Myriam Koch

Myriam Koch

Auto-generated profile, based on publicly available information

Myriam Koch

High Voltage Laboratories, Technical University of Darmstadt, Darmstadt, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
YSYvonne Späck-Leigsnering
Yvonne Späck-Leigsnering
GRGreta Ruppert
Greta Ruppert
EGErion Gjonaj
Erion Gjonaj
Herbert De GersemHerbert De Gersem
Herbert De Gersem
MKMyriam Koch
Myriam Koch
Extruded high-voltage direct current cable systems transmit electric power over long distances. Numerical field simulation can provide access to the internal electrothermal behavior of cable joints, which interconnect cable sections. However, coupled nonlinear electrothermal field simulations are still a challenge. In this work, a robust numerical solution approach is implemented and validated. This approach allows for efficient parameter studies of resistively graded high-voltage direct current cable joint designs. It is assessed how the dielectric stress distribution between the conductor connection and the grounded cable sheath is influenced by nonlinear field and temperature dependent electric conductivity of the field grading material. Optimal field grading material parameters, which fulfill the field grading and power loss requirements, are suggested based on the simulation studies.

1 October 2014
Verified
Conference Paper
Open access
MKM. Koch
M. Koch
MBM. Bujotzek
M. Bujotzek
CFC. M. Franck
C. M. Franck
First generation gas insulated switchgears were constructed with large safety margin. Today's trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of the exact inception level of partial discharges due to those imperfections is of interest. The goal of the present contribution is to measure the discharge inception voltage in SF 6 in a homogeneous field configuration with a small protrusion with unprecedented high accuracy. With a short pulse X-ray source first electrons are provided within the critical volume. The experimental results show for a 0.2 MPa SF 6 insulation a threshold voltage of roughly 80 kV for positive and negative polarity at the protrusion, respectively. These inception voltages match the calculated theoretical inception level. The proposed method allows determining the inception voltage in a more efficient way as the experiment time is reduced.

16 September 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
MMMaximilian Millisterfer
Maximilian Millisterfer
DVDominik Viebke
Dominik Viebke
MKMyriam Koch
Myriam Koch
Future generations of gas-insulated metalenclosed switchgear should be operated with an environmentally friendly alternative insulating gas instead of sulfur hexafluoride. A promising alternative is pressurized synthetic air. To reliably design these systems, it is essential to predict the breakdown probability. For this purpose, the breakdown probability of a weakly nonuniform, polished hemisphere-plate electrode arrangement is evaluated through voltage rise tests. These tests are conducted under negative and positive lightning impulse voltage stress at pressures up to 1.0 MPa and room temperature. Alongside the experiments, a simulation model is developed using the volume-time law to predict the breakdown probability based on the start electron provision. The simulation parameters are empirically adjusted to ensure a high degree of agreement between the measured and calculated breakdown probabilities. This adaptation enables the determination of pressure- and polarity-dependent effects on the field stress enhancement factor, the minimum macroscopic background field strength, and the negative ion density.

14 May 2025
Verified
Conference Paper
Open access
PDF file
MRMaren Greta Greta Ruppert
Maren Greta Greta Ruppert
Herbert De GersemHerbert De Gersem
Herbert De Gersem
YSYvonne Späck-Leigsnering
Yvonne Späck-Leigsnering
MKMyriam Koch
Myriam Koch
An adjoint sensitivity analysis of a nonlinear transient finite-element model allows to determine the sensitivities of the key performance indicators of a cable joint with respect to the parameters of an embedded field-grading material. The example considers a high-voltage DC cable joint submitted to an overvoltage event.

1 January 2026 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
MNManuel Nierenberg
Manuel Nierenberg
MKMyriam Koch
Myriam Koch
MKMichael Kurrat
Michael Kurrat

1 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MKMichael Kempf
Michael Kempf
MKMyriam Koch
Myriam Koch