Meinhard Schilling

Meinhard Schilling

Auto-generated profile, based on publicly available information

Meinhard Schilling

Institut fr Elektrische Messtechnik und Grundlagen der Elektrotechnik, Technische Universitt Braunschweig, Braunschweig, Germany

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2018 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
GGGabriel Pieter Greeff
Gabriel Pieter Greeff
MSMeinhard Schilling
Meinhard Schilling

1 April 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MTM. Tollkühn
M. Tollkühn
PRP. J. Ritter
P. J. Ritter
MSM. Schilling
M. Schilling
BHB. Hampel
B. Hampel
Superconducting Josephson junctions have a wide range of applications ranging from quantum computing to voltage standards, and they may also be employed as versatile sensors for high-frequency radiation and magnetic fields. In this work, we present a unique measurement setup utilizing a single Josephson junction on a cantilever for high-resolution spatial measurements of spectroscopically resolved THz and microwave field distributions. This THz microscope can be utilized to measure power and frequency of electromagnetic radiation from ∼1 GHz to 5 THz. It may also be used to measure static magnetic fields and provide topological scans of samples. The samples can be both actively radiating or passively irradiated at either room temperature or cryogenic temperatures. We review the measurement setup of the THz microscope and describe the evaluation of its measurement data to achieve three-dimensional visualizations of the field distributions. The diverse capabilities of this unique tool are demonstrated by its different measurement modes with measurements of field distributions at 20 GHz and 1.4 THz, spectroscopically resolved THz measurements, and magnetic field measurements.

12 December 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MPMax Pröpper
Max Pröpper
DHDominik Hanisch
Dominik Hanisch
CSChristoph Schmid
Christoph Schmid
MNMarius Neumann
Marius Neumann
PRPaul Julius Ritter
Paul Julius Ritter
BHBenedikt Hampel
Benedikt Hampel
The development of a fabrication process for Josephson junctions (JJs) using a direct-write helium-focused ion beam (He-FIB) technique provides the opportunity to control parameters such as the critical current $I_{\mathrm{c}}$ and normal-state resistance $R_{\mathrm{n}}$ of individual JJs in YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJ arrays. Such arrays could be used as a voltage calibration standard that is operated at higher temperatures and higher driving frequencies than the currently used niobium JJ arrays. This study presents the fabrication process of 79 YBa$_{2}$Cu$_{3}$O$_{7-\mathrm{x}}$ JJs in a meander array design using a direct writing He-FIB process with the same irradiation dose for all JJs. In this design, each of the JJs can be measured individually, and adjacent JJs that exhibit similar and suitable parameters for a voltage standard array can be measured in series. The scattering of the JJ parameters was investigated at 5 K and resulted in a spread in $I_{\mathrm{c}}$ of about 60% and in $R_{\mathrm{n}}$ of 25%. However, a couple of subarrays with a spread lower than 10% could be found. In addition, these JJ subarrays were irradiated with high-frequency radiation in the GHz and THz range at a temperature of 20 K and synchronization of up to three JJs was observed in both frequency ranges.

23 September 2019 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JZJing Zhong
Jing Zhong
NLNiklas Lucht
Niklas Lucht
BHBirgit Hankiewicz
Birgit Hankiewicz
MSMeinhard Schilling
Meinhard Schilling
FLFrank Ludwig
Frank Ludwig
This paper investigates the dynamic ac susceptibility (ACS) and the Brownian relaxation time of magnetic nanoparticles (MNPs) in dc magnetic fields with arbitrary orientations with respect to the ac magnetic field. A CoFe2O4 MNP sample, dominated by Brownian relaxation, is used to perform ACS measurements in an ac magnetic field with a constant amplitude of 0.2 mT (from 2 to 3000 Hz) and a superposed dc magnetic field with amplitudes ranging from 0 to 5 mT. Experimental results indicate that the ACS and Brownian relaxation time are significantly affected not only by the strength but also by the orientation of the dc magnetic field. Moreover, a mathematical model is proposed to analyze the ACS and Brownian relaxation time in dependence of the orientation of the dc magnetic field, which extends the established models parallel or perpendicular to arbitrary-oriented dc magnetic fields. Experimental results indicate that the good fitting between the experimental data (ACS and Brownian relaxation time) and the proposed models demonstrates the feasibility of the proposed model for the description of ACS and Brownian relaxation time in arbitrary-orientated ac and dc magnetic fields.

1 June 1999 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SKS. Krey
S. Krey
OBO. Brugmann
O. Brugmann
HBH. Burkhardt
H. Burkhardt
MSM. Schilling
M. Schilling

15 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SSShijie Sun
Shijie Sun
YCYaoyao Chen
Yaoyao Chen
KJKlaas-Julian Janssen
Klaas-Julian Janssen
TVThilo Viereck
Thilo Viereck
MSMeinhard Schilling
Meinhard Schilling
JZJing Zhong
Jing Zhong
Magnetic particle imaging (MPI) is an emerging medical imaging technique that measures the nonlinear magnetization response of magnetic nanoparticles (MNPs). The image reconstruction of MPI is to solve the unknown spatial distribution of MNPs from the measured magnetic response signal, which plays a significant role in MPI. In this study, a sparse-representation-based image reconstruction method is proposed to improve the spatial resolution and reduce the artifacts of MPI images. In the proposed method, the spatial distribution of MNPs is sparsely represented by the Gaussian radial basis functions (GRBFs). The inverse problem in MPI is consequently transformed to obtain the optimal weight coefficient vector of the GRBFs. It helps to reduce the number of unknowns to be reconstructed and improve the robustness of the image reconstruction process. By incorporating the prior knowledge from the preliminary reconstructed images, the center points of the GRBFs are selected densely in the target area and sparsely outside to further reduce the dimension of the system matrix and the artifacts. Numerical simulations are performed to optimize the key parameters in the proposed method. Furthermore, phantom experiments are carried out using a single-harmonic-based narrowband MPI scanner to demonstrate the feasibility of the proposed method. Experimental results show that the proposed method improves the spatial resolution from 0.5 to 0.3 mm and reduces the artifacts compared with the algebraic reconstruction technique (ART) method and the Newton-Raphson method. We envisage that the proposed method is of great significance to biomedical applications for MPI.