Vishal Anand

Vishal Anand

Auto-generated profile, based on publicly available information

Vishal Anand

Department of Electrical Engineering National Institute of Technology Raipur India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
VAVishal Anand
Vishal Anand
VSVinay Pratap Singh
Vinay Pratap Singh
In this article, a novel 13-level inverter Single source, Switched-Capacitor Multi-Level Inverter (SSC-MLI), is proposed. This topology is suitable for renewable energy applications using less input voltage source magnitude. This structure is capable of boosting the input voltage six times with the help of switched capacitors. The capacitors are automatically balanced without any control algorithms, complex circuits, or closed-loop controllers. The advantages of the proposed structure are high power density and high efficiency by use of only switches. Since, there is no diodes there is no forward conduction loss, and no reverse recovery delay. The maximum blocking voltage across individual switch is three times the input voltage. The functionality of the SSC-MLI is described in detail. The capacitance calculation and optimum value of capacitors are discussed. A suitable comparison is presented for the proposed structure with the existing literature to check the inverter performance. The power loss for exiting a 13-level inverter is presented. The simulation is carried out for both pure resistive and inductive load. Later, the experimental results are presented for variation in frequency, dynamic change in load, variation in modulation index, and step-change in input voltage to validate the proposed topology performance and feasibility.

20 April 2022 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
VAVishal Anand
Vishal Anand
VSVinay Pratap Singh
Vinay Pratap Singh
MSMAJ Sathik
MAJ Sathik
This brief presents a five-level common ground type (5L-CGT) inverter topology with double voltage boosting. This topology uses only eight switches, two capacitors that can be charged equal to the input source. The advantageous feature of this topology is the CGT configuration between the input source and output load, which ensures minimal common-mode voltage and leakage current. A detailed analysis is done to select and size capacitors, along with quasi-soft charging to minimize the charging current ripples across the capacitors. The performance of the proposed 5L-CGT inverter is tested for inductive load, varying the modulation index/load/input voltage under experimental test conditions. A detailed comparison is done with the existing state-of-art that shows the merits of the proposed topology in terms of equal voltage stress across the capacitor with voltage boost. The power loss analysis for the inverter is carried out using PLECS with efficiency to be 97.20%, and the experimental efficiency is found to be 96.54% for the 900W inverter prototype.

18 May 2020 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
VAVishal Anand
Vishal Anand
VSVinay Pratap Singh
Vinay Pratap Singh

4 July 2023 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
VAVishal Anand
Vishal Anand
VSVinay Pratap Singh
Vinay Pratap Singh
XGXiaoqiang Guo
Xiaoqiang Guo
MSMAJ Sathik
MAJ Sathik
Yam SiwakotiYam Siwakoti
Yam Siwakoti
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
The topology of a 17-level (17 L) hybrid switched-capacitor multilevel inverter (SCMLI) with high voltage gain is presented in this work. A single source, four capacitors, six half-bridge switches (five with anti-parallel diodes and one half-bridge without anti-parallel diodes), and five diodes is used in the proposed SCMLI. The total standing voltage (TSV), cost function (CF), and maximum blocking voltage (MBV) across the switches and capacitors are all reduced by this inverter. The MBV is half the output voltage, lowering component costs and reducing the overall size of the inverter to achieve high power density. In addition, a soft-charging approach has been implemented to reduce the current stress on the components. The proposed SCMLI advantages over current state-of-the-art 17 L inverters are fully examined in terms of TSV, CF, and MBV. To determine the viability of the proposed 17 L inverter, several experimental tests on a 1 kW laboratory prototype are conducted.

21 November 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
SNSukhdev Singh Neti
Sukhdev Singh Neti
VSVinay Pratap Singh
Vinay Pratap Singh
VAVishal Anand
Vishal Anand
The presented brief introduces a new switched capacitor-based transformer-less inverter (SC TLI). This SC TLI configuration is based on a reduced switch count employing only six switches, one of which is a bidirectional switch. It uses only one power source and two SCs to obtain a five-level output voltage. A level shift pulse width modulation (LS-PWM) based simple logic circuit controls SC TLI. It also handles capacitor charging and discharging during operation for each fundamental cycle. The SCs are self-balanced and do not require any specific controller. Further, detailed comparative studies are performed with existing arts of literature to determine the merits of the SC TLI. A prototype SC TLI model is made in the laboratory. The experimental results from the laboratory prototype validate the feasibility of the SC TLI. The voltage, current stress, and junction temperature across the power component are analyzed for the SC TLI design. Finally, this SC TLI performance characteristic is presented for different loading conditions.

9 August 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
VAVishal Anand
Vishal Anand
MSMAJ Sathik
MAJ Sathik
Cristian GarciaCristian Garcia
Cristian Garcia
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Jose RodriguezJose Rodriguez
Jose Rodriguez
This article proposes two nineteen-level active neutral point clamped self-balanced switched capacitor multilevel inverter (19L-ANPC-SCMLI) topologies for high-frequency AC power distribution systems (HFAC PDS). Since the proposed topologies have boosting ability, each topology employs four switched capacitor (SC) cells to boost the input voltage. In addition to this, two DC-link capacitors, bidirectional switches, and diodes are used. The Selective Harmonic Elimination (SHE) modulation technique controls the functioning of the inverter. Further, it has a low device count, reduced voltage stress on power components, and self-balanced SCs do not require additional control algorithms and sensors to balance the capacitor voltages. Additionally, the higher number of voltage levels leads to lower harmonic distortion. A fair comparison of voltage gain, voltage stress, device count, and the number of capacitors against the number of levels is compared for the proposed topology and state-of-the-art 19L topologies. Later, the experiment results demonstrate the excellent performance of the proposed 19L-ANPC-SCMLI. Also, high efficiency is achieved, the maximum value is up to 94.42% at 500W for the laboratory setup.