2 July 2019 in IEEE Transactions on Magnetics
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.
25 March 2015 in IEEE Transactions on Magnetics
Since the introduction of magnetic particle imaging in 2005, several different types of scanner were presented. One of them is the traveling wave magnetic particle imaging (TWMPI) scanner. It uses for imaging a dynamic linear gradient array for a dynamic generation of a strong gradient and field free point. An unresolved issue of the TWMPI approach so far is the non-isotropic spatial resolution. As an alternative in this paper, a rotating slice scanning mode for TWMPI is presented to overcome this issue. This approach rotates the scanning-slices around the scanner axis and uses a projection reconstruction method to get a 3-D volume with a high isotropic resolution.
1 January 2021 in Physica Medica
12 October 2013 in Biomedical Engineering / Biomedizinische Technik
Current simulations of the signal in magnetic particle imaging (MPI) are either based on the Langevin function or on directly measuring the system function. The former completely ignores the influence of finite relaxation times of magnetic particles, and the latter requires time-consuming reference scans with an existing MPI scanner. Therefore, the resulting system function only applies for a given tracer type and the properties of the applied scanning trajectory. It requires separate reference scans for different trajectories and does not allow simulating theoretical magnetic particle suspensions. The most accessible and accurate way for including relaxation effects in the signal simulation would be using the Langevin equation. However, this is a very time-consuming approach because it calculates the stochastic dynamics of the individual particles and averages over large particle ensembles. In the current article, a numerically efficient way for approximating the averaged Langevin equation is proposed, which is much faster than the approach based on the Langevin equation because it is directly calculating the averaged time evolution of the magnetization. The proposed simulation yields promising results. Except for the case of small orthogonal offset fields, a high agreement with the full but significantly slower simulation could be shown.
1 January 2021 in TUGboat