Elizabeth J. Nett

Elizabeth J. Nett

Auto-generated profile, based on publicly available information

Elizabeth J. Nett

Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ENElizabeth J. Nett
Elizabeth J. Nett
KJKevin M. Johnson
Kevin M. Johnson
AFAlex Frydrychowicz
Alex Frydrychowicz
ARAlejandro Munoz Del Rio
Alejandro Munoz Del Rio
ESEric Schrauben
Eric Schrauben
OWOliver Wieben
Oliver Wieben
Purpose: To validate a novel approach for accelerated four‐dimensional phase contrast MR imaging (4D PC‐MRI) with an extended range of velocity sensitivity.Materials and Methods: 4D PC‐MRI data were acquired with a radially undersampled trajectory (PC‐VIPR). A dual Venc (dVenc) processing algorithm was implemented to investigate the potential for scan time savings while providing an improved velocity‐to‐noise ratio. Flow and velocity measurements were compared with a flow pump, conventional 2D PC MR, and single Venc 4D PC‐MRI in the chest of 10 volunteers.Results: Phantom measurements showed excellent agreement between accelerated dVenc 4D PC‐MRI and the pump flow rate (R2 ≥ 0.97) with a three‐fold increase in measured velocity‐to‐noise ratio (VNR) and a 5% increase in scan time. In volunteers, reasonable agreement was found when combining 100% of data acquired with Venc = 80 cm/s and 25% of the high Venc data, providing the VNR of a 80 cm/s acquisition with a wider velocity range of 160 cm/s at the expense of a 25% longer scan.Conclusion: Accelerated dual Venc 4D PC‐MRI was demonstrated in vitro and in vivo. This acquisition scheme is well suited for vascular territories with wide ranges of flow velocities such as congenital heart disease, the hepatic vasculature, and others. J. Magn. Reson. Imaging 2012;35:1462–1471.

15 May 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ENElizabeth J. Nett
Elizabeth J. Nett
KJKevin M. Johnson
Kevin M. Johnson
AFAlex Frydrychowicz
Alex Frydrychowicz
ARAlejandro Munoz Del Rio
Alejandro Munoz Del Rio
ESEric Schrauben
Eric Schrauben
OWOliver Wieben
Oliver Wieben
Purpose: To validate a novel approach for accelerated four‐dimensional phase contrast MR imaging (4D PC‐MRI) with an extended range of velocity sensitivity.Materials and Methods: 4D PC‐MRI data were acquired with a radially undersampled trajectory (PC‐VIPR). A dual Venc (dVenc) processing algorithm was implemented to investigate the potential for scan time savings while providing an improved velocity‐to‐noise ratio. Flow and velocity measurements were compared with a flow pump, conventional 2D PC MR, and single Venc 4D PC‐MRI in the chest of 10 volunteers.Results: Phantom measurements showed excellent agreement between accelerated dVenc 4D PC‐MRI and the pump flow rate (R2 ≥ 0.97) with a three‐fold increase in measured velocity‐to‐noise ratio (VNR) and a 5% increase in scan time. In volunteers, reasonable agreement was found when combining 100% of data acquired with Venc = 80 cm/s and 25% of the high Venc data, providing the VNR of a 80 cm/s acquisition with a wider velocity range of 160 cm/s at the expense of a 25% longer scan.Conclusion: Accelerated dual Venc 4D PC‐MRI was demonstrated in vitro and in vivo. This acquisition scheme is well suited for vascular territories with wide ranges of flow velocities such as congenital heart disease, the hepatic vasculature, and others. J. Magn. Reson. Imaging 2012.