Dong Wang

Dong Wang

Auto-generated profile, based on publicly available information

Dong Wang

Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen Universityhttps://ror.org/01vy4gh70, Shenzhen 518060, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2020 in IEEE Access
Verified
Journal Article
Open access
WFWenyong Fu
Wenyong Fu
JHJunkun Huang
Junkun Huang
DWDong Wang
Dong Wang
YLYunfei Lei
Yunfei Lei
YWYong Wang
Yong Wang
JLJinyuan Liu
Jinyuan Liu
A pulse dilation photomultiplier tube (PD-PMT) has been developed. The photoelectrons energy is modulated by a time-dependent electric field between photocathode and ground mesh. Then, the photoelectron pulse is dilated as it transits in a relatively long drift region from mesh to microchannel plate (MCP). The dilated electron pulse is gained by the MCP and then detected by the output collector. Because the temporal width is magnified, the temporal resolution of the photomultiplier tube is better than that of the output collector alone. The result shows that the temporal resolution of the detector is improved to be 25 ps by using pulse-dilation technology, which is much better than 300 ps temporal resolution while without pulse-dilation. The ramp electrical pulse dilates the electron signal to improve the temporal response by about 10 times.

19 October 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
QLQiuyan Luo
Qiuyan Luo
KLKaixuan Lin
Kaixuan Lin
JCJiajie Chen
Jiajie Chen
JWJiaheng Wang
Jiaheng Wang
JHJunkun Huang
Junkun Huang
HCHouzhi Cai
Houzhi Cai
Three magnetic focusing framing tubes are designed based on short magnetic lenses, long magnetic lenses, and hybrid lenses consisting of short and long magnetic lenses, and the spatial resolution characteristics of these framing tubes are theoretically studied. The excitation current of the short magnetic lenses is 0.15 A, the imaging magnification ratio is 1:1, and the spatial resolution is better than 50 $\mu $ m. The spatial resolution difference is 23.08% within the 30-mm off-axis. The spatial resolution of the long magnetic lens framing tube is better than 20 $\mu $ m, and the spatial resolution difference is 10.71%. However, the long magnetic lenses require a large excitation current of 26.25 A. For the hybrid magnetic lenses, the excitation current of 0.15 A is used to achieve a spatial resolution of better than 20 $\mu $ m and a spatial resolution difference of 8.11%. The simulation results show that the hybrid magnetic lenses are the best imaging method among these three lenses. A high spatial resolution and spatial resolution uniformity can be simultaneously obtained by using a small excitation current in the hybrid magnetic lens framing tube.

21 October 2021 in IEEE Access
Verified
Journal Article
Open access
JHJunkun Huang
Junkun Huang
DWDong Wang
Dong Wang
YLYunfei Lei
Yunfei Lei
YWYong Wang
Yong Wang
PDPokun Deng
Pokun Deng
JLJinyuan Liu
Jinyuan Liu
The energy distribution of output electrons (EDOE) from a microchannel plate (MCP) is measured using electrons emitted by a vacuum photodiode excited by a 266 nm Ti-sapphire femtosecond laser. The photoelectrons emitted from the photocathode are focused on a specific location of the MCP by a magnetic lens. While exist an enough voltage difference between the two ends of MCP, the energy distribution curve of output electrons form MCP can be obtained by analyzing the data as function of the bias voltage applied to the charge collector. The result shows that the energy distribution curve obtained by this means consists of a sharp and a long tail when using pulse light source. The most probable electron energy (MPE) is 12.64 eV and the full width at half maximum (FWHM) of the energy distribution curve is about 29.23 eV while the applied voltage difference is 700 V in the experimental setup. The MPE is 10.63 eV and the FWHM of the energy distribution is 22.436 eV in simulation. The measured curve is consistent with the expectation from simulation.

11 October 2021 in IEEE Access
Verified
Journal Article
Open access
DWDong Wang
Dong Wang
HCHouzhi Cai
Houzhi Cai
OYOu Yang
Ou Yang
Based on high efficiency and wide spectral splitter film and Fresnel lens, we have theoretically investigated a full solar-spectrum power-generation system. Designed nano-multilayers are fabricated on Fresnel lens. Then short wavelengths (400 nm ~ 1100 nm) of solar-spectrum can be transmitted 95% to the solar cell, and long wavelengths (1100 nm ~ 2500 nm) of solar-spectrum can be reflected 90% and focused to the thermoelectric cell. This system can combine the efficiency of solar cells and thermoelectric cells to generate electricity across the entire solar spectrum. In theory, the limit for total conversion efficiency is η = 56.64%.


20 October 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
KLKaixuan Lin
Kaixuan Lin
QLQiuyan Luo
Qiuyan Luo
JCJiajie Chen
Jiajie Chen
JWJiaheng Wang
Jiaheng Wang
JHJunkun Huang
Junkun Huang
HCHouzhi Cai
Houzhi Cai
The temporal resolution uniformity of a time-dilation framing camera is studied, and the ideal photocathode (PC) pulse curve is determined, while the temporal magnification factor is kept constant. To obtain the ideal curve, a series of linear pulses with the same slope are superposed. The variance in the temporal resolution and the number of linear pulses required are compared, while the superposition results with different slopes are used as the PC voltage. As the slope of the linear pulses decreases, the variance decreases, which means that the uniformity of the temporal resolution is improved, but the number of linear pulses required increases. In this study, linear pulses with a slope of 1 V/ps are superposed. Nine linear pulses with a front edge time of 200 ps, amplitude of 200 V, and flat top time of 1 ns are superimposed to approximate the ideal PC pulse curve with a constant temporal magnification factor of 10; the trigger times of the pulses are 0, 0, 0, 185, 200, 350, 450, 605, and 790 ps. When the superposition result is applied as the PC voltage and the measured signal is synchronized to the PC pulse at 128 ps–1 ns, the temporal resolution error is within 5%.