Tomasz Chodukowski

Tomasz Chodukowski

Auto-generated profile, based on publicly available information

Tomasz Chodukowski

Institute of Plasma Physics and Laser Microfusion

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2009 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
PKPavel Kubes
Pavel Kubes
MPMarian Paduch
Marian Paduch
TPTadeusz Pisarczyk
Tadeusz Pisarczyk
MSMarek Scholz
Marek Scholz
TCTomasz Chodukowski
Tomasz Chodukowski
EZEwa Zielinska
Ewa Zielinska
A plasma column generated in the PF-1000 device working in deuterium gas at a current level of 1 MA was investigated with interferometric diagnostics and scintillation detectors. The beam of diagnostic laser of 527-nm wavelength was optically split into 16 beams with a time delay in the range from 0 to 220 ns. This diagnostic tool makes possible the imaging of the evolution of pinch geometry, the axial and radial distributions of plasma density in the column at the stagnation phase, and their comparison with the evolution of X-ray and neutron production. The evolution of dense structure is described with respect to its importance for fusion processes.

1 February 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MKMichal Krupka
Michal Krupka
SSSushil Kumar Singh
Sushil Kumar Singh
TPT. Pisarczyk
T. Pisarczyk
JDJ. Dostal
J. Dostal
MKM. Kalal
M. Kalal
Libor JuhaLibor Juha
Libor Juha
This paper describes design, development, and implementation of a multi-channel magnetic electron spectrometer for the application in laser–plasma interaction experiments carried out at the Prague Asterix Laser System. Modular design of the spectrometer allows the setup in variable configurations to evaluate the angular distribution of hot electron emission. The angular array configuration of the electron spectrometers consists of 16 channels mounted around the target. The modules incorporate a plastic electron collimator designed to suppress the secondary radiation by absorbing the wide angle scattered electrons and photons inside the collimator. The compact model of the spectrometer measures electron energies in the range from 50 keV to 1.5MeV using ferrite magnets and from 250 keV to 5MeV using stronger neodymium magnets. An extended model of the spectrometer increases the measured energy range up to 21MeV or 35MeV using ferrite or neodymium magnets, respectively. Position to energy calibration was obtained using the particle tracking simulations. The experimental results show the measured angularly resolved electron energy distribution functions from interaction with solid targets. The angular distribution of hot electron temperature, the total flux, and the maximum electron energy show a directional dependence. The measured values of these quantities increase toward the target normal. For a copper target, the average amount of measured electron flux is 1.36 × 1011, which corresponds to the total charge of about 21 nC.

11 June 2024 in Physical Review Research
Verified
Journal Article
Open access
PDF file
VOV. Ospina-Bohórquez
V. Ospina-Bohórquez
CSCarlos Salgado-López
Carlos Salgado-López
MEMichael Ehret
Michael Ehret
SMS. Malko
S. Malko
MSM. Salvadori
M. Salvadori
JSJ. J. Santos
J. J. Santos
Ion acceleration from gaseous targets driven by relativistic-intensity lasers was demonstrated as early as the late 1990s, yet most of the experiments conducted to date have involved picosecond-duration, Nd:glass lasers operating at low repetition rate. Here, we present measurements on the interaction of ultraintense (≈1020Wcm−2, 1 PW), ultrashort (≈70fs) Ti:Sa laser pulses with near-critical (≈1020cm−3) helium gas jets, a debris-free targetry with the potential for future compatibility with high (≈1 Hz) repetition rate operation. We provide evidence of α particles being forward accelerated up to ≈2.7−MeV energy with a total flux of ≈1011sr−1 as integrated over >0.1−MeV energies and detected within a 0.5−mrad solid angle. We also report on on-axis emission of relativistic electrons with an exponentially decaying spectrum characterized by a ≈10−MeV slope, i.e., five times larger than the standard ponderomotive scaling. The total charge of these electrons with energy above 2 MeV is estimated to be of ≈1nC, corresponding to ≈0.1% of the laser drive energy. In addition, we observe the formation of a plasma channel, extending longitudinally across the gas density maximum and expanding radially with time. These results are well captured by large-scale particle-in-cell simulations, which reveal that the detected fast ions most likely originate from reflection off the rapidly expanding channel walls. The latter process is predicted to yield ion energies in the MeV range, which compare well with the measurements. Finally, direct laser acceleration is shown to be the dominant mechanism behind the observed electron energization.

1 November 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
AZA. Zaraś-Szydłowska
A. Zaraś-Szydłowska
TPT. Pisarczyk
T. Pisarczyk
TCT. Chodukowski
T. Chodukowski
ZRZ. Rusiniak
Z. Rusiniak
RDR. Dudzak
R. Dudzak
PPP. Pisarczyk
P. Pisarczyk
Generation of spontaneous magnetic fields (SMFs) is one of the most interesting phenomena accompanying an intense laser–matter interaction. One method of credible SMFs measurements is based on the magneto-optical Faraday effect, which requires simultaneous measurements of an angle of polarization plane rotation of a probe wave and plasma electron density. In classical polaro-interferometry, these values are provided independently by polarimetric and interferometric images. Complex interferometry is an innovative approach in SMF measurement, obtaining information on SMF directly from a phase–amplitude analysis of an image called a complex interferogram. Although the theoretical basis of complex interferometry has been well known for many years, this approach has not been effectively employed in laser plasma research until recently; this approach has been successfully implemented in SMF measurement at the Prague Asterix Laser System (PALS). In this paper, proprietary construction solutions of polaro-interferometers are presented; they allow us to register high-quality complex interferograms in practical experiments, which undergo quantitative analysis (with an original software) to obtain information on the electron density and SMFs distributions in an examined plasma. The theoretical foundations of polaro-interferometric measurement, in particular, complex-interferometry, are presented. The main part of the paper details the methodology of the amplitude–phase analysis of complex interferograms. This includes software testing and examples of the electron density and SMF distribution of a laser ablative plasma generated by irradiating Cu thick planar targets with an iodine PALS laser at an intensity above about 1016 W/cm2.

1 March 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
CVC. Vlachos
C. Vlachos
VOV. Ospina-Bohórquez
V. Ospina-Bohórquez
PBP. W. Bradford
P. W. Bradford
GPGabriel Perez-Callejo
Gabriel Perez-Callejo
MEMichael Ehret
Michael Ehret
JSJ. J. Santos
J. J. Santos
We present measurements of magnetic fields generated in laser-driven coil targets irradiated by laser pulses of nanosecond duration, 1.053 μm wavelength, 500 J energy, and ∼1015 W/cm2 intensity, at the LULI2000 facility. Using two perpendicular probing axes, proton deflectometry is used to characterize the coil current and static charge at different times. Results reveal various deflection features that can be unambiguously linked to a looping quasi-steady current of well-understood polarity or to a static charging of the coil surface. Measured currents are broadly consistent with predictions from a laser-driven diode-current source and lumped circuit model, supporting the quasi-steady assessment of the discharges. Peak magnetic fields of ∼50 T at the center of 500-μm-diameter coils, obtained at the moderate laser intensity, open up the use of such laser-driven coil targets at facilities worldwide to study numerous phenomena in magnetized high-energy-density plasmas, and its potential applications.

1 October 2021 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
IKIu. Kochetkov
Iu. Kochetkov
TPT. Pisarczyk
T. Pisarczyk
MKM. Kalal
M. Kalal
TCT. Chodukowski
T. Chodukowski
AZA. Zaraś-Szydłowska
A. Zaraś-Szydłowska
PKPhilipp Korneev
Philipp Korneev
Expanding laser plasmas, produced by high energy laser radiation, possess both high thermal and magnetic field energy densities. Characterization of such plasma is challenging but may provide essential information needed for understanding its physical behavior. Among the standard experimental techniques used for plasma diagnostics, conventional interferometry is one of the most convenient, informative, and accurate. Attempts to extract more information from each laser shot on large facilities have led to development of complex interferometry, which allows us to reconstruct both plasma electron density and magnetic field distributions from a single data object. However, such a benefit requires more accurate processing, critically important in some situations. This work focuses on quasi-axisymmetric interaction geometry. Starting from basic principles, we present a general analysis, consider main error sources, and obtain plasma density and magnetic field distributions with their derived error bars. A regularization procedure, significantly decreasing an error near the plasma symmetry axis, is proposed and analyzed in detail. With use of synthetic datasets, the presented analysis is generally universal for quasi-axisymmetric plasmas.