The low-lying isomeric state of provides unique opportunities for high-resolution laser spectroscopy of the atomic nucleus. We determine the energy of this isomeric state by taking the absolute energy difference between the excitation energy required to populate the 29.2-keV state from the ground state and the energy emitted in its decay to the isomeric excited state. A transition-edge sensor microcalorimeter was used to measure the absolute energy of the 29.2-keV ray. Together with the cross-band transition energy () and the branching ratio of the 29.2-keV state measured in a recent study, the isomer energy was determined to be . Our result is in agreement with the latest measurements based on different experimental techniques, which further confirms that the isomeric state of is in the laser-accessible vacuum ultraviolet range.
We present a detailed analysis of Chandra X-ray observations of the lensing cluster of galaxies Cl 0024+17 at z = 0.395. We found that the radial temperature profile is consistent with being isothermal out to ~600 kpc and that the average X-ray temperature is 4.47 keV. The X-ray surface brightness profile is represented by the sum of extended emission centered at the central bright elliptical galaxy with a small core of 50 kpc and more extended emission that can be well described by a spherical β-model with a core radius of about 210 kpc. Assuming the X-ray-emitting gas to be in hydrostatic equilibrium, we estimated the X-ray mass within the arc radius and found that it is significantly smaller than the strong lensing mass by a factor of about 2-3. We detected a strong redshifted iron K line in the X-ray spectrum from the cluster for the first time and found the metal abundance to be 0.76 solar.
We present results from Chandra observations of SDSS J1004+4112, a strongly lensed quasar system with a maximum image separation of 15''. All four bright images of the quasar, as well as resolved X-ray emission originating from the lensing cluster, are clearly detected. The emission from the lensing cluster extends out to approximately 15. We measure the bolometric X-ray luminosity and temperature of the lensing cluster to be 4.7 × 1044 ergs s-1 and 6.4 keV, consistent with the luminosity-temperature relation for distant clusters. The mass estimated from the X-ray observation shows excellent agreement with the mass derived from gravitational lensing. The X-ray flux ratios of the quasar images differ markedly from the optical flux ratios, and the combined X-ray spectrum of the images possesses an unusually strong Fe Kα emission line, both of which are indicative of microlensing.
We searched for absorption lines of highly ionized O and Ne in the energy spectra of two Low-mass X-ray binaries, 4U1820-303 in the globular cluster NGC6624 and Cyg X-2, observed with the Chandra LETG, and detected O VII, O VIII and Ne IX absorption lines for 4U1820-303. The equivalent width of the O VII K alpha line was 1.19 +0.47/-0.30 eV (90 % errors) and the significance was 6.5 sigma. Absorption lines were not detected for Cyg X-2 with a 90 % upper limit on the equivalent width of 1.06 eV for O VII K alpha. The absorption lines observed in 4U1820-303 are likely due to hot interstellar medium, because O will be fully photo-ionized if the absorbing column is located close to the binary system. The velocity dispersion is restricted to b = 200 - 420 km/s from consistency between O VII K alpha and K beta lines, Ne/O abundance ratio, and H column density. The average temperature and the O VII density are respectively estimated to be log(T[K]) = 6.2 - 6.3 and n(OVII) = (0.7 - 2.3) x 10^{-6} cm^{-3}. The difference of O VII column densities for the two sources may be connected to the enhancement of the soft X-ray background (SXB) towards the Galactic bulge region. Using the polytrope model of hot gas to account for the SXB we corrected for the density gradient and estimated the midplane O VII density at the solar neighborhood. The scale height of hot gas is then estimated using the AGN absorption lines. It is suggested that a significant portion of both the AGN absorption lines and the high-latitude SXB emission lines can be explained by the hot gas in our Galaxy.Comment: Accepted for publication in ApJ. 7 pages, 9 eps figure
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.