Di Zhan

Di Zhan

Auto-generated profile, based on publicly available information

Di Zhan

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YYYifan Yan
Yifan Yan
SZShaowen Zhang
Shaowen Zhang
ZLZehua Liu
Zehua Liu
DZDi Zhan
Di Zhan
ZLZiao Liu
Ziao Liu
Jixi LuJixi Lu
Jixi Lu
Elliptically polarized atomic magnetometers (AMs) offer high sensitivity and compactness by using a single laser beam to polarize atoms and detect optical rotation angles. However, their sensitivity advantage over optical absorption-based AMs has not been sufficiently demonstrated. This is because the optical parameters significantly affect the pumping and probing processes, leading to parameter coupling when both processes are optimized simultaneously. Such coupling presents a considerable challenge for achieving simultaneous parameter optimization, ultimately limiting the achievable sensitivity. In this study, we developed a modified input-output model for a magnetometer, based on which an optical parameter decoupling and optimization method is proposed. Our method enables us to obtain the optimal optical parameters simultaneously, including the ellipticity, intensity, and frequency of light. Consequently, a sensitivity of 6 fT/Hz 1/2 was achieved using a 4 × 4 × 4 mm 3 87 Rb vapor cell (effective volume of 0.027 cm 3 ). This work offers an efficient strategy to achieve higher sensitivity using single-beam miniaturized AMs, contributing significantly to promote biomagnetism research.

16 February 2022 in The Journal of Arts Management, Law, and Society
Verified
Journal Article
Closed access
HDHuimin Deng
Huimin Deng
DZDi Zhan
Di Zhan
Abstract Danmu is the Chinese pinyin of 弹幕, which is often used to describe the interactive, on-screen commenting system featured by both sub-cultural bullet-screen platforms and dominant video-sharing platforms. While the transformation of the power relationship between the public and the official and between viewer and author has received considerable scholarly attention, less attention has been paid to how the danmu system has affected the textuality of contemporary online audiovisual texts. Based on the Bakhtinian carnival, this paper explores the textual structure and signifying mechanism of danmu. It argues that danmu has dual textual identity, the paratext of online videos and the textual component of bullet-screen videos respectively. Danmu allows viewers to not only make comments on online videos but also reconstruct them. Such interactive construction of online audiovisual texts represents the rise of mass writing.

17 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DZDi Zhan
Di Zhan
YWYaoguo Wang
Yaoguo Wang
ZLZiao Liu
Ziao Liu
YYYifan Yan
Yifan Yan
YWYuesong Wu
Yuesong Wu
Jixi LuJixi Lu
Jixi Lu
Compared to single axis measurement, multi-axis spin-exchange relaxation-free (SERF) atomic magnetometer has shown its superiorities in bio-magnetic measurement recently. However, in multi-axis measurement, cross-axis coupling error can introduce undesired output in the response signals, which varies with frequency and will have an adverse effect on measurement accuracy. To effectively suppress this error, we propose a full-frequency-range dual-axis cross-axis decoupling method based on amplitude-phase characteristics for dual-beam magnetometer. We analyze and measure the cross-axis coupling effect under different residual magnetic fields along the z-axis, and demonstrated that the residual magnetic field along the zaxis has great impact on the cross-axis coupling. Although the cross-axis coupling can be minimized by adjusting the residual magnetic field along the z-axis to zero, the cross-axis coupling still remains. Therefore, we establish the input-output equation in matrix form and derive the complex transform matrix based on amplitude-phase characteristics. Then we utilize the corresponding solving matrix to calculate the decoupling measurement results from the response signals under different cases of magnetic fields. Our method can realize a dual-axis complete decoupling measurement within full-frequency-range and provides a comprehensive description of the magnetic fields to be measured, including amplitude and phase information. The validity and effectiveness of our decoupling method is verified and it is demonstrated that our method can markedly enhance the measurement accuracy. We can realize the measurement error of the magnetic field phase difference lower than 1°, the relative measurement error of the magnetic field amplitude along the x-axis lower than 0.23% and that along the y-axis lower than 0.02%. Moreover, this method can be extended to any linear multi-axis measurement system.

11 September 2026 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
YWYaoguo Wang
Yaoguo Wang
DZDi Zhan
Di Zhan
JLJixi Lu
Jixi Lu
PXPing Xu
Ping Xu
ZWZhuo Wang
Zhuo Wang
JFJiancheng Fang
Jiancheng Fang
Near-zero-field magnetometers, particularly the spin-exchange relaxation-free (SERF) magnetometer, despite their exceptional sensitivity, face a fundamental limitation: their accuracy is inherently tied to the precision of precalibrated magnetic coils, creating a circular dependency in calibration. To break this loop, we establish a comprehensive analytical framework to describe the full-sequence free-induction-decay (FID) trajectories of atomic ensembles in the near-zero magnetic field regime. By explicitly incorporating the dynamic evolution of the polarization-dependent slowing-down factor $q(P)$, our model provides a rigorous description of spin precession in ultraweak field environments, enabling the extraction of absolute field components without relying on external coil-based references. The mathematical integrity of the model is confirmed by excellent agreement with direct numerical simulations of the Bloch equations. We demonstrate that a single FID waveform can simultaneously resolve six independent physical parameters through a multiparameter nonlinear estimation process. Experimental results validate that the reconstructed magnetic fields exhibit high fidelity, with a coefficient of determination of approximately 0.99. Under current experimental conditions, this approach achieves a practical reconstruction uncertainty of 0.1 nT for the absolute magnetic field and 5 and $1\text{ }{\mathrm{s}}^{\ensuremath{-}1}$ for pumping and relaxation rates, respectively. This work redefines the SERF magnetometer as a calibration-free magnetometer, providing a robust foundation for autonomous quantum sensing in remote or inaccessible environments.

5 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYaoguo Wang
Yaoguo Wang
DZDi Zhan
Di Zhan
XFXiujie Fang
Xiujie Fang
YZYaqi Zhang
Yaqi Zhang
FWFaming Wang
Faming Wang
DMDanyue Ma
Danyue Ma
Conventional methods for enhancing the response of SERF magnetometers primarily focus on optimization of the cell working state but remain constrained by the limited equilibrium polarization. To overcome this limitation, we proposed a response-enhanced over-polarization measurement method for SERF magnetometer based on pump beam modulation, which allows the polarization and measurement processes to be independent. We established the theoretical model of the transverse polarization during the transient response after the pump beam is altered off. Then we verified the validity of our method under different modulation frequencies and duty cycles, and proposed the parameter selection criteria to meet the acquirements of our over-polarization measurement mode. Compared to the traditional DC-mode, numerical simulation and experiment have both demonstrated that the response can be enhanced by 47% and 43%, respectively, which is consistent with our theoretical analysis. Moreover, this method inherently mitigates the light-shift effect and facilitates high polarization uniformity across the vapor cell. These findings, supported by comprehensive sensitivity analysis and robustness evaluation, demonstrate the method's potential for practical applications in high-sensitivity magnetometry, such as biomagnetic imaging and anomaly detection.

18 March 2026 in Measurement
Verified
Journal Article
Closed access
DZDi Zhan
Di Zhan
YWYaoguo Wang
Yaoguo Wang
ZLZiao Liu
Ziao Liu
YYYifan Yan
Yifan Yan
ZHZhaohui Hu
Zhaohui Hu
Jixi LuJixi Lu
Jixi Lu