Eric Mathew Schrauben

Eric Mathew Schrauben

Auto-generated profile, based on publicly available information

Eric Mathew Schrauben

Department of Radiology and Nuclear Medicine, Amsterdam UMC University of Amsterdam Amsterdam the Netherlands

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
MLMichael Loecher
Michael Loecher
ESEric Schrauben
Eric Schrauben
KJKevin M. Johnson
Kevin M. Johnson
OWOliver Wieben
Oliver Wieben

26 January 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ENElizabeth J. Nett
Elizabeth J. Nett
KJKevin M. Johnson
Kevin M. Johnson
AFAlex Frydrychowicz
Alex Frydrychowicz
ARAlejandro Munoz Del Rio
Alejandro Munoz Del Rio
ESEric Schrauben
Eric Schrauben
OWOliver Wieben
Oliver Wieben
Purpose: To validate a novel approach for accelerated four‐dimensional phase contrast MR imaging (4D PC‐MRI) with an extended range of velocity sensitivity.Materials and Methods: 4D PC‐MRI data were acquired with a radially undersampled trajectory (PC‐VIPR). A dual Venc (dVenc) processing algorithm was implemented to investigate the potential for scan time savings while providing an improved velocity‐to‐noise ratio. Flow and velocity measurements were compared with a flow pump, conventional 2D PC MR, and single Venc 4D PC‐MRI in the chest of 10 volunteers.Results: Phantom measurements showed excellent agreement between accelerated dVenc 4D PC‐MRI and the pump flow rate (R2 ≥ 0.97) with a three‐fold increase in measured velocity‐to‐noise ratio (VNR) and a 5% increase in scan time. In volunteers, reasonable agreement was found when combining 100% of data acquired with Venc = 80 cm/s and 25% of the high Venc data, providing the VNR of a 80 cm/s acquisition with a wider velocity range of 160 cm/s at the expense of a 25% longer scan.Conclusion: Accelerated dual Venc 4D PC‐MRI was demonstrated in vitro and in vivo. This acquisition scheme is well suited for vascular territories with wide ranges of flow velocities such as congenital heart disease, the hepatic vasculature, and others. J. Magn. Reson. Imaging 2012;35:1462–1471.

2 April 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
ESEric Schrauben
Eric Schrauben
AWAnders Wåhlin
Anders Wåhlin
KAKhalid Ambarki
Khalid Ambarki
ESErik Spaak
Erik Spaak
JMJan Malm
Jan Malm
AEAnders Eklund
Anders Eklund

21 January 2019 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ESEric M. Schrauben
Eric M. Schrauben
BSBrahmdeep Singh Saini
Brahmdeep Singh Saini
JDJack R. T. Darby
Jack R. T. Darby
JSJia Yin Soo
Jia Yin Soo
MLMitchell C Lock
Mitchell C Lock
CMChristopher K. Macgowan
Christopher K. Macgowan
To date it has not been possible to obtain a comprehensive 3D assessment of fetal hemodynamics because of the technical challenges inherent in imaging small cardiac structures, movement of the fetus during data acquisition, and the difficulty of fusing data from multiple cardiac cycles when a cardiac gating signal is absent. Here we propose the combination of volumetric velocity-sensitive cardiovascular magnetic resonance imaging (“4D flow” CMR) and a specialized animal preparation (catheters to monitor fetal heart rate, anesthesia to immobilize mother and fetus) to examine fetal sheep cardiac hemodynamics in utero. Ten pregnant Merino sheep underwent surgery to implant arterial catheters in the target fetuses. Anesthetized ewes underwent 4D flow CMR with acquisition at 3 T for fetal whole-heart coverage with 1.2–1.5 mm spatial resolution and 45–62 ms temporal resolution. Flow was measured in the heart and major vessels, and particle traces were used to visualize circulatory patterns in fetal cardiovascular shunts. Conservation of mass was used to test internal 4D flow consistency, and comparison to standard 2D phase contrast (PC) CMR was performed for validation. Streaming of blood from the ductus venosus through the foramen ovale was visualized. Flow waveforms in the major thoracic vessels and shunts displayed normal arterial and venous patterns. Combined ventricular output (CVO) was 546 mL/min per kg, and the distribution of flows (%CVO) were comparable to values obtained using other methods. Internal 4D flow consistency across 23 measurement locations was established with differences of 14.2 ± 12.1%. Compared with 2D PC CMR, 4D flow showed a strong correlation (R2 = 0.85) but underestimated flow (bias = − 21.88 mL/min per kg, p < 0.05). The combination of fetal surgical preparation and 4D flow CMR enables characterization and quantification of complex flow patterns in utero. Visualized streaming of blood through normal physiological shunts confirms the complex mechanism of substrate delivery to the fetal heart and brain. Besides offering insight into normal physiology, this technology has the potential to qualitatively characterize complex flow patterns in congenital heart disease phenotypes in a large animal model, which can support the development of new interventions to improve outcomes in this population.

17 July 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
LZLiang Zhong
Liang Zhong
ESEric M. Schrauben
Eric M. Schrauben
JGJulio Garcia
Julio Garcia
SUSergio Uribe
Sergio Uribe
SGStuart M Grieve
Stuart M Grieve
TETino Ebbers
Tino Ebbers

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
DGDatta Singh Goolaub
Datta Singh Goolaub
CRChristopher W. Roy
Christopher W. Roy
ESEric Schrauben
Eric Schrauben
DSDafna Sussman
Dafna Sussman
DMDavide Marini
Davide Marini
CMChristopher K. Macgowan
Christopher K. Macgowan
To image multidimensional flow in fetuses using golden-angle radial phase contrast cardiovascular magnetic resonance (PC-CMR) with motion correction and retrospective gating. A novel PC-CMR method was developed using an ungated golden-angle radial acquisition with continuously incremented velocity encoding. Healthy subjects (n = 5, 27 ± 3 years, males) and pregnant females (n = 5, 34 ± 2 weeks gestation) were imaged at 3 T using the proposed sequence. Real-time reconstructions were first performed for retrospective motion correction and cardiac gating (using metric optimized gating, MOG). CINE reconstructions of multidimensional flow were then performed using the corrected and gated data. In adults, flows obtained using the proposed method agreed strongly with those obtained using a conventionally gated Cartesian acquisition. Across the five adults, bias and limits of agreement were − 1.0 cm/s and [− 5.1, 3.2] cm/s for mean velocities and − 1.1 cm/s and [− 6.5, 4.3] cm/s for peak velocities. Temporal correlation between corresponding waveforms was also high (R~ 0.98). Calculated timing errors between MOG and pulse-gating RR intervals were low (~ 20 ms). First insights into multidimensional fetal blood flows were achieved. Inter-subject consistency in fetal descending aortic flows (n = 3) was strong with an average velocity of 27.1 ± 0.4 cm/s, peak systolic velocity of 70.0 ± 1.8 cm/s and an intra-class correlation coefficient of 0.95 between the velocity waveforms. In one fetal case, high flow waveform reproducibility was demonstrated in the ascending aorta (R = 0.97) and main pulmonary artery (R = 0.99). Multidimensional PC-CMR of fetal flow was developed and validated, incorporating retrospective motion compensation and cardiac gating. Using this method, the first quantification and visualization of multidimensional fetal blood flow was achieved using CMR.