5 October 2016 in Bulletin of Chemical Reaction Engineering & Catalysis
This paper presents a characterization of an integrated ozone generator constructed by seven of reactors of Dielectric Barrier Discharge Plasma (DBDP). DBDP a has spiral-cylindrical configuration. Silence plasma produced ozone inside the DBDP reactor was generated by AC-HV with voltage up to 25 kV and maximum frequency of 23 kHz. As a source of ozone, dry air was pumped into the generator and controlled by valves system and a flowmeter. We found ozone concentration increased with the applied voltage, but in contrary, the concentration decreased with the flow rate of dry air. It was also found that a maximum concentration was 20 mg/L and ozone capacity of 48 g/h with an input power of 1.4 kW. Moreover, in this generator, IP efficiency of 8.13 g/kWh was obtained at input power 0.45 kW and air flow rate of 9 L/min. Therefore, be the higher ozone capacity can be produced with higher input power; however, it provided lower IP efficiency. The effect of dry air flow rate and applied voltage on ozone concentrations have been studied. At last, spiral wire copper was very corrosive done to the interaction with ozone, and it is necessary to do a research for finding the best metals as an active electrode inside of the quartz dielectric.
1 May 2019 in Journal of Physics: Conference Series
Ozone that was generated by using dielectric barrier discharge plasma (DBDP) reactor has been investigated. In this study, we compared ozone production with reactor series and parallelled at atmospheric pressure. The reactor used models of a wire mesh - aluminum foil configuration. The first reactor uses a series circuit with two reactors and the second reactor uses a parallel circuit with two reactors. Ozone was produced by DBDP reactor using AC high Voltage. Oxygen that source of ozone has been taken from the pure oxygen and natural gas. Some analysis conducted including the variation of voltage, the flow rate of gas and type of source gas which affect produced concentration. Some parameters varied including voltage from 0 - 10 kV and the flow rate of gas 4 - 12 L / min. The results showed that ozone concentration in the series reactor is higher than that of the parallel reactor. The series reactor could produce ozone with a concentration of 348 ppm at a voltage of 10 kV. Then the parallel reactor of ozone could produce with a concentration of 240 ppm at a voltage of 10 kV. We found that series reactor could produce more high ozone concentration at the same voltage.
1 November 2016 in Journal of Physics: Conference Series
An atmospheric of argon plasma jet was generated by using column dielectric barrier discharge has been investigated. In this study, argon gas was passed through the capillary column by regulating the flow rate of gas. This atmospheric pressure plasma jet (APPJ) was generated by a sinusoidal AC high voltage in the range of 0.4 kV to 10 kV and at frequencies of 15 kHz and 26 kHz. APPJ has been produced with flow rate of argon gas from 1 litter/min-10 litters/min. The electric current has been taken with variation of voltage and each interval argon gas flow rate of 1 litter/min. The results show that electric current increase linearly and then it trends to saturation condition by the increasing of applied voltage. We found also that the length of the plasma jet increase by augmenting of applied voltage both for frequencies of 15 kHz and 26 kHz. Furthermore, our results show that length of plasma jet optimum for flow rate of argon gas of 2 litters/minute. In addition, we obtained that the larger applied voltage, the greater the temperature of the plasma jet.
1 January 2017 in Procedia Engineering
12 September 2018 in MATEC Web of Conferences
Plasma-activated medium (PAM) has been produced by exposing a liquid media to Argon plasma jet. The jet plasma exposure to liquid media has produced reactive Oxygen species (ROS) in liquid phase. This study aims to determine the number of reactive species in plasma-activated medium. An atmospheric pressure plasma jet (APPJ) was generated with a dielectric barrier discharge (DBD) column by AC high voltage. Some parameters varied including exposure time; i.e. 5, 10, 15, 20, 25, and 30 min; and the distance between reactor and active media; i.e. 1, 2 and 3 cm. Some analysis conducted including variation of exposure times, the distances of reactor to PAM which affect produced concentration, and the reactive species composition in plasma-activated medium. In addition, temperature characteristics, pH levels, dissolved ozone and dissolved hydrogen peroxide concentrations were also observed in this study. The results showed that increased exposure time resulted in decreased pH, increased temperature and increased concentrations of ozone and hydrogen peroxide. The maximum reactive species composition was obtained at the distance between reactor and plasma-activated medium of 2 cm. Maximum reactive species composition obtained in this study has temperature of 29-30 Celsius degrees; pH 3.5; dissolved ozone 2.97 ppm; and Hydrogen Peroxide 215 ppm.
12 September 2018 in MATEC Web of Conferences
Ozone has been used to extend the shelf life of vegetables by inhibiting the decomposing microbial growth. The study was conducted using six types of vegetables; i.e. broccoli, tomato, mustard, celery, leek, and lettuce; treated and stored using ozonation techniques. The six types of vegetables were divided into two treatment groups, i.e. ozone-washed and not washed, and stored in ozone-filled cold storage at a dose of 15 gr/m3 per day. Total microbial testing was performed to determine the number of microbes in each vegetable sample. In addition, proximate testing was performed to observe the decreasing rate in nutrient content during storage time. The results showed that ozone-washed tomatoes is the most durable varieties which can stay fresh until day-12 with TPC and YMC values of 4.8x105 CFU/g and 13x105 CFU/g respectively. While the control tomato has a TPC and YMC value of 2.0x106 CFU/g and 85x106 CFU/g respectively. In addition, the proximate test results showed that the nutrient content in each ozone-washed samples didn't decrease significantly compared with the control samples. These results indicate that ozone-washing treatment can extend the shelf life of vegetables while still maintaining their nutritional value.