18 January 2018 in Biomedical Optics Express
A laser scanning optical resolution photoacoustic microscopy (LS OR-PAM) system based on a stationary fibre optic sensor is described. The sensor comprises an optically resonant interferometric polymer cavity formed on the tip of a rounded single mode optical fibre. It provides low noise equivalent pressure (NEP = 68.7 Pa over a 20 MHz measurement bandwidth), a broad bandwidth that extends to 80 MHz and a near omnidirectional response. The latter is a significant advantage, as it allows large areas (>1cm2) to be imaged without the need for translational mechanical scanning offering the potential for fast image acquisition. The system provides a lateral resolution of 8 µm, an axial resolution of 21 µm, and a field of view up to 10 mm × 10 mm. To demonstrate the system, in vivo 3D structural images of the microvasculature of a mouse ear were obtained, showing single capillaries overlaying larger vessels as well as functional images revealing blood oxygen saturation.
1 September 2021 in APL Photonics
In this work, a novel fiber optic sensor based on Fabry–Pérot interferometry is adopted in an optical coherence photoacoustic microscopy (OC-PAM) system to enable high-resolution in vivo imaging. The complete OC-PAM system is characterized using the fiber optic sensor for photoacoustic measurement. After characterization, the performance of the system is evaluated by imaging zebrafish larvae in vivo. With a lateral resolution of 3.4 μm and an axial resolution of 3.7 μm in air, the optical coherence microscopy subsystem visualizes the anatomy of the zebrafish larvae. The photoacoustic microscopy subsystem reveals the vasculature of the zebrafish larvae with a lateral resolution of 1.9 μm and an axial resolution of 37.3 μm. As the two modalities share the same sample arm, we obtain inherently co-registered morphological and vascular images. This OC-PAM system provides comprehensive information on the anatomy and vasculature of the zebrafish larvae. Featuring compactness, broad detection bandwidth, and wide detection angle, the fiber optic sensor enables a large field of view with a static sensor position. We verified the feasibility of the fiber optic sensor for dual-modality in vivo imaging. The OC-PAM system, as a non-invasive imaging method, demonstrates its superiority in the investigation of zebrafish larvae, an animal model with increasing significance in developmental biology and disease research. This technique can also be applied for functional as well as longitudinal studies in the future.
1 March 2022 in Ultrasound in Medicine & Biology
Accurate identification of the needle tip is a key challenge with ultrasound-guided percutaneous interventions in regional anaesthesia, foetal surgery and cardiovascular medicine. In this study, we developed an ultrasonic needle tracking system in which the measured needle tip location was used to set the electronic focus of the external ultrasound imaging probe. In this system, needle tip tracking was enabled with a fibre-optic ultrasound sensor that was integrated into a needle stylet, and the A-lines recorded by the sensor were processed to generate tracking images of the needle tip. The needle tip position was estimated from the tracking images. The dependency of the tracking image on the electronic focal depth of the external ultrasound imaging probe was studied in a water bath and with needle insertions into a clinical training phantom. The variability in the estimated tracked position of the needle tip, with the needle tip at fixed depths in the imaging plane across a depth range from 0.5 to 7.5 cm, was studied. When the electronic focus was fixed, the variability of tracked position was found to increase with distance from that focus. The variability with the fixed focus was found to depend on the the relative distance between the needle tip and focal depth. It was found that with dynamic focusing, the maximum variability of tracked position was below 0.31 mm, as compared with 3.97 mm for a fixed focus.
11 August 2017 in National Science Review
Vaccines are among the most important tools used to prevent and treat infectious disease. Saving an estimated 3 million lives annually, as well as billions of dollars in treatment costs, they represent both one of mankind's great humanitarian accomplishments and one of our best investments [1,2]. Yet, in spite of their well-established track record, misinformation regarding vaccine safety and efficacy stubbornly persists. Decreased rates of immunization in many parts of the world attest to the fact that anti-vaccine campaigns and other sources of misinformation are distorting public perception of these life-saving measures [3].
27 June 2022 in Biomedical Optics Express
All-optical ultrasound (OpUS), where ultrasound is both generated and received using light, has emerged as a modality well-suited to highly miniaturised applications. In this work we present a proof-of-concept OpUS transducer built onto a single optical fibre with a highly miniaturised lateral dimension (0.4 MPa and a corresponding bandwidth >27 MHz. Concurrent ultrasound generation and reception from the transducer enabled imaging via motorised pull-back allowing image acquisition times of 4 s for an aperture of 20 mm. Image resolution was as low as ~50 µm and 190 µm in the axial and lateral extents, respectively, without the need for image reconstruction. Porcine aorta was imaged ex vivo demonstrating detailed ultrasound images. The unprecedented level of miniaturisation along with the high image quality produced by this device represents a radical new paradigm for minimally invasive imaging.