Tao Xu

Tao Xu

Auto-generated profile, based on publicly available information

Tao Xu

University of Science and Technology of China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2020 in IEEE Access
Verified
Journal Article
Open access
YZYong Zhang
Yong Zhang
TXTao Xu
Tao Xu
JHJinsheng Hu
Jinsheng Hu
ZHZhen Huang
Zhen Huang
Qiaosheng PanQiaosheng Pan
Qiaosheng Pan
A resonant-type piezoelectric screw motor for one degree of freedom (1-DOF) positioning platform is proposed, fabricated, and investigated in this article. The motor comprises a driver and a screw rod. The driver is composed of four transducers, a nut seat, and a flange nut. The flange nut is bolted connected on the nut seat, and the four piezoelectric transducers are connected with the nut seat by right-angle flexible hinges. Each piezoelectric transducer comprises two piezoelectric stacks and one displacement amplifier. Driven by the four piezoelectric transducers, elliptical vibration is generated by the driver, which is used to actuate the screw rod to realize the linear movement. The driver is analyzed using the finite element analysis software ANSYS. The proposed motor and positioning platform prototype are manufactured, assembled, and tested. The performance of the developed piezoelectric screw motor shows its applicability and effectiveness for the 1-DOF positioning platform with a large force. Experiments demonstrate that the maximum velocity of this motor is 10.53 mm/s without mechanical load and the maximum output force of the platform can reach 17.19 N when the excitation voltage is 230 Vp-p at 365 Hz.

27 March 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
TXTao Xu
Tao Xu
ZWZiqi Wang
Ziqi Wang
ZJZhiwei Jia
Zhiwei Jia
JCJian Chen
Jian Chen
ZFZhiHua Feng
ZhiHua Feng

2 March 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
SZShuyu Zhu
Shuyu Zhu
RLRongjie Li
Rongjie Li
TXTao Xu
Tao Xu
ZCZehui Chen
Zehui Chen
志冯志华 冯
志华 冯

29 November 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
SZShuyu Zhu
Shuyu Zhu
GCGuangzheng Chen
Guangzheng Chen
TXTao Xu
Tao Xu
JYJing Yin
Jing Yin
志冯志华 冯
志华 冯
This study introduces a novel method to increase the stability of the balance point in precision differential eddy current sensor (ECS) displacement sensors, which is crucial for achieving optimal performance and improving the interchangeability of sensor probes. The temperature drift coefficient at the electrical balance point (BTC), a common issue affecting the accuracy and reliability of measurements, is addressed through our approach. The BTC can be accurately adjusted by fine-tuning the length of the aluminum target, which aligns the zero-temperature drift position with the electrical balance position, thereby achieving a perfect balance point. The experimental results demonstrate that the proposed method significantly reduces the temperature drift near the balance point of the differential ECS. The BTC was effectively reduced from −7.21 nm/°C to 0.22 nm/°C. This substantial reduction in the BTC enhances the stability of the sensor, facilitating more reliable measurements in high-precision applications.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShuyu Zhu
Shuyu Zhu
RLRongjie Li
Rongjie Li
TXTao Xu
Tao Xu
ZFZilong Feng
Zilong Feng
LYLizhuang Yan
Lizhuang Yan
志冯志华 冯
志华 冯
This study proposes a novel differential eddy current inductive displacement sensor (ECIS) that achieves synchronous three-axis (XYZ) displacement measurement, overcoming the limitations of traditional single-axis detection. The sensor incorporates a spiral excitation coil, an aluminum target, and differential receiving coils bonded to the target surface. A hybrid-domain optimization framework combining theoretical modeling and finite element analysis (FEA) was developed to address the challenges of multiphysics coupling in proximity to conductive targets. The coil geometry was systematically optimized through numerical calculations to maximize sensitivity while suppressing cross-axis interference. Experimental validation demonstrated a displacement range of ±1,500 μm in the x- and y-axes and ±130 μm in the z-axis, achieving quasistatic resolutions of 10 nm, 13 nm, and 0.45 nm, respectively. The cross-sensitivity between axes was maintained below ±0.5%. The sensor's thermal stability was enhanced through Zerodur® glass probe structures and differential topology, yielding a temperature drift coefficient of 162 ppm/°C. These results validate the proposed optimization methodology and highlight the sensor's potential for ultraprecision metrology.

1 July 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GCGuangzheng Chen
Guangzheng Chen
KFKai Fan
Kai Fan
RNRunda Niu
Runda Niu
SZShuyu Zhu
Shuyu Zhu
TXTao Xu
Tao Xu
志冯志华 冯
志华 冯
This paper proposes a two-dimensional calibration method for resolving the nano-positioner pedestal micro-deformation crosstalk errors during the auction process. This refinement aims to enhance the nano-positioner’s accuracy and reduce coupling crosstalk errors. The reaction force exerted by the piezoelectric actuator can cause micro-deformation in the nano-positioner sensor pedestal, causing substantial errors in uncalibrated closed-loop control. This phenomenon has been previously overlooked. According to the two-degree of freedom parallel-symmetric decoupled nano-positioner deformation characteristics, a two-dimensional calibration matrix is proposed to suppress the crosstalk between two axes caused by the micro-deformation of the sensor pedestal. Experimental results show that the calibrated closed-loop system reduces X-axis and Y-axis coupling crosstalk errors to 1/67th and 1/18th of the uncalibrated closed-loop system, respectively, concurrently enhancing the positioning accuracy to 11.8 and 17 times that of the uncalibrated closed-loop system. The calibrated closed-loop feedback control method proposed in this paper proves effective for all compact nano-positioners with pedestal deformation issues. This research provides a crucial reference for the design of nano-positioners, offering insights into enhancing their accuracy and mitigating crosstalk issues.