxyapatite (HA) 3D nanostructural information. Combined 3D X‐ray diffraction and fluorescence provided high‐resolution structural dimensions of HA crystallites, and chemical composition of both the deposits and the surrounding healing tendon tissue. Morphologically, dense mineralized tissue appeared more fibrous, with higher co‐localized quantities of Zn present internally, while porous regions of HO deposits had Zn localization primarily at the boundary. Collagen d‐spacing was higher within HO deposits than in the surrounding collagenous tendon tissue. Collagen misalignment close to the HO boundary supports the notion of tissue mineralization occurring prior to the full assembly of the healing tendon network. This methodology can be extrapolated to investigate pathological ossification in other tissues at the nanoscale while capturing the heterogeneity of entire specimens.
30 October 2026 in bioRxiv
In this study, we used synchrotron radiation micro-computed tomography (SR-µCT) to investigate the effect of early post-operative physical exercise at 2, 4, and 6 weeks on osteo-cyte lacunar distribution and morphology in a Sprague Dawley rat femoral defect model after implantation of a bioresorbable pin. Physical exercise has been shown to improve bone re-modeling after fracture, but its effects on the lacuno-canalicular network in the presence of bioresorbable implants remain unclear. The structure of lacunae is linked to that of osteocytes, which play an important role in bone remodeling and adaptation to stress. We studied a large number of lacunae (around 670 000 per sample) in terms of their location, morphology, and orientation. We show that in newly formed bone, lacunae are larger and rounder with exercise, while in previously existing bone, lacunae are less oriented along the long bone axis when exercise is performed. In addition, close to the implant, lacunar density is higher with exercise in both newly formed bone and previously existing bone. These findings point to a higher degree of remodeling and a pronounced lacunar response to mechanical stimulation and may thus help clarify bone behavior with exercise around implants to better design post-surgical recovery treatments.