Christian Hedeager Krag

Christian Hedeager Krag

Auto-generated profile, based on publicly available information

Christian Hedeager Krag

Department of Radiology, University Hospital Copenhagen-Herlev and Gentofte, Copenhagen, Denmark

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
CKChristian H. Krag
Christian H. Krag
FMFelix C. Müller
Felix C. Müller
KGKaren L. Gandrup
Karen L. Gandrup
HRHenriette Raaschou
Henriette Raaschou
MAMichael B. Andersen
Michael B. Andersen
MBMikael Boesen
Mikael Boesen

1 August 2024 in Radiology
Verified
Journal Article
Closed access
LPLouis Lind Plesner
Louis Lind Plesner
FMFelix C. Müller
Felix C. Müller
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
CKChristian Hedeager Krag
Christian Hedeager Krag
LLLene C. Laustrup
Lene C. Laustrup
MAMichael Brun Andersen
Michael Brun Andersen
A commercial AI tool used off-label correctly excluded pathology in 24.5%–52.7% of unremarkable chest radiographs at greater than or equal to 98% sensitivity, with lower rates of critical misses than radiology reports.

8 May 2025 in European Journal of Radiology
Verified
Journal Article
Open access
CKChristian Hedeager Krag
Christian Hedeager Krag
FMFelix Christoph Müller
Felix Christoph Müller
KGKaren Lind Gandrup
Karen Lind Gandrup
LPLouis Lind Plesner
Louis Lind Plesner
MSMalini Vendela Sagar
Malini Vendela Sagar
MBMikael Boesen
Mikael Boesen
To evaluate spectrum bias in stroke MRI analysis by excluding cases with uncertain acute ischemic lesions (AIL) and examining patient, imaging, and lesion factors associated with these cases. This single-center retrospective observational study included adults with brain MRIs for suspected stroke between January 2020 and April 2022. Diagnostic uncertain AIL were identified through reader disagreement or low certainty grading by a radiology resident, a neuroradiologist, and the original radiology report consisting of various neuroradiologists. A commercially available deep learning tool analyzing brain MRIs for AIL was evaluated to assess the impact of excluding uncertain cases on diagnostic odds ratios. Patient-related, MRI acquisition-related, and lesion-related factors were analyzed using the Wilcoxon rank sum test, χ2 test, and multiple logistic regression. The study was approved by the National Committee on Health Research Ethics. In 989 patients (median age 73 (IQR: 59-80), 53% female), certain AIL were found in 374 (38%), uncertain AIL in 63 (6%), and no AIL in 552 (56%). Excluding uncertain cases led to a four-fold increase in the diagnostic odds ratio (from 68 to 278), while a simulated case-control design resulted in a six-fold increase compared to the full disease spectrum (from 68 to 431). Independent factors associated with uncertain AIL were MRI artifacts, smaller lesion size, older lesion age, and infratentorial location. Excluding uncertain cases leads to a four-fold overestimation of the diagnostic odds ratio. MRI artifacts, smaller lesion size, infratentorial location, and older lesion age are associated with uncertain AIL and should be accounted for in validation studies.

17 September 2022
Verified
Book Chapter
Closed access
PDF file
PDPengfei Diao
Pengfei Diao
APAkshay Pai
Akshay Pai
CIChristian Igel
Christian Igel
CKChristian Hedeager Krag
Christian Hedeager Krag

2 October 2024 in medRxiv
Verified
Preprint
Open access
PDF file
CKChristian Hedeager Krag
Christian Hedeager Krag
TBTrine Balschmidt
Trine Balschmidt
FBFrederik Bruun
Frederik Bruun
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
JXJack Junchi Xu
Jack Junchi Xu
FMFelix Christoph Müller
Felix Christoph Müller
Introduction: We investigated if large language models (LLMs) can be used for abstract screening in systematic- and scoping reviews. Methods: Two broad reviews were designed: a systematic review structured according to the PRISMA guideline with abstract inclusion based on PICO criteria; and a scoping review, where we defined abstract characteristics and features of interest to look for. For both reviews 500 abstracts were sampled. Two readers independently screened abstracts with disagreements handled with arbitrations or consensus, which served as the reference standard. The abstracts were analysed by six LLMs (GPT-4o, GPT-4T, GPT-3.5, Claude3-Opus, Claude3-Sonnet, and Claude3-Haiku). Primary outcomes were diagnostic test accuracy measures for abstract inclusion, abstract characterisation and feature of interest detection. Secondary outcome was the degree of automation using LLMs as a function of the error rate. Results: In the systematic review 12 studies were marked as include by the human consensus. GPT-4o, GPT-4T, and Claude3-Opus achieved the highest accuracies (97% to 98%) comparable to the human readers (96% and 98%), although sensitivity was low (33% to 50%). In the scoping review 130 features of interest were present and the LLMs achieved sensitivities between 74-84%, comparable to the human readers (73% and 86%). The specificity of GPT-4o (98%) and GPT-4T (>99%) greatly surpassed the other LLMs (between 33% and 93%). For abstract characterization all LLMs achieved above 95% accuracy for language, manuscript type and study participant characterisation. For characterisation of disease-specific features only GPT-4T and GPT-4o showed very high accuracy. For abstract inclusion the highest automation rate (91%) at the lowest error rate (8%) was achieved by use of two LLMs with disagreement solved by human arbitration. An LLM pre screening before human abstract screening achieved an automation rate of 55% with no missed abstracts. Conclusion: Abstract characterisation and specific feature of interest detection with LLMs is feasible and accurate with GPT-4o and GPT-4T. The majority of abstract screenings for systematic reviews can be automated with use of LLMs, at low error rates.

15 July 2025 in European Radiology
Verified
Journal Article
Open access
PDF file
CKChristian Hedeager Krag
Christian Hedeager Krag
FMFelix Christoph Müller
Felix Christoph Müller
KGKaren Lind Gandrup
Karen Lind Gandrup
MAMichael Brun Andersen
Michael Brun Andersen
JMJakob Møllenbach Møller
Jakob Møllenbach Møller
MBMikael Ploug Boesen
Mikael Ploug Boesen
Objectives: To assess the prevalence of motion artifacts and the factors associated with them in a cohort of suspected stroke patients, and to determine their impact on diagnostic accuracy for both AI and radiologists. Materials and methods: This retrospective cross-sectional study included brain MRI scans of consecutive adult suspected stroke patients from a non-comprehensive Danish stroke center between January and April 2020. An expert neuroradiologist identified acute ischemic, hemorrhagic, and space-occupying lesions as references. Two blinded radiology residents rated MRI image quality and motion artifacts. The diagnostic accuracy of a CE-marked deep learning tool was compared to that of radiology reports. Multivariate analysis examined associations between patient characteristics and motion artifacts. Results: 775 patients (68 years ± 16, 420 female) were included. Acute ischemic, hemorrhagic, and space-occupying lesions were found in 216 (27.9%), 12 (1.5%), and 20 (2.6%). Motion artifacts were present in 57 (7.4%). Increasing age (OR per decade, 1.60; 95% CI: 1.26, 2.09; p < 0.001) and limb motor symptoms (OR, 2.36; 95% CI: 1.32, 4.20; p = 0.003) were independently associated with motion artifacts in multivariate analysis. Motion artifacts significantly reduced the accuracy of detecting hemorrhage. This reduction was greater for the AI tool (from 88 to 67%; p < 0.001) than for radiology reports (from 100 to 93%; p < 0.001). Ischemic and space-occupying lesion detection was not significantly affected. Conclusion: Motion artifacts are common in suspected stroke patients, particularly in the elderly and patients with motor symptoms, reducing accuracy for hemorrhage detection by both AI and radiologists. Key Points: Question Motion artifacts reduce the quality of MRI scans, but it is unclear which factors are associated with them and how they impact diagnostic accuracy. Findings Motion artifacts occurred in 7% of suspected stroke MRI scans, associated with higher patient age and motor symptoms, lowering hemorrhage detection by AI and radiologists. Clinical relevance Motion artifacts in stroke brain MRIs significantly reduce the diagnostic accuracy of human and AI detection of intracranial hemorrhages. Elderly patients and those with motor symptoms may benefit from a greater focus on motion artifact prevention and reduction. Graphical