21 October 2022 in Journal of Stomatology Oral and Maxillofacial Surgery
18 November 2024 in IEEE Transactions on Circuits and Systems for Video Technology
The structured light (SL)-based three-dimensional (3D) measurement techniques with deep learning have been widely studied to improve measurement efficiency, among which fringe projection profilometry (FPP) and speckle projection profilometry (SPP) are two popular methods. However, they generally use a single projection pattern for reconstruction, resulting in fringe order ambiguity or poor reconstruction accuracy. To alleviate these problems, we propose a parallel dual-branch Convolutional Neural Network (CNN)-Transformer network (PDCNet), to take advantage of convolutional operations and self-attention mechanisms for processing different SL modalities. Within PDCNet, a Transformer branch is used to capture global perception in the fringe images, while a CNN branch is designed to collect local details in the speckle images. To fully integrate complementary features, we design a double-stream attention aggregation module (DAAM) that consists of a parallel attention subnetwork for aggregating multi-scale spatial structure information. This module can dynamically retain local and global representations to the maximum extent. Moreover, an adaptive mixture density head with bimodal Gaussian distribution is proposed for learning a representation that is precise near discontinuities. Compared to the standard disparity regression strategy, this adaptive mixture head can effectively improve performance at object boundaries. Extensive experiments demonstrate that our method can reduce fringe order ambiguity while producing high-accuracy results on self-made datasets.
11 April 2024 in IEEE Transactions on Instrumentation and Measurement
Binocular camera is widely used in high-accuracy 3-D measurement and the systematic error is critically determined by the calibration of camera parameters. This article proposes a binocular camera calibration method based on planar target with different orientations translating along single axis. The translation of planar target composes a calibration grid, which is localized in an affine coordinate system (ACS). In addition, nonhomogeneous projection equations of binocular camera indicate the relationship between ACS and image projection coordinate system (IPCS). Therefore, a linear estimation of binocular camera parameters is obtained. In addition, we collect multiple calibration grids with different orientations to improve the estimation accuracy of principal points. Finally, we minimize reprojection error to optimize these camera parameters. Simulation and application experiments demonstrate that our method achieves less focal length error (0.063 pixel) than traditional calibration method using arbitrary placed planar target (0.123 pixel), and less principal point error (0.220 pixel) than pure translation method (0.271 pixel).
22 April 2025 in IEEE Transactions on Circuits and Systems for Video Technology
Facial point clouds collected in practical applications often suffer from pose variations and occlusion. Existing studies typically focus on either pose estimation or landmarks localization, neglecting to fully utilize the effective information from various facial features, thus limiting the improvement of prediction accuracy. Therefore, we propose an innovative 3D facial multi-task prediction network. The proposed network embeds the output of related tasks into feature extraction from the point level to the global level based on the physical dependencies between tasks. This facilitates explicit multi-task knowledge transfer, enabling the simultaneous prediction of facial landmarks, occlusion, and head pose. We introduce a training strategy based on posterior knowledge correction to iteratively refine and improve multi-task prediction results. Moreover, no single dataset provides annotations for all these tasks at once, so we synthesized a 3D landmarks, occlusion and pose (3D-LOP) dataset, which includes annotations for landmarks coordinates, occlusion probability, and head pose. The proposed method was compared with state-of-the-art methods on two public datasets and 3D-LOP. The landmarks localization accuracy improved by 7.1% on the two public datasets, and the pose estimation accuracy and stability on 3D-LOP improved by 28.5% and 32.7%, respectively. The performance on wild data also shows its potential in practical applications.
8 April 2025 in IEEE Transactions on Circuits and Systems for Video Technology
The application of structured light (SL) techniques has achieved remarkable success in three-dimensional (3D) measurements. Traditional methods generally calculate SL information pixel by pixel to obtain the measurement results. Recently, the rise of deep learning (DL) has led to significant developments in this task. However, existing DL-based methods generally learn all features within the image in an end-to-end manner, ignoring the distinction between SL and non-SL information. Therefore, these methods may encounter difficulties in focusing on subtle variations in SL patterns across different scenes, thereby degrading measurement precision. To overcome this challenge, we propose a novel SL Image Planar-Topography Feature Decomposition Network (SIDNet). To fully utilize the information from different SL modality images (fringe and speckle), we decompose different modalities into topography features (modality-specific) and planar features (modality-shared). A physics-driven decomposition loss is proposed to make the topography/planar features dissimilar/similar, which guides the network to distinguish between SL and non-SL information. Moreover, to obtain modality-fused features with global overview and local detail information, we propose a wrapped phase-driven feature fusion module. Specifically, a novel Tri-modality Mamba block is designed to integrate different sources with the guidance of the wrapped phase features. Extensive experiments demonstrate the superiority of our SIDNet in multiple simulated 3D measurement scenes. Moreover, our method shows better generalization ability than other DL models and can be directly applicable to unseen real-world scenes.
26 September 2025 in IEEE Transactions on Biomedical Engineering
Objective: Optical tracking system (OTS) localizes the position of rigid surgical tools attached with retro-reflective markers in image-guided surgery (IGS). IGS uses marker-based probes to collect points per frame, or attaches a coordinate reference frame (CRF) on a 3D camera to indirectly measure the surface of patient. However, these measurement methods involve compressive deformation errors from probes or calibration errors from 3D camera to OTS. Methods: This paper designs a simultaneous reconstruction and tracking framework for the markered tools and markerless surfaces in the indoor environment without calibration between measurement devices and OTS. A synchronized near-infrared (NIR) digital light projector (DLP) is integrated with OTS, and projects phase-shifting fringe patterns to the target surface. Surgical tools and surface are simultaneously tracked in the same coordinate system of OTS. The reconstructed surface is then registered to CT image space and corrects the intraoperative motion for mixed reality guided surgery. Results: The proposed method is compared with conventional measurement methods using calibrated devices in image-patient registration experiments, and they are evaluated with target registration error (TRE). The TRE of the proposed method is 0.805$\pm$0.152 mm in quantitative phantom experiments and 1.328$\pm$0.318 mm in qualitative cadaveric specimen experiments respectively, achieving the best performance among comparison methods in the phantom experiments. Conclusion: It demonstrates that our approach has the ability to enhance the registration accuracy and efficiency of IGS due to the noncontact and uncalibrated tracking.