4 March 2021 in Ear & Hearing
JLJeroen W. M. van der Laak
Jeroen W. M. van der Laak
+3
The global digital transformation enables computational audiology for advanced clinical applications that can reduce the global burden of hearing loss. In this article, we describe emerging hearing-related artificial intelligence applications and argue for their potential to improve access, precision, and efficiency of hearing health care services. Also, we raise awareness of risks that must be addressed to enable a safe digital transformation in audiology. We envision a future where computational audiology is implemented via interoperable systems using shared data and where health care providers adopt expanded roles within a network of distributed expertise. This effort should take place in a health care system where privacy, responsibility of each stakeholder, and patients’ safety and autonomy are all guarded by design.
2 February 2022 in Journal of Medical Internet Research
Background: Hearing loss affects 1 in 5 people worldwide and is estimated to affect 1 in 4 by 2050. Treatment relies on the accurate diagnosis of hearing loss; however, this first step is out of reach for >80% of those affected. Increasingly automated approaches are being developed for self-administered digital hearing assessments without the direct involvement of professionals. Objective: This study aims to provide an overview of digital approaches in automated and machine learning assessments of hearing using pure-tone audiometry and to focus on the aspects related to accuracy, reliability, and time efficiency. This review is an extension of a 2013 systematic review. Methods: A search across the electronic databases of PubMed, IEEE, and Web of Science was conducted to identify relevant reports from the peer-reviewed literature. Key information about each report’s scope and details was collected to assess the commonalities among the approaches. Results: A total of 56 reports from 2012 to June 2021 were included. From this selection, 27 unique automated approaches were identified. Machine learning approaches require fewer trials than conventional threshold-seeking approaches, and personal digital devices make assessments more affordable and accessible. Validity can be enhanced using digital technologies for quality surveillance, including noise monitoring and detecting inconclusive results. Conclusions: In the past 10 years, an increasing number of automated approaches have reported similar accuracy, reliability, and time efficiency as manual hearing assessments. New developments, including machine learning approaches, offer features, versatility, and cost-effectiveness beyond manual audiometry. Used within identified limitations, automated assessments using digital devices can support task-shifting, self-care, telehealth, and clinical care pathways.
29 August 2023 in Ear & Hearing
Objectives: The stability of remote testing in cochlear implant care was studied by testing the influence of time-of-day, listener fatigue, and motivation on the outcomes of the aided threshold test (ATT) and digit triplets test (DTT) in cochlear implant (CI) recipients using self-tests at-home on a smartphone or tablet. Design: A single-center repeated measures cohort study design (n = 50 adult CI recipients). The ATT and DTT were tested at-home ten times, with nine of these sessions planned within a period of eight days. Outcomes were modeled as a function of time-of-day, momentary motivation, listeners’ task-related fatigue, and chronotype (i.e., someone’s preference for morning or evening due to the sleep-wake cycle) using linear mixed models. Additional factors included aided monosyllabic word recognition in quiet, daily-life fatigue, age, and CI experience. Results: Out of 500 planned measurements, 407 ATTs and 476 DTTs were completed. The ATT determined thresholds and impedances were stable across sessions. The factors in the DTT model explained 75% of the total variance. Forty-nine percent of the total variance was explained by individual differences in the participants’ DTT performance. For each 10% increase in word recognition in quiet, the DTT speech reception threshold improved by an average of 1.6 dB. DTT speech reception threshold improved, on average by 0.1 dB per repeated session and correlated with the number of successful DTTs per participant. There was no significant time-of-day effect on auditory performance in at-home administered tests. Conclusions: This study is one of the first to report on the validity and stability of remote assessments in CI recipients and reveals relevant factors. CI recipients can be self-tested at any waking hour to monitor performance via smartphone or tablet. Motivation, task-related fatigue, and chronotype did not affect the outcomes of ATT or DTT in the studied cohort. Word recognition in quiet is a good predictor for deciding whether the DTT should be included in an individual’s remote test battery. At-home testing is reliable for cochlear implant recipients and offers an opportunity to provide care in a virtual hearing clinic setting.
1 January 2020 in Hearing Research
1 January 2020 in MethodsX
In this paper, a mobile sound localization setup is described that can be used to measure a persons’ localization performance in a sophisticated way. With this mobile setup, researchers can travel to subjects, and studies are not limited by the willingness of participants to visit the clinic. In the setup, sounds are presented within a partial sphere in both the horizontal (−70° to 70° azimuth) and vertical (−35° to 40° elevation) plane. Participants are asked to indicate the perceived sound origin by pointing with a head-mounted LED. Head movements are recorded and instantly visualized (i.e. online target response plots). Depending on the research question, the setup can be adjusted for more advanced or simplified measurements, making the setup suitable for a wide range of research questions. The rationale for building this mobile setup was to test horizontal sound localization abilities (binaural hearing) and vertical sound localization abilities (monaural hearing) of children and patients who were otherwise not accessible for testing. In this setup loudspeakers are not visible and subjects are asked to indicate the perceived sound direction by a natural head-pointing response towards the perceived location. An advantage of the implemented pointing-method is the playful manner in which children are tested. They are ‘shooting’ at the perceived sound target location with a head-mounted LED and have fun while performing the test.
28 January 2026 in International Journal of Audiology
This study addresses conceptual issues around data standardisation in audiology, and outlines steps towards achieving it. It reports a survey of the computational audiology community on their current understanding, needs, and preferences concerning data standards. Based on survey findings and a panel discussion, recommendations are made concerning moving forward with standardisation in audiology. Mixed-methods: (1) review of existing standardisation efforts; (2) a survey of the computational audiology community; (3) expert panel discussion in a dedicated session at the 2024 Virtual Conference of Computational Audiology. Survey: 82 members of the global community; Panel discussion: five experts. A prerequisite for any global audiology database are agreed data standards. Although many are familiar with the general idea, few know of existing initiatives, or have actively participated in them. Ninety percent of respondents expressed willingness to follow or contribute to standardisation efforts. The panel discussed relevant initiatives (e.g. OMOP, openEHR, Noah) and explored both challenges (around harmonisation) and opportunities (alignment with other medical fields and conversion among approaches). Combining conceptual discussion with stakeholder views, the study offers guidance for implementing interoperable data standards in audiology. It highlights community support, key issues to address, and suggests paths for future work.