19 May 2023 in Journal of Food Composition and Analysis
9 February 2022 in IEEE Transactions on Instrumentation and Measurement
Electrostatic tomography (EST) can measure the flow parameters of the gas–solid two-phase flow based on the reconstructed charge image. The traditional image reconstruction methods cannot achieve high image quality because a lot of specific information is lost during the linearization process. Deep learning-based reconstruction methods can avoid the calculation of the linearization process. However, the prior knowledge of the relationship between boundary measurement data and the true image is rarely applied in the deep learning-based methods for EST. To solve this problem and improve the quality of reconstructed images, a novel 1-D prior knowledge-based residual network (PK-ResNet) is proposed. The whole network is divided into three parts, namely, the initial feature extraction module, the residual feature extraction module, and the image reconstruction module. The prior knowledge of EST is encapsulated as a loss function to enhance the performance of the network. The network is trained by 35 000 generated samples. Simulation and experimental results show that the correlation coefficients of the reconstructed images of PK-ResNet are larger than those of the traditional algorithms and some existing image reconstruction algorithms based on deep learning.
9 June 2022 in IEEE Transactions on Instrumentation and Measurement
Electrostatic tomography (EST) is a technology that uses the induced charge on the electrode surface to reconstruct the parameter distribution of gas–solid two-phase flow. The induced signal is dynamic, whereas the induced charge required in the image reconstruction theory is static. Therefore, it is necessary to calculate the characteristic value of the signal to characterize the induced charge before image reconstruction. However, the calculation methods of characteristic value are different at present, and there is a lack of unified understanding. For the above problem, this article analyzes the mechanism of signal induced by the charged single particle, compares the differences between the charge- and current-sensitive preamplifiers, and comes to the conclusion that the current-sensitive preamplifier is more suitable for the measurement of induced charge. By further studying the output signal of the conditioning circuit with the current-sensitive preamplifier, root mean square of charge (RMSCE) is proposed to characterize the induced charge. Simulation and experimental results show that RMSCE has stronger characterization ability for the induced charge and can be used in the EST system to obtain high-quality reconstructed images.
1 January 2013 in Journal of Mechanical Engineering