5 August 2021 in Journal of Thrombosis and Haemostasis
1 April 2018 in Journal of Biomechanics
4 April 2018 in Journal of Biomechanical Engineering
Pelvic fractures are serious injuries resulting in high mortality and morbidity. The objective of this study is to develop and validate local pelvic anatomical, cross section-based injury risk metrics for a finite element (FE) model of the human body. Cross-sectional instrumentation was implemented in the pelvic region of the Global Human Body Models Consortium (GHBMC M50-O) 50th percentile detailed male FE model (v4.3). In total, 25 lateral impact FE simulations were performed using input data from cadaveric lateral impact tests performed by Bouquet et al. The experimental force-time data were scaled using five normalization techniques, which were evaluated using log rank, Wilcoxon rank sum, and correlation and analysis (CORA) testing. Survival analyses with Weibull distribution were performed on the experimental peak force (scaled and unscaled) and the simulation test data to generate injury risk curves (IRCs) for total pelvic injury. Additionally, IRCs were developed for regional injury using cross-sectional forces from the simulation results and injuries documented in the experimental autopsies. These regional IRCs were also evaluated using the receiver operator characteristic (ROC) curve analysis. Based on the results of all the evaluation methods, the equal stress equal velocity (ESEV) and ESEV using effective mass (ESEV-EM) scaling techniques performed best. The simulation IRC shows slight under prediction of injury in comparison to these scaled experimental data curves. However, this difference was determined not to be statistically significant. Additionally, the ROC curve analysis showed moderate predictive power for all regional IRCs.
19 January 2017 in Annals of Biomedical Engineering
23 November 2020 in Journal of Biomechanical Engineering
Injury due to underbody loading is increasingly relevant to the safety of the modern warfighter. To accurately evaluate injury risk in this loading modality, a biofidelic anthropomorphic test device (e.g., dummy) is required. Finite element model counterparts to the physical dummies are also useful tools in the evaluation of injury risk, but require validated constitutive material models used in the dummy. However, material model fitting can result in models that are over-fit: they match well with the data they were trained on, but do not extrapolate well to new loading scenarios. In this study, we used a hierarchical approach. Material models created from coupon-level tests were evaluated at the component level, and then verified using blinded component and whole body (WB) tests to establish a material model of the anthropomorphic test device (ATD) neck that was not over-fit. Additionally, a combined metric is introduced that incorporates the well-known correlation analysis (CORA) score with peak characteristics to holistically evaluate the material model performance. A Bergstrom Boyce material model fit to one loop of combined compression and tension experimental data performed the best within the training datasets. Its combined metric scores were 2.51 and 2.18 (max score of 3) in a constrained neck and head neck setup, respectively. In the blinded evaluation including flexed, extended, and WB simulations, similar combined scores were observed with 2.44, 2.26, and 2.60, respectively. The agreement between the combined scores in the training and validation dataset indicated that model was not over-fit and can be extrapolated into untested, but similar loading scenarios.
13 January 2026 in Annals of Biomedical Engineering
Sophisticated biofidelic finite element (FE) models of sideways falls are an emerging tool for predicting hip fracture risk. We adapted an existing experimental setup for in-silico trials by creating an automated workflow to build FE models of the experiment and characterizing it with respect to the effects of limited CT scan coverage. Limited CT scan coverage was simulated by shortening the femur (25–175mm distal to the greater trochanter), misaligning the femur up to 5 degrees, and using a morphed template pelvis. We compared impact force error ( E
BL
) of the FE results to the existing experimental results. We then characterized the limited CT scan coverage with respect to the impact force ( E
I
), femur force ( E
F
), and fragility ratios based on the impact force ( E
FRI
) and the femur force ( E
FRF
) by comparing results to a model without any of these scan-related errors introduced. In general, the baseline simulations agreed well with the experiments ( E
BL
: μ = − 0.007 kN, σ = 0.409 kN). When scan coverage errors were introduced, the errors were small ( E
I
: μ = 0.082kN, σ = 0.232kN; E
F
: μ = 0.063 kN, σ = 0.228 kN; E
FRI
: μ = − 0.00, σ = 0.058; E
FRF
: μ = − 0.012, σ = 0.074). The pelvis template used explained the most variance of the output measures ( E
I
R 2 = 0.876; E
F
R 2 = 0.880; E
FRI
R 2 = 0.901; E
FRF
R 2 = 0.884). These results indicate that this automated methodology is suitable for typical scan coverages encountered clinically, and future work should use this workflow to explore fragility fractures in larger clinical cohorts.