Muhammad  Nur

Prof. Muhammad Nur


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
UCU Chasanah
U Chasanah
EYEko Yulianto
Eko Yulianto
AZA Z Zain
A Z Zain
ESE Sasmita
E Sasmita
MRM Restiwijaya
M Restiwijaya
MNMuhammad Nur
Muhammad Nur

5 October 2016 in Bulletin of Chemical Reaction Engineering & Catalysis
Verified
Journal Article
Open access
PDF file
MNMuhammad Nur
Muhammad Nur
ASAde Ika Susan
Ade Ika Susan
ZMZaenul Muhlisin
Zaenul Muhlisin
FAFajar Arianto
Fajar Arianto
AKAndi Wibowo Kinandana
Andi Wibowo Kinandana
AUAnwar Usman
Anwar Usman
This paper presents a characterization of an integrated ozone generator constructed by seven of reactors of Dielectric Barrier Discharge Plasma (DBDP). DBDP a has spiral-cylindrical configuration. Silence plasma produced ozone inside the DBDP reactor was generated by AC-HV with voltage up to 25 kV and maximum frequency of 23 kHz. As a source of ozone, dry air was pumped into the generator and controlled by valves system and a flowmeter. We found ozone concentration increased with the applied voltage, but in contrary, the concentration decreased with the flow rate of dry air. It was also found that a maximum concentration was 20 mg/L and ozone capacity of 48 g/h with an input power of 1.4 kW. Moreover, in this generator, IP efficiency of 8.13 g/kWh was obtained at input power 0.45 kW and air flow rate of 9 L/min. Therefore, be the higher ozone capacity can be produced with higher input power; however, it provided lower IP efficiency. The effect of dry air flow rate and applied voltage on ozone concentrations have been studied. At last, spiral wire copper was very corrosive done to the interaction with ozone, and it is necessary to do a research for finding the best metals as an active electrode inside of the quartz dielectric.

6 July 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
ASA I Susan
A I Susan
MWMohamad Widodo
Mohamad Widodo
MNMuhammad Nur
Muhammad Nur
The effects of irradiation by a corona glow discharge plasma on hidrophylicity properties of polyester and cotton fabrics were investigated. We used a corona glow discharge plasma reactor with multiple points to plane electrodes, which was generated by a high voltage DC. Factors that affect the hidrophylicity properties were identified and evaluated as functions of irradiation parameters, which include duration of treatment, distance between electrodes, and bias voltage. It was readily observed from SEM examinations that plasma changed the surface morphology of both polyester and cotton fibers, giving result to an increased roughness to both of them. Results also showed that the hidrophylicityof polyester and cotton fabrics improved by the treatment, which is proportional to the time of treatment and voltage, but inversely proportional to the distance between electrodes. Time of treatment that provided the optimum enhancement of hidrophylicity for cotton is 15 minutes which improved the wetting time from 8.16 seconds to 1.26 seconds. For polyester, it took 15 minutes of irradiation time to improve the wetting time from 7340 seconds to 2905 seconds. The optimum distance between electrodes for both fabrics in this study was found to be 2 cm. Further analysis showed that the improved hidrophylicity properties is due to the creation of surface radicals by free radicals in the plasma leading to the formation of new water-attracting functional groups on the fiber surface.

1 November 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
MNMuhammad Nur
Muhammad Nur
AKA. W. Kinandana
A. W. Kinandana
PWP. Winarto
P. Winarto
ZMZ. Muhlisin
Z. Muhlisin
NNN Nasruddin
N Nasruddin
An atmospheric of argon plasma jet was generated by using column dielectric barrier discharge has been investigated. In this study, argon gas was passed through the capillary column by regulating the flow rate of gas. This atmospheric pressure plasma jet (APPJ) was generated by a sinusoidal AC high voltage in the range of 0.4 kV to 10 kV and at frequencies of 15 kHz and 26 kHz. APPJ has been produced with flow rate of argon gas from 1 litter/min-10 litters/min. The electric current has been taken with variation of voltage and each interval argon gas flow rate of 1 litter/min. The results show that electric current increase linearly and then it trends to saturation condition by the increasing of applied voltage. We found also that the length of the plasma jet increase by augmenting of applied voltage both for frequencies of 15 kHz and 26 kHz. Furthermore, our results show that length of plasma jet optimum for flow rate of argon gas of 2 litters/minute. In addition, we obtained that the larger applied voltage, the greater the temperature of the plasma jet.

1 November 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
MNMuhammad Nur
Muhammad Nur
MRM. Restiwijaya
M. Restiwijaya
ZMZ. Muchlisin
Z. Muchlisin
ISI. A. Susan
I. A. Susan
FAF. Arianto
F. Arianto
SWS. A. Widyanto
S. A. Widyanto
Studies on the consumption of energy by an ozone generator with various constructions electrodes of dielectric barrier discharge plasma (DBDP) reactor has been carried out. This research was done to get the configuration of the reactor, that is capable to produce high ozone concentrations with low energy consumption. BDBP reactors were constructed by spiral- cylindrical configuration, plasma ozone was generated by high voltage AC voltage up to 25 kV and maximum frequency of 23 kHz. The reactor consists of an active electrode in the form of a spiral-shaped with variation diameter Dc, and it was made by using copper wire with diameter Dw. In this research, we variated number of loops coil windings N as well as Dc and Dw. Ozone concentrations greater when the wire's diameter Dw and the diameter of the coil windings applied was greater. We found that impedance greater will minimize the concentration of ozone, in contrary to the greater capacitance will increase the concentration of ozone. The ozone concentrations increase with augmenting of power. Maximum power is effective at DBD reactor spiral-cylinder is on the Dc = 20 mm, Dw = 1.2 mm, and the number of coil windings N = 10 loops with the resulting concentration is greater than 20 ppm and it consumes energy of 177.60 watts

26 February 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
EYEko Yulianto
Eko Yulianto
IZI Zahar
I Zahar
AZAz Zain
Az Zain
ESE Sasmita
E Sasmita
MRM Restiwijaya
M Restiwijaya
MNMuhammad Nur
Muhammad Nur