Injecting radio frequency (RF) white noise to the current driving of the laser can broaden the laser emission linewidth and efficiently suppress cavity-mode noise in off-axis integrated cavity output spectroscopy (OA-ICOS). The effect of the injected RF noise level on the cavity-mode noise and the deformation of the absorption line shape in off-axis integrated cavity output spectroscopy (OA-ICOS) with a distributed feedback laser (DFB) at 1.65 µm were investigated. We measured methane at different concentrations between 0.1 ppmv and 2 ppmv associated with a −20 dBm RF noise injection. A linear spectral response of the intensity of the cavity output spectra with the CH4 concentration was observed. A threefold improvement in the detection limit was achieved compared to unperturbed OA-ICOS. The response time of the improved OA-ICOS system is about 30 s and the minimum detectable concentration (MDC) of CH4 is 7.6 ppbv, which corresponds to a minimum detectable fractional absorption scaled to the path length of 7.3 × 10−10 cm−1. The noise equivalent absorption sensitivity of the system is 5.51 × 10−9 cm−1Hz-1/2.
The performance of an interband cascade laser based laser heterodyne radiometer (LHR) is demonstrated in ground-based solar occultation mode. High-resolution (0.0033 cm−1) transmission spectra near 3.53 μm were obtained for simultaneous atmospheric observations of H2O and CH4. Combined with the preprocessed measurement data (acquired at Hefei, China, on June 21th 2016), an optimal estimation method based retrieval algorithm is developed for data retrieval and error analysis. By considering the corrected atmospheric parameters, vertical profiles of H2O and CH4 are retrieved. Finally, the measured total column abundance and XCH4 were calculated to be 1.87 ± 0.02 ppm and 1.88 ± 0.02 ppm, respectively. The interband cascade laser-based laser heterodyne radiometer that is demonstrated in this manuscript has high potential for use in the development of compact, robust, and unattended LHR for spacecraft, airborne or ground-based atmospheric sensing.
In this Letter, a new method is proposed to further improve the detection sensitivity of the gas sensor based on off-axis integrated cavity spectroscopy (OA-ICOS) using a distributed feedback laser operating in the near-infrared at 1653 nm that relies on implementation of wavelength modulation and radio frequency (RF) white noise perturbation to diode laser current. More than sixfold improvement in detection limit is achieved for an RF noised wavelength-modulated OA-ICOS compared to the unperturbed conventional OA-ICOS approach.