Zhao Zheng

Zhao Zheng

Auto-generated profile, based on publicly available information

Zhao Zheng

Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZZZhao Zheng
Zhao Zheng
JFJingfan Fan
Jingfan Fan
LSLong Shao
Long Shao
HYHeqiang Yang
Heqiang Yang
LZLiming Zhao
Liming Zhao
JYJian Yang
Jian Yang
Binocular camera is widely used in high-accuracy 3-D measurement and the systematic error is critically determined by the calibration of camera parameters. This article proposes a binocular camera calibration method based on planar target with different orientations translating along single axis. The translation of planar target composes a calibration grid, which is localized in an affine coordinate system (ACS). In addition, nonhomogeneous projection equations of binocular camera indicate the relationship between ACS and image projection coordinate system (IPCS). Therefore, a linear estimation of binocular camera parameters is obtained. In addition, we collect multiple calibration grids with different orientations to improve the estimation accuracy of principal points. Finally, we minimize reprojection error to optimize these camera parameters. Simulation and application experiments demonstrate that our method achieves less focal length error (0.063 pixel) than traditional calibration method using arbitrary placed planar target (0.123 pixel), and less principal point error (0.220 pixel) than pure translation method (0.271 pixel).

26 September 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ZZZhao Zheng
Zhao Zheng
JFJingfan Fan
Jingfan Fan
LSLong Shao
Long Shao
XZXiaocai Zhang
Xiaocai Zhang
HSHong Song
Hong Song
JYJian Yang
Jian Yang
Objective: Optical tracking system (OTS) localizes the position of rigid surgical tools attached with retro-reflective markers in image-guided surgery (IGS). IGS uses marker-based probes to collect points per frame, or attaches a coordinate reference frame (CRF) on a 3D camera to indirectly measure the surface of patient. However, these measurement methods involve compressive deformation errors from probes or calibration errors from 3D camera to OTS. Methods: This paper designs a simultaneous reconstruction and tracking framework for the markered tools and markerless surfaces in the indoor environment without calibration between measurement devices and OTS. A synchronized near-infrared (NIR) digital light projector (DLP) is integrated with OTS, and projects phase-shifting fringe patterns to the target surface. Surgical tools and surface are simultaneously tracked in the same coordinate system of OTS. The reconstructed surface is then registered to CT image space and corrects the intraoperative motion for mixed reality guided surgery. Results: The proposed method is compared with conventional measurement methods using calibrated devices in image-patient registration experiments, and they are evaluated with target registration error (TRE). The TRE of the proposed method is 0.805$\pm$0.152 mm in quantitative phantom experiments and 1.328$\pm$0.318 mm in qualitative cadaveric specimen experiments respectively, achieving the best performance among comparison methods in the phantom experiments. Conclusion: It demonstrates that our approach has the ability to enhance the registration accuracy and efficiency of IGS due to the noncontact and uncalibrated tracking.

21 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SCSifan Cao
Sifan Cao
JFJingfan Fan
Jingfan Fan
YYYun Yang
Yun Yang
DLDawei Lu
Dawei Lu
ZZZhao Zheng
Zhao Zheng
JYJian Yang
Jian Yang
Accurate intraoperative localization of luminal tumors is crucial for effective resection. However, the limited field of view of endoscopes hinders lesion visualization from the external operative perspective. Furthermore, existing endoscopic fusion navigation techniques struggle to align endoscopic images with preoperative CT scans after deformation of flexible organs. To address this, we propose a novel tumor-augmented imaging method that reconstructs tumor morphology from Intracavitary Endoscopy (IE) images and, by leveraging spatial relationships among sensors, fuses the lesion onto multiple non-fixed Laparoscopic/ Scene Cameras (L/SCs). To mitigate multi-source uncertainties in calibrating external visual coordinate systems, we proposed a graph-optimization-based multi-loop constraint calibration framework. The framework is first modeled as a directed graph, followed by a parameter-sharing strategy leveraging a covariance-weighted approach to quantitatively characterize sensor uncertainty. Building on this, a reprojection error function is constructed for multiple non-fixed camera systems to globally optimize the hand-eye calibration matrix, enabling accurate fusion of tumors reconstructed from absolute tracking data into their corresponding positions in the external views. Experiments on self-built and public calibration datasets demonstrate state-of-the-art accuracy and strong robustness to sensor noise. Ex vivo studies validate the reliability of tumor fusion onto external views, providing a novel fusion-guided surgery navigation method for intraoperative tumor localization.

19 May 2023
Verified
Conference Paper
Open access
ZLZiheng Li
Ziheng Li
ZZZhao Zheng
Zhao Zheng
SLShaojie Liu
Shaojie Liu
JFJingfan Fan
Jingfan Fan
JYJian Yang
Jian Yang
Medical intelligent navigation systems have attracted increasing attention, and binocular optical tracking systems being an important component to ensure accurate tracking navigation. However, ghost markers may appear when there are multiple markers on the same plane, which can result in tracking errors and significantly impact the surgical process. In this paper, we propose a robust stereo matching algorithm based on spatial constraints under rectification. The algorithm is verified using a binocular vision system based on Xilinx Zynq-7020 platform of field-programmable gate array (FPGA), which meets the requirement of fast, real-time tracking of multiple instruments. The used matching algorithm has a tracking processing time of only 107 under four surgical instruments, which is 82.46% higher than the epipolar geometry method. Furthermore, compared with the traditional sequential matching method, this method improves the tracking failure rate by 6.46% for tracking four instruments, effectively avoiding false matching caused by the appearance of ghost markers.