Zhenkun Li

Zhenkun Li

Auto-generated profile, based on publicly available information

Zhenkun Li

Department of Electrical Engineering, Offshore Wind Energy Research Institute, Shanghai University of Electric Power, Shanghai, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YFYang Fu
Yang Fu
ZZZhiquan Zhang
Zhiquan Zhang
ZLZhenkun Li
Zhenkun Li
YMyang mi
yang mi
This paper presents a novel coordinated energy management approach for hybrid AC/DC distribution system with microgrid clusters considering multiple market players, which is modeled as a bi-level optimization problem by using non-cooperative game theory and robust optimization. The hybrid AC/DC distribution network and each microgrid are regarded as different entities, which are in the upper/lower level of the model, respectively. Considering the uncertainty of renewable energy, two-stage robust optimization is added in the bi-level optimization problem to suppress the influence of uncertainty on power interaction and achieve the minimum operation costs of each entity under uncertainty. Furthermore, In the upper level model, hybrid AC/DC distribution network can control power flow in real time, promote power interaction between entities, and reduce operation cost under uncertainty by using effective control of converter station and diesel generator. And each microgrid has dealt with the impact of uncertainty on the power interaction by reasonably managing the charge/discharge of energy storage, which realizes its own minimum operation cost. The proposed model can be transformed into mathematical programming with complementarity constraints (MPCC) by using Karush-Kuhn-Tucker conditions. Finally, numerical cases on an improved IEEE 33-bus hybrid AC/DC distribution system show the effectiveness of the proposed method.

30 November 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YFYang Fu
Yang Fu
ZZZhiquan Zhang
Zhiquan Zhang
YMyang mi
yang mi
ZLZhenkun Li
Zhenkun Li
FLFangxing Li
Fangxing Li

18 September 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LJLiang Ji
Liang Ji
JSJiabin Shi
Jiabin Shi
QHQiteng Hong
Qiteng Hong
YFYang Fu
Yang Fu
XCXiao Chang
Xiao Chang
CBCampbell Booth
Campbell Booth
This paper presents a new multi-objective control strategy for inverter-interfaced distributed generation (IIDG) to ensure its safe and continuous operation under unbalanced voltage sags. The proposed control strategy can effectively improve the low voltage ride through (LVRT) capability, reduce active power oscillations, and limit overcurrent simultaneously, which are marked as the most important control objectives of IIDG during unbalanced voltage sags. The advanced voltage support scheme, which utilizes positive sequence component, is firstly proposed to maximize the LVRT capability of IIDG during unbalanced voltage sags. Then, to ensure the safety of IIDG, the active power oscillation suppression and current limitation algorithm are designed individually. Based on the control algorithms of such objectives, the multi-objective control method, including scenario classification and reference current determination, is then presented to achieve such three objectives under various system conditions simultaneously. Finally, case studies and evaluations based on MATLAB/Simulink are carried out to illustrate the effectiveness of the proposed method.

19 February 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ZLZhenkun Li
Zhenkun Li
ZWZhifeng Wang
Zhifeng Wang
YFYang Fu
Yang Fu
NZNan Zhao
Nan Zhao
Integrated energy system (IES) is an effective solution for energy and environment problems. In view of the difficulty of traditional reliability assessment methods to reasonably and effectively assess the reliability of the IES, an energy supply reliability assessment method based on sequential Monte Carlo simulation is proposed in this study. The optimal operation of the system is realised by mobilising the multi‐energy complementary characteristics during device failure. The reliability of the system under three different operation objectives is compared and analysed. Three new reliability indices are proposed, which take into account the supply of multiple energy loads and the differences among different energy. Finally, through the analysis of energy supply reliability under different objectives, the reasonability of the proposed indices and the flexible scheduling of energy flow under different objectives are verified; therefore, the IES can realise adaptive and targeted operation strategy during device failure. Also, the influence of different device faults on the system's energy supply reliability is ranked, which is of great significance to find the weak parts of the system and provide a reference for the system to improve energy supply reliability.

9 December 2024 in Energy
Verified
Journal Article
Closed access
YFYang Fu
Yang Fu
JSJie Shan
Jie Shan
ZLZhenkun Li
Zhenkun Li
BXBoLin Xie
BoLin Xie
JPJeng-Shyang Pan
Jeng-Shyang Pan

15 June 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
YWYu Wang
Yu Wang
LJLiang Ji
Liang Ji
YDYifan Ding
Yifan Ding
XCXiao Chang
Xiao Chang
QHQiteng Hong
Qiteng Hong
XYXingwu Yang
Xingwu Yang
The virtual synchronous generator (VSG) is a good solution for stabilizing the power system with high penetration of renewable energy. However, in case of serious unbalanced voltage disturbance/fault, the conventional VSG may lose voltage, inertia, and damping support characteristics to the grid and even can cause disconnection of renewable energy. This paper proposes an improved fault control strategy for VSG with the coordination of STATCOM. The proposed method can provide sufficient voltage support while keeping continuous system inertia and damping support under severe unbalanced fault. In the paper, an improved VSG and STATCOM control topology based on positive and negative sequence current control are first proposed so as to keep the damping and inertia support to grid during the grid fault. Secondly, the voltage support control method for the VSG with improved topology during unbalanced fault is introduced, which can achieve multiple control objectives, in terms of voltage support, current limitation, and active power output simultaneously. Then a coordination control scheme of improved VSG and STATCOM is developed so as to optimize the maximum control objectives in all possible scenarios, especially in the case of severe unbalanced fault. Finally, the effectiveness of the method is verified by using the MATLAB/SIMULINK simulation platform.