Arani Roy

Arani Roy

Auto-generated profile, based on publicly available information

Arani Roy

Center for Magnetic Resonance Research (CMRR), University of Minnesota, MN 55455, United States

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
ARArani Roy
Arani Roy
SWShen Wang
Shen Wang
BMBenyamin Meschede-Krasa
Benyamin Meschede-Krasa
JBJordan Breffle
Jordan Breffle
SHStephen D. Van Hooser
Stephen D. Van Hooser
While early experience with moving stimuli is necessary for the development of direction selectivity in visual cortex of carnivores, it is unclear whether experience exerts a permissive or instructive influence. To test if the specific parameters of the experienced stimuli could instructively sculpt the emergent responses, visually naive ferrets were exposed to several hours of experience with unusual spatiotemporal patterns. In the most immature ferrets, cortical neurons developed selectivity to these patterns, indicating an instructive influence. In animals that were 1–10 days more mature, exposure to the same patterns led to a developmentally-typical increase in direction selectivity. We conclude that visual development progresses via an early phase of instructive plasticity, when the specific patterns of neural activity shape the specific parameters of the emerging response properties, followed by a late phase of permissive maturation, when sensory-driven activity merely serves to enhance the response properties already seeded in cortical circuits.

7 February 2022 in NeuroImage
Verified
Journal Article
Open access
SCShinho Cho
Shinho Cho
ARArani Roy
Arani Roy
CLChao Liu
Chao Liu
DIDjaudat Sh Idiyatullin
Djaudat Sh Idiyatullin
WZWei Zhu
Wei Zhu
KUKâmil Uğurbil
Kâmil Uğurbil
The mammalian neocortex exhibits a stereotypical laminar organization, with feedforward inputs arriving primarily into layer 4, local computations shaping response selectivity in layers 2/3, and outputs to other brain areas emanating via layers 2/3, 5 and 6. It cannot be assumed a priori that these signatures of laminar differences in neuronal circuitry are reflected in hemodynamic signals that form the basis of functional magnetic resonance imaging (fMRI). Indeed, optical imaging of single-vessel functional responses has highlighted the potential limits of using vascular signals as surrogates for mapping the selectivity of neural responses. Therefore, before fMRI can be employed as an effective tool for studying critical aspects of laminar processing, validation with single-vessel resolution is needed. The primary visual cortex (V1) in cats, with its precise neuronal functional micro-architecture, offers an ideal model system to examine laminar differences in stimulus selectivity across imaging modalities. Here we used cerebral blood volume weighted (wCBV) fMRI to examine if layer-specific orientation-selective responses could be detected in cat V1. We found orientation preference maps organized tangential to the cortical surface that typically extended across depth in a columnar fashion. We then examined arterial dilation and blood velocity responses to identical visual stimuli by using two- and three-photon optical imaging at single-vessel resolution—which provides a measure of the hemodynamic signals with the highest spatial resolution. Both fMRI and optical imaging revealed a consistent laminar response pattern in which orientation selectivity in cortical layer 4 was significantly lower compared to layer 2/3. This systematic change in selectivity across cortical layers has a clear underpinning in neural circuitry, particularly when comparing layer 4 to other cortical layers.

6 March 2021 in Neurophotonics
Verified
Journal Article
Open access
PDF file
Deano Michael-Angelo FarinellaDeano Michael-Angelo Farinella
Deano Michael-Angelo Farinella
ARArani Roy
Arani Roy
CLChao Liu
Chao Liu
PKPrakash Kara
Prakash Kara
Significance: Three-photon excitation microscopy has double-to-triple the penetration depth in biological tissue over two-photon imaging and thus has the potential to revolutionize the visualization of biological processes in vivo. However, unlike the plug-and-play operation and performance of lasers used in two-photon imaging, three-photon microscopy presents new technological challenges that require a closer look at the fidelity of laser pulses. Aim: We implemented state-of-the-art pulse measurements and developed innovative techniques for examining the performance of lasers used in three-photon microscopy. We then demonstrated how these techniques can be used to provide precise measurements of pulse shape, pulse energy, and pulse-to-pulse intensity variability, all of which ultimately impact imaging. Approach: We built inexpensive tools, e.g., a second harmonic generation frequency-resolved optical gating (SHG-FROG) device and a deep-memory diode imaging (DMDI) apparatus to examine laser pulse fidelity. Results: First, SHG-FROG revealed very large third-order dispersion (TOD). This extent of phase distortion prevents the efficient temporal compression of laser pulses to their theoretical limit. Furthermore, TOD cannot be quantified when using a conventional method of obtaining the laser pulse duration, e.g., when using an autocorrelator. Finally, DMDI showed the effectiveness of detecting pulse-to-pulse intensity fluctuations on timescales relevant to three-photon imaging, which were otherwise not captured using conventional instruments and statistics. Conclusions: The distortion of individual laser pulses caused by TOD poses significant challenges to three-photon imaging by preventing effective compression of laser pulses and decreasing the efficiency of nonlinear excitation. Moreover, an acceptably low pulse-to-pulse amplitude variability should not be assumed. Particularly for low repetition rate laser sources used in three-photon microscopy, pulse-to-pulse variability also degrades image quality. If three-photon imaging is to become mainstream, our diagnostics may be used by laser manufacturers to improve system design and by end-users to validate the performance of their current and future imaging systems.

10 September 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
Deano Michael-Angelo FarinellaDeano Michael-Angelo Farinella
Deano Michael-Angelo Farinella
ARArani Roy
Arani Roy
CLChao Liu
Chao Liu
PKPrakash Kara
Prakash Kara
Significance: Three-photon excitation microscopy has double-to-triple the penetration depth in biological tissue over two-photon imaging and thus has the potential to revolutionize the visualization of biological processes in vivo . However, unlike the ‘plug-and-play’ operation and performance of lasers used in two-photon imaging, three-photon microscopy presents new technological challenges that require a closer look at the fidelity of laser pulses. Aim: We implemented state-of-the-art pulse measurements and developed new techniques for examining the performance of lasers used in three-photon microscopy. We then demonstrated how these techniques can be used to provide precise measurements of pulse shape, pulse energy and pulse-to-pulse intensity variability, all of which ultimately impact imaging. Approach: We built inexpensive tools, e.g., a second harmonic generation frequency resolved optical gating (SHG-FROG) device, and a deep-memory diode imaging (DMDI) apparatus, to examine laser pulse fidelity. Results: First, SHG-FROG revealed very large third order dispersion (TOD). This extent of phase distortion prevents the efficient temporal compression of laser pulses to their theoretical limit. Furthermore, TOD cannot be quantified when using a conventional method of obtaining the laser pulse duration, e.g., when using an autocorrelator. Finally, DMDI showed the effectiveness of detecting pulse-to-pulse intensity fluctuations on timescales relevant to three-photon imaging, which were otherwise not captured using conventional instruments and statistics. Conclusions: The distortion of individual laser pulses caused by TOD poses significant challenges to three-photon imaging by preventing effective compression of laser pulses and decreasing the efficiency of nonlinear excitation. Moreover, an acceptably low pulse-to-pulse amplitude variability should not be assumed. Particularly for low repetition rate laser sources used in three-photon microscopy, pulse-to-pulse variability also degrades image quality. If three-photon imaging is to become mainstream, our diagnostics may be used by laser manufacturers to improve system design and by end-users to validate the performance of their current and future imaging systems.