Ravi Reddy

Ravi Reddy

Auto-generated profile, based on publicly available information

Ravi Reddy

Pulmonary and Critical Care, Oregon Health and Science University, Portland, OR, United States

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
RRRavi Kondama Reddy
Ravi Kondama Reddy
RPRubin Pooni
Rubin Pooni
DZDessi Zaharieva
Dessi Zaharieva
BSBrian Senf
Brian Senf
JYJoseph El Youssef
Joseph El Youssef
PJPeter Jacobs
Peter Jacobs
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings, including more recently in medical applications. The use of real time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady state aerobic exercise. Objective: The objective of this study was to validate the accuracy of both HR and EE for two common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. Methods: We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2TM, Garmin vívosmart® HR+) during dynamic activities. Over a two-day period, 20 healthy adults (age: 27.5 ± 6.0 yrs; BMI: 22.5 ± 2.3 kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using a HR chest strap (Polar®) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. Results: Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high intensity activities, when there was a lack of repetitive wrist motion, and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (%RE) of -3.3% ± 16.7 while Fitbit estimated HR with a %RE of -4.7% ± 19.6 across all activities. The highest error was observed during high intensity intervals on bike (Fitbit: -11.4% ± 35.7; Garmin: -14.3% ± 20.5) and lowest error during high intensity intervals on treadmill (Fitbit: -1.7% ± 11.5; Garmin: -0.5% ± 9.4). Fitbit and Garmin EE estimates differed significantly with Garmin having less negative bias (Fitbit: -19.3% ± 29.9, Garmin: -1.6% ± 30.6, P<.001) across all activities, with both correlating poorly with indirect calorimetry measures. Conclusions: Two common wrist-worn devices show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.

23 June 2016 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Closed access
PDF file
PJPeter Jacobs
Peter Jacobs
JYJ. El Youssef
J. El Youssef
RRR. Reddy
R. Reddy
NRN. Resalat
N. Resalat
DBD. Branigan
D. Branigan
JCJ.R. Castle
J.R. Castle

5 October 2015 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
PJPeter Jacobs
Peter Jacobs
NRNavid Resalat
Navid Resalat
JYJoseph El Youssef
Joseph El Youssef
RRRavi Reddy
Ravi Reddy
DBDeborah Branigan
Deborah Branigan
JCJessica Castle
Jessica Castle
In this article, we present several important contributions necessary for enabling an artificial endocrine pancreas (AP) system to better respond to exercise events. First, we show how exercise can be automatically detected using body-worn accelerometer and heart rate sensors. During a 22 hour overnight inpatient study, 13 subjects with type 1 diabetes wearing a Zephyr accelerometer and heart rate monitor underwent 45 minutes of mild aerobic treadmill exercise while controlling their glucose levels using sensor-augmented pump therapy. We used the accelerometer and heart rate as inputs into a validated regression model. Using this model, we were able to detect the exercise event with a sensitivity of 97.2% and a specificity of 99.5%. Second, from this same study, we show how patients’ glucose declined during the exercise event and we present results from in silico modeling that demonstrate how including an exercise model in the glucoregulatory model improves the estimation of the drop in glucose during exercise. Last, we present an exercise dosing adjustment algorithm and describe parameter tuning and performance using an in silico glucoregulatory model during an exercise event.

1 August 2019 in Canadian Journal of Diabetes
Verified
Journal Article
Closed access
RRRavi Reddy
Ravi Reddy
AWAmanda Wittenberg
Amanda Wittenberg
JCJessica R. Castle
Jessica R. Castle
JYJoseph El Youssef
Joseph El Youssef
KWKerri Winters-Stone
Kerri Winters-Stone
PJPeter Jacobs
Peter Jacobs

18 July 2017 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Closed access
PDF file
RRRavi Reddy
Ravi Reddy
JYJoseph El Youssef
Joseph El Youssef
KWKerri Winters‐Stone
Kerri Winters‐Stone
DBDeborah Branigan Ba
Deborah Branigan Ba
JLJoseph Leitschuh
Joseph Leitschuh
PJPeter Jacobs
Peter Jacobs

4 September 2015 in Diabetes Care
Verified
Journal Article
Open access
PDF file
JCJessica R. Castle
Jessica R. Castle
JYJoseph El Youssef
Joseph El Youssef
PBParkash A. Bakhtiani
Parkash A. Bakhtiani
YCYu Cai
Yu Cai
JSJade M. Stobbe
Jade M. Stobbe
WWW. Kenneth Ward
W. Kenneth Ward
OBJECTIVE To evaluate subjects with type 1 diabetes for hepatic glycogen depletion after repeated doses of glucagon, simulating delivery in a bihormonal closed-loop system. RESEARCH DESIGN AND METHODS Eleven adult subjects with type 1 diabetes participated. Subjects underwent estimation of hepatic glycogen using 13C MRS. MRS was performed at the following four time points: fasting and after a meal at baseline, and fasting and after a meal after eight doses of subcutaneously administered glucagon at a dose of 2 µg/kg, for a total mean dose of 1,126 µg over 16 h. The primary and secondary end points were, respectively, estimated hepatic glycogen by MRS and incremental area under the glucose curve for a 90-min interval after glucagon administration. RESULTS In the eight subjects with complete data sets, estimated glycogen stores were similar at baseline and after repeated glucagon doses. In the fasting state, glycogen averaged 21 ± 3 g/L before glucagon administration and 25 ± 4 g/L after glucagon administration (mean ± SEM, P = NS). In the fed state, glycogen averaged 40 ± 2 g/L before glucagon administration and 34 ± 4 g/L after glucagon administration (P = NS). With the use of an insulin action model, the rise in glucose after the last dose of glucagon was comparable to the rise after the first dose, as measured by the 90-min incremental area under the glucose curve. CONCLUSIONS In adult subjects with well-controlled type 1 diabetes (mean A1C 7.2%), glycogen stores and the hyperglycemic response to glucagon administration are maintained even after receiving multiple doses of glucagon. This finding supports the safety of repeated glucagon delivery in the setting of a bihormonal closed-loop system.