John K. Liu

John K. Liu

Auto-generated profile, based on publicly available information

John K. Liu

Jet Propulsion Lab. (United States)

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2010 in IEEE Journal of Quantum Electronics
Verified
Journal Article
Closed access
SGSarath D. Gunapala
Sarath D. Gunapala
SBSumith V. Bandara
Sumith V. Bandara
JLJohn K. Liu
John K. Liu
JMJason M. Mumolo
Jason M. Mumolo
DTDavid Z. -Y. Ting
David Z. -Y. Ting
MTMeimei Z. Tidrow
Meimei Z. Tidrow
Quantum well infrared photodetectors (QWIPs) are well known for their stability, high pixel-pixel uniformity and high pixel operability which are quintessential parameters for large area imaging arrays. In this paper we report the first demonstration of the megapixel-simultaneously-readable and pixel-co-registered dual-band QWIP focal plane array (FPA). The dual-band QWIP device was developed by stacking two multi-quantum-well stacks tuned to absorb two different infrared wavelengths. The full width at half maximum (FWHM) of the midwave infrared (MWIR) band extends from 4.4-5.1 ¿m and FWHM of the long-wave infrared (LWIR) band extends from 7.8-8.8 ¿m. Dual-band QWIP detector arrays were hybridized with direct injection 30 ¿m pixel pitch megapixel dual-band simultaneously readable CMOS read out integrated circuits using the indium bump hybridization technique. The initial dual-band megapixel QWIP FPAs were cooled to 68 K operating temperature. The preliminary data taken from the first megapixel QWIP FPA has shown system NE¿T of 27 and 40 mK for MWIR and LWIR bands, respectively.

5 April 2012 in IEEE Journal of Quantum Electronics
Verified
Journal Article
Closed access
SRSir B. Rafol
Sir B. Rafol
ASAlexander Soibel
Alexander Soibel
AKArezou Khoshakhlagh
Arezou Khoshakhlagh
JNJean Nguyen
Jean Nguyen
JLJohn K. Liu
John K. Liu
SGSarath D. Gunapala
Sarath D. Gunapala
Long-wavelength complementary barrier infrared detector (CBIRD) based on III-V material is hybridized to recently designed and fabricated 320 × 256 pixel format two-color read-out integrated circuit. The n-type CBIRD is characterized in terms of performance and thermal stability. This paper reports on the measured dark current density, noise equivalent difference temperature, quantum efficiency, responsivity, minimum resolvable difference temperature, and modulation transfer function.

22 July 1998
Verified
Conference Paper
Closed access
SGSarath D. Gunapala
Sarath D. Gunapala
SBSumith V. Bandara
Sumith V. Bandara
ASAnjali Singh
Anjali Singh
JLJohn K. Liu
John K. Liu
ELEdward M. Luong
Edward M. Luong
MMM. J. McKelvey
M. J. McKelvey
High performance long-wavelength GaAs/AlxGa1-xAs quantum well infrared photodetectors for low background applications have been demonstrated. This is the first theoretical analysis of quantum well infrared photodetectors for low background applications and the detectivity D* of 6 X 1013 cm(root)Hz/W has been achieved at T equals 40 K with 2 X 109 photons/cm2/sec background. In addition, this paper describes the demonstration of mid- wavelength/long-wavelength dualband quantum well infrared photodetectors and long-wavelength/very long-wavelength dualband quantum well infrared photodetectors in 4 - 26 micrometer wavelength region.

12 November 2003
Verified
Conference Paper
Closed access
SGSarath D. Gunapala
Sarath D. Gunapala
SBSumith V. Bandara
Sumith V. Bandara
JLJohn K. Liu
John K. Liu
SRSir B. Rafol
Sir B. Rafol
JMJason M. Mumolo
Jason M. Mumolo
A 640×512 pixel, long-wavelength cutoff, narrow-band (Δλ/λ~10%) quantum well infrared photodetector (QWIP) focal plane array (FPA), a four-band QWIP FPA in the 4-15 μm spectral region, and a broad-band (Δλ/λ~42%) QWIP FPA having a 15.4 μm cutoff have been demonstrated. In this paper, we discuss the electrical and optical characterization of these FPAs, and their performance. In addition, we discuss the development of a very sensitive (NEDT~~10.6 mK) 640×512 pixel thermal imaging camera having a 9 μm cutoff.

13 August 1997
Verified
Conference Paper
Closed access
SGSarath D. Gunapala
Sarath D. Gunapala
TKTimothy N. Krabach
Timothy N. Krabach
SBSumith V. Bandara
Sumith V. Bandara
JLJohn K. Liu
John K. Liu
MSMani Sundaram
Mani Sundaram
A 9 micrometer cutoff 256 by 256 hand-held quantum well infrared photodetector (QWIP) camera has been demonstrated. Excellent imagery, with a noise equivalent differential temperature (NE(Delta) T) of 26 mK has been achieved. In this paper, we discuss the performance of this portable long- wavelength infrared camera in quantum efficiency, NE(Delta) T, minimum resolvable temperature difference (MRTD), uniformity, etc., and its applications in science, medicine and defense.

27 July 2012 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
JNJean Nguyen
Jean Nguyen
ASAlexander Soibel
Alexander Soibel
SRSir B. Rafol
Sir B. Rafol
AKArezou Khoskhlagh
Arezou Khoskhlagh
JLJohn K. Liu
John K. Liu
SGSarath D. Gunapala
Sarath D. Gunapala
We report on the details of inductively coupled plasma etching for achieving low dark current long-wavelength infrared focal plane arrays (FPAs). External factors that influence the etching process are studied. A high-quality hard mask for excellent pattern transfer is discussed. Next, a suitable mounting technique for good thermal contact is described. Finally, the challenges and differences between etching large 200-μm test diodes and small 28-μm FPA pixels are discussed. The complete etching process is then demonstrated on a 320 × 256 complementary barrier infrared detector FPA. The mean dark current density of 2.2 × 10-4A/cm2 is measured at an operating bias of 128 mV with a 50% cutoff wavelength of 8.8 μm. Good imagery is achieved with an array yielding an 81% fill factor with 97% operability. Operating at T = 80 K, the measured mean noise equivalent differential temperature is 18.6 mK, and the mean detectivity is D* = 1.3 × 1011cm-Hz1/2/W.