Wang Guishi

Dr. Wang Guishi

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KLKun Liu
Kun Liu
LWLei Wang
Lei Wang
TTTu Tan
Tu Tan
WGWang Guishi
Wang Guishi
WZWeijun Zhang
Weijun Zhang
XGXiaoming Gao
Xiaoming Gao

1 December 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KLKun Liu
Kun Liu
YCYuan Cao
Yuan Cao
WGWang Guishi
Wang Guishi
WZWeijun Zhang
Weijun Zhang
WCWeidong Chen
Weidong Chen
XGXiaoming Gao
Xiaoming Gao

12 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GMGu Mingsi
Gu Mingsi
JCJiajin Chen
Jiajin Chen
YZYiping Zhang
Yiping Zhang
TTTu Tan
Tu Tan
WGWang Guishi
Wang Guishi
JMJiaoxu Mei
Jiaoxu Mei
We designed a tunable diode laser absorption spectroscopy (TDLAS) sensor for the online monitoring of CO2 and H2O concentrations. It comprised a small self-design multi-pass cell, home-made laser drive circuits, and a data acquisition circuit. The optical and electrical parts and the gas circuit were integrated into a portable carrying case (height = 134 mm, length = 388 mm, and width = 290 mm). A TDLAS drive module (size: 90 mm × 45 mm) was designed to realize the function of laser current and temperature control with a temperature control accuracy of ±1.4 mK and a current control accuracy of ±0.5 μA, and signal acquisition and demodulation. The weight and power consumption of the TDLAS system were only 5 kg and 10 W, respectively. Distributed feedback lasers (2004 nm and 1392 nm) were employed to target CO2 and H2O absorption lines, respectively. According to Allan analysis, the detection limits of CO2 and H2O were 0.13 ppm and 3.7 ppm at an average time of 18 s and 35 s, respectively. The system response time was approximately 10 s. Sensor performance was verified by measuring atmospheric CO2 and H2O concentrations for 240 h. Experimental results were compared with those obtained using a commercial instrument LI-7500, which uses non-dispersive infrared technology. Measurements of the developed gas analyzer were in good agreement with those of the commercial instrument, and its accuracy was comparable. Therefore, the TDLAS sensor has strong application prospects in atmospheric CO2 and H2O concentration detection and ecological soil flux monitoring.

16 November 2022 in Optics Express
Verified
Journal Article
Closed access
MGMingsi Gu
Mingsi Gu
JCJiajin Chen
Jiajin Chen
JMJiaoxu Mei
Jiaoxu Mei
TTTu Tan
Tu Tan
WGWang Guishi
Wang Guishi
XGXiaoming Gao
Xiaoming Gao
We report an open-path and anti-pollution multi-pass cell based tunable diode laser absorption spectroscopy (TDLAS) sensor, which was designed for online measurement of atmospheric H2O and CO2 fluxes. It is mainly composed of two plano-convex mirrors coated on a convex surface, which makes it different from traditional multi-pass cells. This design does not allow a direct contact between the coating layer of the lens and air, thereby realizing the anti-pollution effect of the coating layer. Two DFB lasers operating at 1392 nm and 2004 nm were employed to target H2O and CO2 absorption lines, respectively. Allan analysis of variance indicated that detection limits of H2O and CO2 were 5.98 ppm and 0.68 ppm, respectively, at an average time of 0.1 s. The sensor performance was demonstrated by measuring CO2 and H2O flux emissions at Jiangdu Agricultural Monitoring Station in Jiangsu Province. The results were compared with those obtained using the commercial instrument LI-7500, which is based on non-dispersive infrared technology. The developed gas analysis instrument exhibited good consistency with commercial instruments, and its accuracy was comparable; thus, it has strong application prospects for flux measurements in any ecosystem.

19 March 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
JWJ. Wang
J. Wang
WGWang Guishi
Wang Guishi
TTTu Tan
Tu Tan
GZG. Zhu
G. Zhu
CSC. Sun
C. Sun
XGX. Gao
X. Gao
The performance of an interband cascade laser based laser heterodyne radiometer (LHR) is demonstrated in ground-based solar occultation mode. High-resolution (0.0033 cm−1) transmission spectra near 3.53 μm were obtained for simultaneous atmospheric observations of H2O and CH4. Combined with the preprocessed measurement data (acquired at Hefei, China, on June 21th 2016), an optimal estimation method based retrieval algorithm is developed for data retrieval and error analysis. By considering the corrected atmospheric parameters, vertical profiles of H2O and CH4 are retrieved. Finally, the measured total column abundance and XCH4 were calculated to be 1.87 ± 0.02 ppm and 1.88 ± 0.02 ppm, respectively. The interband cascade laser-based laser heterodyne radiometer that is demonstrated in this manuscript has high potential for use in the development of compact, robust, and unattended LHR for spacecraft, airborne or ground-based atmospheric sensing.

24 March 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
HYHongming Yi
Hongming Yi
TWTao Wu
Tao Wu
WGWang Guishi
Wang Guishi
WZWeixiong Zhao
Weixiong Zhao
EFEric Fertein
Eric Fertein
Weidong ChenWeidong Chen
Weidong Chen
We overview our recent progress in the developments and applications of light emitting diode-based incoherent broadband cavity enhanced absorption spectroscopy (LED-IBBCEAS) techniques for real-time optical sensing chemically reactive atmospheric species (HONO, NO3, NO2) in intensive campaigns and in atmospheric simulation chamber. New application of optical monitoring of NO3 concentration-time profile for study of the NO3-initiated oxidation process of isoprene in a smog chamber is reported.