R. Matthew Ferguson

R. Matthew Ferguson

Auto-generated profile, based on publicly available information

R. Matthew Ferguson

Lodespin Labs LLC, Seattle, WA 98103 USA

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
SKScott J. Kemp
Scott J. Kemp
RFR. Matthew Ferguson
R. Matthew Ferguson
AKAmit P. Khandhar
Amit P. Khandhar
KKKannan M. Krishnan
Kannan M. Krishnan
We present a scalable thermolysis and high temperature oxidation procedure for synthesizing monodisperse magnetite nanoparticles with saturation magnetization of up to 80 emu g −1 (412 kA m −1 ), 92% of bulk magnetite.

2 July 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
PVP. Vogel
P. Vogel
MRM. A. Ruckert
M. A. Ruckert
SKS. J. Kemp
S. J. Kemp
AKA. P. Khandhar
A. P. Khandhar
RFR. M. Ferguson
R. M. Ferguson
VBVolker C. Behr
Volker C. Behr
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.

1 July 1994 in American Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
RFRichard Ferguson
Richard Ferguson
SMStephen Myers
Stephen Myers
With more than 20,000 fetal deaths occurring annually in the United States, accurate epidemiological data concerning fetal death offer the potential to develop interventions aimed at saving a considerable number of fetuses. Currently, fetal death rates are determined by dividing the number of deaths by total births. These raw death rates do not focus on cause or preventability, nor do they delineate the risk for a individual pregnancy or any specific gestational age. Using data from 747,033 births in Illinois from 1984 to 1988, we estimated the fetal death risk (FDR) according to fetal weight and gestational age expressed as a function of the number of remaining fetuses. This procedure permits the comparison of FDR across all weights (including fetuses with growth retardation and macrosomia) and gestational ages. In addition, we examined the effect of race on this analysis. Between 28 and 36 weeks' gestational age, white fetuses with mean weights have a constant risk of fetal death at 0.1/1000 remaining fetuses. The risk is two to three times greater for black fetuses. If the fetus has growth retardation or is appropriately grown beyond 37 weeks' gestational age, the FDR increases further, with black fetuses remaining at higher risk. These data attempt to quantify the risk of fetal death. They support the widely held belief that the risk of fetal death increases in the presence of intrauterine growth retardation, but they also demonstrate that the risk of fetal death for all fetuses, including those appropriately grown, increases exponentially after 37 weeks' gestational age. Further research is needed to identify the causes of the observed racial differences in FDR, as well as those factors contributing to increased FDR within each race for appropriately grown, term fetuses.

1 March 2015
Verified
Conference Paper
Open access
PDF file
SKScott J. Kemp
Scott J. Kemp
RFR. Matthew Ferguson
R. Matthew Ferguson
AKAmit P. Khandhar
Amit P. Khandhar
KKKannan M. Krishnan
Kannan M. Krishnan
Magnetite nanoparticles with diameters of about 25-30 nm are promising candidates for magnetic particle imaging tracers. When preparing single-core tracers, controlling nanoparticle size and size distribution are critical. Thermal decomposition approaches can produce monodisperse nanoparticles over a range of sizes, but the reactions are kinetically driven monodisperse nanoparticles over a range of sizes, but the reactions are kinetically driven and sensitive to fluctuations that yield batch-to-batch variation in size and quality. Furthermore, if not carefully controlled, the reaction chemistry can produce variations in iron oxide phase and phase purity. Published protocols typically provide examples performed at small-scale and procedures that may not be scalable and frequently omit magnetic characterization that is critical for establishing suitability for MPI. Here, a scalable procedure for producing high quality, single-core magnetite nanoparticles that are confirmed to be suitable for MPI after rigorous characterization is presented. This work demonstrates that thermal decomposition synthesis of MPI tracers can be scaled without compromising quality to enable pre-clinical animal safety and efficacy studies.