5 July 2016 in Nuclear Fusion
This paper describes a new method to derive, from soft x-ray (SXR) tomography, robust estimates of the core displacement, growth rate and frequency of a 1/1 sawtooth crash precursor. The method is valid for very peaked SXR profiles and is robust against both the inversion algorithm and the presence of tungsten in a rotating plasma. Three typical ASDEX Upgrade crashes are then analysed. In all cases a postcursor is observed, suggesting incomplete reconnection. Despite different dynamics, in all three cases the growth rate of the core displacement shows similar features. First, it is not constant, supporting the idea of non-linear growth. Second, it can be divided into clearly identified phases with quasi-constant growth rates, suggesting sudden change of growth regime rather than smooth transitions. Third, its evolution is non-monotonic, with phases of accelerated growth followed by damped phases. This damping is interpreted for two cases respectively as an effect of fast ions and of mode coupling, based on the result of a MHD simulation. The mode frequency is observed in all cases to be closely related to the plasma bulk rotation profile, with little or no visible effect of the electron diamagnetic drift frequency. The onset criterion could not be clearly identified and it is shown that the role of the pressure gradient is not as expected from a naive extrapolation of the linear stability theory.
1 October 2024 in Review of Scientific Instruments
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
1 August 2024 in Review of Scientific Instruments
The SPARC tokamak will be equipped with a hard X-ray (HXR) monitor system capable of measuring the bremsstrahlung emission from runaway electrons with photon energies in excess of about 100 keV. This diagnostic will detect the formation of runaway electron beams during plasma start-up and inform the plasma control system to terminate the discharge early to protect the machine. In this work, we present a 0D estimate of the HXR emission in SPARC during plasma start-up. Then we discuss the characterization of a prototype of the HXR monitor. The detector mounts a 1 × 1-in.2 LaBr3 inorganic scintillator coupled with a photomultiplier tube and has been tested with γ-ray sources to find its dynamic range. Finally, two possible modes of operation for spectroscopic and current mode measurements on SPARC are proposed.
1 September 2024 in Review of Scientific Instruments
An overview is given of SPARC’s three main x-ray diagnostics, with a focus on the functions they fulfill with respect to tokamak operation. The first is an in-vessel soft x-ray tomography diagnostic, aimed at providing early campaign information on plasma position, MHD activity, and impurity content. The second is an ex-vessel set of hard x-ray scintillators aimed at detecting the presence of runaway electrons, in particular during plasma startup phases. The third is a set of x-ray Bragg spectrometers, located outside of the tokamak hall, aimed at informing on the ion temperature as an indirect constraint to reduce uncertainties on the fusion power, on providing plasma rotation velocity estimates, and on observing impurity emission. Finally, more technical details are given on the beamlines at the end of which the spectrometers are located. It explains how their design allows us to ensure tritium containment and limit neutron radiation while providing a straight view into the plasma that can also be used for testing new innovative sensors.
1 September 2024 in Review of Scientific Instruments
The in-vessel silicon diode arrays that are used for soft x-ray detection in many tokamaks are sensitive to neutron damage, making them unsuitable for burning plasma devices such as SPARC. In such a device, the silicon diodes would need to be placed far from the plasma—limiting their field of view—or an alternative detector could be used. Here, we present the design of a camera containing an array of chemical vapor deposition single-crystal diamonds, which will be placed in the upper and lower port plugs of the SPARC tokamak with a large enough view of the poloidal cross section to enable tomographic inversion. The camera design presented here is optimized to provide a wide field of view of the poloidal cross section. Simulated plasma conditions are used to estimate the x-ray signal that this detector array will receive and to fine-tune the camera placement within the tokamak.
1 August 2024 in Review of Scientific Instruments
SPARC will be outfitted with three systems of x-ray crystal spectrometer arrays. Two of these are designed using cylindrically bent crystals to achieve high spectral-resolution for ion temperature and toroidal velocity measurements via imaging He-like Kr and Ne-like Xe. The last acts as a spectral survey system to monitor Ne-like W and nearby H- and He-like emission from Cr, Fe, Co, Ni, and Cu. Line radiation intensities are calculated using the Flexible Atomic Code for atomic data and ColRadPy for collisional-radiative modeling, then convoluted with a Voigt line shape. Free–free, free-bound, and two-photon continuum radiation is also included. The ToFu code is used to perform volume-of-sight integration to produce synthetic detector images. In addition, presented is cross-validation performed using the XICSRT Monte Carlo ray-tracing code. Ion temperature and toroidal velocity profiles are reconstructed using ToFu via tomographic inversion.