To meet the radiosonde requirement of high sensitivity and linearity, this study designs and implements a monolithically integrated array-type piezoresistive intelligent pressure sensor system which is made up of two groups of four pressure sensors with the pressure range of 0–50 kPa and 0–100 kPa respectively. First, theoretical models and ANSYS (version 14.5, Canonsburg, PA, USA) finite element method (FEM) are adopted to optimize the parameters of array sensor structure. Combing with FEM stress distribution results, the size and material characteristics of the array-type sensor are determined according to the analysis of the sensitivity and the ratio of signal to noise (SNR). Based on the optimized parameters, the manufacture and packaging of array-type sensor chips are then realized by using the standard complementary metal-oxide-semiconductor (CMOS) and microelectromechanical system (MEMS) process. Furthermore, an intelligent acquisition and processing system for pressure and temperature signals is achieved. The S3C2440A microprocessor (Samsung, Seoul, Korea) is regarded as the core part which can be applied to collect and process data. In particular, digital signal storage, display and transmission are realized by the application of a graphical user interface (GUI) written in QT/E. Besides, for the sake of compensating the temperature drift and nonlinear error, the data fusion technique is proposed based on a wavelet neural network improved by genetic algorithm (GA-WNN) for average measuring signal. The GA-WNN model is implemented in hardware by using a S3C2440A microprocessor. Finally, the results of calibration and test experiments achieved with the temperature ranges from −20 to 20 °C show that: (1) the nonlinear error and the sensitivity of the array-type pressure sensor are 8330 × 10−4 and 0.052 mV/V/kPa in the range of 0–50 kPa, respectively; (2) the nonlinear error and the sensitivity are 8129 × 10−4 and 0.020 mV/V/kPa in the range of 50–100 kPa, respectively; (3) the overall error of the intelligent pressure sensor system is maintained at ±0.252% within the hybrid composite range (0–100 kPa). The involved results indicate that the developed array-type composite pressure sensor has good performance, which can provide a useful reference for the development of multi-range MEMS piezoresistive pressure sensor.
For the health monitoring of the offshore drilling platform in the salt-fog environment, three nonmetallic materials, i.e., silica, FR-4 epoxy board and sheet molding compound (SMC), with the good anti-corrosion ability were chosen as the packaging materials for the fiber Bragg grating (FBG) strain sensors. By selecting a highly sensitive structure of the fiber Bragg grating strain sensor, the performances of the sensors with three materials were investigated both numerically and experimentally. The strain sensitivities were 3.76 pm/μɛ, 3.02 pm/μɛ and 3.03 pm/μɛ, respectively. The linearity was better than 0.998. It provides useful information for developing sensors for the marine engineering.
15 September 2015 in IEEE Photonics Technology Letters
A wavelength-interrogation fiber Fabry-Perot refractive index (RI) sensor based on a sealed in-fiber ellipsoidal cavity is presented. There are two physical cavities in the sensor head: 1) the air cavity and 2) the silica cavity. The result of simulation shows there is only one trough in 1510-1590 nm, the RI can be measured by tracking the trough wavelength shift, and there is no turning point in RI response characteristic between 1 and 2 RIU. The sensitivity and linear range of the RI measurement can be controlled by changing the silica cavity's length and the sensor end's roughness. Experiment results match well with the theoretical analysis within the measurement range. High reliability, without turning point and real-time demodulation make it appropriate for practical application.
We present a highly sensitive refractive index (RI) sensor based on an ultra-compact in-fiber Mach-Zehnder interferometer (MZI) with a droplet-shape air-cavity. The droplet-shape air-cavity is fabricated by fusion splicing and single-side fused tapering. The fabricated MZI is with a very short interference arm of ∼330µm and the taper waist diameter of ∼40µm. The interference happens between the silica-cladding mode and the air-core mode. The trough wavelength of the interference with specific order in the transmission spectrum shifts with the change of surrounding refractive index. Experimental results show that this sensor offers high sensitivity (up to 2803.6nm/RIU at RI∼1.42) for RI measurement in the range of 1.3164-1.4270, which match well with the theoretical analysis. High RI sensitivity, high-spatial resolution, temperature insensitivity, easy fabrication and low-cost make it a competitive RI sensor in the biochemical and physical sensing fields.
This paper proposes a no-core-single-mode-no-core Mach–Zehnder fiber sensor. In this sensor, two no-core fibers serve as input and output couplers, and the middle single-mode fiber serves as a sensing arm. Using finite element simulation and theoretical analysis, the optimal length of the couplers and the sensing arm are determined. High-order modes excited by no-core optical fiber propagate through the cladding of the single-mode fiber, which is affected by the ambient temperature and applied force. The trough of different interference orders of the transmission spectrum is selected as a research object to realize the measurement of curvature and temperature, strain and temperature with the sensing matrix.