Margaret Sietsema

Margaret Sietsema

Auto-generated profile, based on publicly available information

Margaret Sietsema

M (United States)

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MPMaryam Pishgar
Maryam Pishgar
SISalah F. Issa
Salah F. Issa
MSMargaret Sietsema
Margaret Sietsema
PPPreethi Lakshmi Pratap
Preethi Lakshmi Pratap
Houshang DarabiHoushang Darabi
Houshang Darabi
Introduction: The field of artificial intelligence (AI) is rapidly expanding, with many applications seen routinely in health care, industry, and education, and increasingly in workplaces. Although there is growing evidence of applications of AI in workplaces across all industries to simplify and/or automate tasks there is a limited understanding of the role that AI contributes in addressing occupational safety and health (OSH) concerns. Methods: This paper introduces a new framework called Risk Evolution, Detection, Evaluation, and Control of Accidents (REDECA) that highlights the role that AI plays in the anticipation and control of exposure risks in a worker’s immediate environment. Two hundred and sixty AI papers across five sectors (oil and gas, mining, transportation, construction, and agriculture) were reviewed using the REDECA framework to highlight current applications and gaps in OSH and AI fields. Results: The REDECA framework highlighted the unique attributes and research focus of each of the five industrial sectors. The majority of evidence of AI in OSH research within the oil/gas and transportation sectors focused on the development of sensors to detect hazardous situations. In construction the focus was on the use of sensors to detect incidents. The research in the agriculture sector focused on sensors and actuators that removed workers from hazardous conditions. Application of the REDECA framework highlighted AI/OSH strengths and opportunities in various industries and potential areas for collaboration. Conclusions: As AI applications across industries continue to increase, further exploration of the benefits and challenges of AI applications in OSH is needed to optimally protect worker health, safety and well-being.

7 November 2014 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
LBLisa M. Brosseau
Lisa M. Brosseau
LCLorainne Conroy
Lorainne Conroy
MSMargaret Sietsema
Margaret Sietsema
KCKari Cline
Kari Cline
KDKara Durski
Kara Durski
The objective of this study was to assess respiratory protection programs for aerosol-transmissible diseases in acute care hospitals for conformance with regulatory requirements and public health guidelines. Twenty-eight representative hospitals were selected by size, location, and ownership in Minnesota and Illinois. Interviews were conducted with 363 health care workers and 171 managers from high-risk departments. Written programs from each hospital were reviewed for required elements. Seventy-seven health care workers were observed donning and doffing a FFR. The most serious deficiency in many written programs was failure to identify a program administrator. Most written programs lacked adequate details about medical evaluation, fit-testing, and training and did not include a comprehensive risk assessment for aerosol transmissible diseases; tuberculosis was often the only pathogen addressed. Employees with the highest probability of tuberculosis exposure were most likely to pick a respirator for close contact, but higher levels of respiratory protection were rarely selected for aerosol-generating procedures. Surgical masks were most commonly selected for close contact with droplet disease- or influenza-infected patients; better protection (e.g., respirator) was rarely selected for higher-risk exposures. Most of the observed health care workers had access to a NIOSH-certified N95 FFR, properly positioned the facepiece, and formed the nose clip. The most frequent deficiencies were failure to correctly place straps, perform a user seal check, and remove the respirator using straps.

1 April 2019 in Health Security
Verified
Journal Article
Closed access
MSMargaret Sietsema
Margaret Sietsema
LRLew Radonovich
Lew Radonovich
FHFrank J. Hearl
Frank J. Hearl
EFEdward M. Fisher
Edward M. Fisher
LBLisa M. Brosseau
Lisa M. Brosseau
LKLisa M. Koonin
Lisa M. Koonin
Recent high-profile infectious disease outbreaks illustrate the importance of selecting appropriate control measures to protect a wider range of employees, other than those in healthcare settings. In such settings, where routine exposure risks are often high, control measures may be more available, routinely implemented, and studied for effectiveness. In the absence of evidence-based guidelines or established best practices for selecting appropriate control measures, employers may unduly rely on personal protective equipment (PPE) because of its wide availability and pervasiveness as a control measure, circumventing other effective options for protection. Control banding is one approach that may be used to assign job tasks into risk categories and prioritize the application of controls. This article proposes an initial control banding framework for workers at all levels of risk and incorporates a range of control options, including PPE. Using the National Institutes of Health (NIH) risk groups as a surrogate for toxicity and combining the exposure duration with the exposure likelihood, we can generate the risk of a job task to the worker.

2 December 2018 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
MSMargaret Sietsema
Margaret Sietsema
LBLisa M. Brosseau
Lisa M. Brosseau
An annual OSHA fit test is required for all U.S. employees required to wear a respirator during work, but there are limited data demonstrating a link between fit test results and respirator fit during work. The goal of this research is to determine if the fit factor (FF) achieved during an abbreviated ambient aerosol condensation particle counter (CPC) quantitative fit test is predictive of fit achieved during a simulated workplace protection factor (SWPF) scenario that includes realistic healthcare activities. Fifteen subjects (7 male; 8 female) were recruited for a range of facial sizes. Each subject donned an N95 filtering facepiece respirator and performed a single 29-min routine consisting of initial and final 2.5 min fast fit tests (five 30-sec exercises: normal breathing, head side to side, head up and down, talking, and bending over) and three repetitions of three 6-min simulated healthcare activities (CPR, ultrasound, and making a hospital bed). Two CPC instruments simultaneously collected second-by-second measures of particle concentration inside and outside of the respirator facepiece. FFs or SWPFs were calculated by dividing outside by inside facepiece concentrations. Overall FFs and SWPFs were highly correlated. Each exercise FF was highly correlated with the overall SWPF. Normal breathing, head up and down, and talking were most predictive of overall SWPF. Normal breathing and talking together were predictive of each of the three simulated healthcare activities. For CPR and bed making activities, head movement exercises were also found to be predictive. A quantitative fit test using a small set of exercises is highly predictive of an individual’s fit during simulated work activities. Some exercises (e.g. talking and head movements) are predictive of fit during simulated workplace activities. Limitations include only one respirator model, a small subject pool not representative of the full range of face sizes. This paper uses an innovative second-by-second assessment method that collects information about in- and outside-facepiece concentrations throughout the test period.

23 June 2017 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
BRBrian Rembialkowski
Brian Rembialkowski
MSMargaret Sietsema
Margaret Sietsema
LBLisa Brosseau
Lisa Brosseau
The goal of this study was to examine the impact of assistance with donning and time on quantitative fit factors (FF) and pass rates for subjects wearing an N95 filtering facepiece respirator (FFR) and a non-certified adhesive mask. Fit factors were measured using two side-by-side TSI Portacount instruments sampling second-by-second simultaneous inside- and outside-facepiece concentrations. Naïve subjects made two visits at least one week apart. At each visit subjects first donned either the respirator or adhesive mask without assistance and performed a five-exercise fast fit test. They then donned a new respirator or mask with assistance in proper donning (e.g., proper forming of the nosepiece, strap placement, etc.) and performed a second five-exercise fast fit test. The same sequence of unassisted and assisted donning was then repeated with the other facepiece. Fifteen subjects participated in the study; time between visits ranged from 7–29 days (average 12 days). On visit 1 the respirator FFs were significantly higher (GM = 88) than for the adhesive mask (GM = 14); with assistance these FFs showed significant improvements to 116 and 124, respectively. At visit 1 almost half of subjects donning the respirator without assistance achieved a passing FF of 100 or greater, while only one-fifth of subjects were able to pass the fit test wearing an adhesive mask without assistance. Pass rates improved for both groups with assistance, but more so for the adhesive mask wearers. On visit 2 the pass rates for both groups had decreased, with the adhesive mask group showing a greater decrease. With assistance, pass rates improved for both groups, but again more so for those wearing the adhesive mask. Results suggest that wearers would benefit from assistance and re-training every time they don a respirator, even if the time between donnings is as short as one or two weeks.

15 December 2022 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Open access
MSMargaret Sietsema
Margaret Sietsema
HHHamed Hamza
Hamed Hamza
LBLisa M. Brosseau
Lisa M. Brosseau
The assigned protection factor (APF) for quarter facepiece respirators is currently 5, based on fit test data from the 1970s with models no longer commercially available. The goal of this project was to evaluate the respirator fit capability of a NIOSH-approved N95 quarter facepiece elastomeric respirator with a gel-based facial seal design (Envo® Mask by Sleepnet Corporation). Human subjects were recruited from healthcare and the general population to satisfy a 25-member NIOSH bivariate panel. Subjects were fit tested with a fast fit protocol using a TSI Portacount Model 8038 in the N95 mode. Second-by-second measures of fit were then collected while subjects performed a 30-min series of simulated healthcare activities. Subjects completed a short comfort questionnaire. The median (5th, 95th percentile) fit factor was 188 (48, 201). Simulated workplace protection factors (SWPFs) had a median (5th, 95th percentile) of 181 (94, 199) (data truncated at 200) and 570 (153, 1508) (non-truncated data). Subjects ranked inhalation and exhalation as “easy” with average scores of 5.0/6.0 and 5.2/6.0, respectively. The facepiece was ranked between slightly comfortable and comfortable (4.8/6.0) and the harness as comfortable (5.0/6.0). Most users agreed (5.2/6.0) that the mask was stable on their face. The 5th percentile SWPF of 95 supports an APF of at least 10 for this quarter facepiece elastomeric respirator, similar to the APF for half facepiece respirators. This study supports increasing the APF for quarter facepiece respirators, a class that has been largely ignored by manufacturers for the past 40 years. A lightweight, low profile, reusable quarter facepiece respirator is an effective option for healthcare and other worker protection during pandemic and similar situations.