Ali Kashif

Ali Kashif

Auto-generated profile, based on publicly available information

Ali Kashif

Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RWRuizhi Wang
Ruizhi Wang
JJJun Jiang
Jun Jiang
RSRongbin Shi
Rongbin Shi
CZChaoyue Zhang
Chaoyue Zhang
AKAli Kashif
Ali Kashif
HGHaidong Gu
Haidong Gu
Optical fiber sensors (OFS) have been demonstrated to exhibit intrinsic safety and resistance to electromagnetic interference (EMI) that make them highly effective in partial discharge (PD) detection. In order to resolve the issue of output instability in traditional interferometric OFS and to reduce the sampling rate for real-time detection, the heterodyne interferometric PD detection method based on the dual-phase detectors (DPD) scheme has been proposed. By introducing high-frequency shifting in the reference arm and combining it with analog phase detection, real-time stable demodulation of ultrasonic signals is achieved. The DPD scheme reduces the system’s sampling rate to 1/2000 of the algorithm’s demodulation rate and effectively resolves the signal distortion issues occurring in the nonlinear region. For detection of PD signals in the typical model in the lab, amplitude detected by OFS is significantly higher than that of the Piezoelectric Transducer (PZT), with the signal-to-noise ratio (SNR) improvement of 3.6 dB. Regarding the PD detection of oil-immersed transformers in the field, the developed OFS based on DPD has achieved a 3.5 dB improvement in sensitivity for PD detection. The results demonstrate that the heterodyne interferometric method based on DPD holds profound potential in the field of PD detection in electrical equipment.

5 July 2023 in European Journal of Theoretical and Applied Sciences
Verified
Journal Article
Open access
PDF file
KAKashif Ali
Kashif Ali
ZRZuraiz Rana
Zuraiz Rana
ANAshfaq Niaz
Ashfaq Niaz
CLChen Liang
Chen Liang
Wind turbines are complex and expensive equipment, requiring high reliability and low maintenance costs. However, most of the existing fault tree analysis (FTA) methods for reliability analysis of wind turbines assume that the repair of wind turbines can restore them to as good as new condition, which is called perfect repair. This assumption may not be realistic in practice, as the repair may not fully recover the original performance or functionality of the equipment or may introduce new defects or errors. This phenomenon is called imperfect repair, which can reduce the reliability of wind turbines over time. To consider the imperfect repair effect in reliability analysis, we present a new FTA approach in this study. In order to predict and assess the failure intensity and dependability of wind turbines under imperfect repair, the proposed FTA technique uses a log-linear proportional intensity model (LPIM). Failure probability, failure rate, and mean time to failure can all be improved with the suggested FTA technique for wind turbines operating with poor repair. The proposed FTA method can also identify the critical components or failure modes most affected by the imperfect repair effect and suggest preventive maintenance actions to improve the reliability of wind turbines. We demonstrate the applicability and effectiveness of the proposed FTA method through a case study on a real or hypothetical wind turbine system under imperfect repair. The findings indicate that the proposed FTA method offers a more precise and authentic assessment of the reliability of wind turbines in the presence of imperfect repair, in contrast to existing FTA methods that assume perfect repair. The findings also demonstrate that the electrical system, hydraulic system, gearbox, generator, and blade are the most critical components or failure modes affecting the system's reliability.

5 July 2023 in European Journal of Theoretical and Applied Sciences
Verified
Journal Article
Open access
PDF file
ZRZuraiz Rana
Zuraiz Rana
ANAshfaq Niaz
Ashfaq Niaz
AKAli Kashif
Ali Kashif
WKWaleed Khan
Waleed Khan
INIbrar Niaz
Ibrar Niaz
RPRizwan Ali Prince
Rizwan Ali Prince
The Model Predict Control (MPC) based Intelligent Advance Metering (IAM) is a core maneuver of future smart grids (SG). SG is the advanced generation of electric power and utility system that improve operation technology (OT) and information technology (IT) to provide nonstop, self-recovery, self-configuration, low-cost, and security-based electricity to the consumer in real-time. Smart metering (SM) allows SG to connect the electric, gas, and oil utilities through sensors. Power plants, consumers, and utility companies will be received real-time wireless control IAM with fifth generation (5G) network technology. The aim of 5G network technology is to enable power grid digitalization (PGD) and facilitate the (IOT) Internet of Things for the future advance SG with benefits such as high-rate public safety, low latency, ultra-high speed, large number of connectivity, and reliability. In this paper, we analyze future predictions about energy needs by using MPC, fast self-recovery system, self-configuration, and upgradation, better performance of service provider, faster power connecting after an outage, control electric theft, minimize electric leakage, a large number of wireless connecting of IAM home-based, and real-time monitoring via human machine interface (HMI) and for customer end IAM operation over 5G networks to reduce billing price, reduce meter cost, lower outage cost, and as well as personalized control over electricity consumption and future challenge in this area.

27 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RWRuizhi Wang
Ruizhi Wang
JJJun Jiang
Jun Jiang
XWXiangyan Wu
Xiangyan Wu
AKAli Kashif
Ali Kashif
Carlos RuizCarlos Ruiz
Carlos Ruiz
Optical fiber sensors (OFS) have been demonstrated to be intrinsically safety and resistant to electromagnetic interference (EMI), making them highly effective in partial discharge (PD) detection which occurs during the operation of high-voltage power equipment. To achieve lightweight and highly sensitive detection, the OFS based on single-multi-single mode (SMS) structure has been designed and investigated for PD detection. The detection performance has been optimized through both demodulation topology and sensor probe structure. By optimizing the laser light source parameters, the detection amplitude increased by 5.65 times compared to standard broadband light. Multiple probes with different forms and lengths were wound for comparative testing, leading to the conclusion that using longer optical fibers for ultrasound signal detection can significantly improve detection sensitivity. In this regard, the 3-meter-long optical fiber was wound into a 2 cm diameter optical fiber probe and applied to the detection of a simulated oil-immersed transformer winding discharge device. The signal-to-noise ratio (SNR) was improved by 5.4 dB and 20.2 dB compared to internal and externally installed PZT(R15α), respectively. It is demonstrated that SMS type OFS shows significant potential as a novel approach for PD detection with the advantages of high sensitivity and streamlined structure.