Optical fiber distributed acoustic sensing (DAS) is a potential approach to realize on-line monitoring and rapid localization of power cable partial discharges. Distributed detection of discharges requires a DAS system with a wide frequency band and low noise level. For this purpose, an improved coherent optical time-domain reflectometry (COTDR) method based on dual-frequency probe pulses was developed. The method doubled the length-bandwidth product (LBP) of traditional DAS systems without significantly increasing the complexity of signal demodulation. A discharge signal extraction algorithm was also proposed based on the detection results of the dual-frequency pulses to exclude the effects of fading noises and vibrations. The improved COTDR system demonstrated the frequency band extension by detecting and recovering the 50 kHz sinusoidal vibration. The sensing distance was 1.1 km and the spatial resolution was 7.15 m. Afterwards, the multi-point weak spark discharge acoustic signals were correctly measured and localized, and the frequency components up to 71.36 kHz were detected. The proposed COTDR method provides a prospective solution of distributed partial discharge detection for power cables.
1 September 2023 in IEEE Transactions on Instrumentation and Measurement
To realize the highly sensitive multiple-point detection of partial discharge (PD) acoustic emission (AE) in power transformers, an ultrasonic sensing system based on a distributed feedback fiber laser (DFB-FL) array was proposed. Four DFB-FLs were connected on a single optical fiber as sensing elements to synchronously detect PD AE signals. The heterodyne coherent detection structure was formed by introducing an acousto-optic modulator (AOM) into the unbalanced Mach-Zehnder interferometer (MZI) to realize the rapid and highly sensitive demodulation of ultrasonic signals. The influence of noises and arm length difference on the lower limit of detection (LLOD) were theoretically discussed and experimentally verified. By adopting a 70-meter-long delay fiber, the proposed system performed a 9.54 dB lower average detection limit than that of PZT. Finally, based on the proposed system, a partial discharge source was accurately located in a 1000 mm×1000 mm×1100 mm oil tank, and the localization error was 24.6 mm. The proposed method exhibited promising application prospects in sensitivity, installation convenience, anti-interference and reliability.
Partial discharge (PD) ultrasonic detection is an early sign of the insolation defects of power transformers. The early diagnosis of PD requires the high sensitivity and reliability of ultrasonic sensing systems. For this purpose, a reformative PD ultrasonic sensing system based on phase-shifted FBG (PS-FBG) was demonstrated. By using PS-FBG as the ultrasonic sensing unit, the ultrasonic sensing system improved the response to the ultrasonic signal and overcame the electromagnetic noise. To compensate for the influence of temperature change on the ultrasonic sensing system, an automatic wavelength scanning demodulating method was carried out. The wavelength spanning strategy was optimized based on the principle of cross-correlation, in order to quicken the spanning. A PD detection test in the transformer oil was conducted, and the result shows that PS-FBG was 17.5 times more sensitive than PZT. Because of the better ultrasonic response, the proposed system was able to achieve the early diagnosis of insolation faults in a power transformer.
Optical fiber sensors (OFS) have been demonstrated to exhibit intrinsic safety and resistance to electromagnetic interference (EMI) that make them highly effective in partial discharge (PD) detection. In order to resolve the issue of output instability in traditional interferometric OFS and to reduce the sampling rate for real-time detection, the heterodyne interferometric PD detection method based on the dual-phase detectors (DPD) scheme has been proposed. By introducing high-frequency shifting in the reference arm and combining it with analog phase detection, real-time stable demodulation of ultrasonic signals is achieved. The DPD scheme reduces the system’s sampling rate to 1/2000 of the algorithm’s demodulation rate and effectively resolves the signal distortion issues occurring in the nonlinear region. For detection of PD signals in the typical model in the lab, amplitude detected by OFS is significantly higher than that of the Piezoelectric Transducer (PZT), with the signal-to-noise ratio (SNR) improvement of 3.6 dB. Regarding the PD detection of oil-immersed transformers in the field, the developed OFS based on DPD has achieved a 3.5 dB improvement in sensitivity for PD detection. The results demonstrate that the heterodyne interferometric method based on DPD holds profound potential in the field of PD detection in electrical equipment.
Optic fiber interferometers are highly sensitive ultrasonic sensors for partial discharge detection. However, low-frequency vibration and environmental noise will disturb the sensors in the field, and cause a phase fading suppression effect that reduces sensitivity. This paper analyzed the problems existing in the phase feedback control system based on PZT, and an improved scheme incorporating a high-frequency carrier phase demodulation is proposed. Based on an acousto-optic modulator, the proposed phase feedback control system overcomes the phase fading suppression effect. A test is carried out on an ultrasonic calibration platform and a transformer oil discharge platform. The test results show that the stability of the improved phase demodulation system has been significantly improved, and meets the requirements of field applications. Compared with the signal-to-noise ratio at the time of phase fading of the system before the improvement, the signal-to-noise ratio of the improved system is improved by 69 dB.
6 April 2023 in IEEE Transactions on Power Delivery
Pumped storage power plants (PSPPs) are among the most efficient and practical large-scale energy storage systems. In recent years, several transformer failures have occurred in PSPPs, and transient overvoltage is considered a potential reason for failure. However, there is a lack of field measurement results for transient analysis. In this paper, a switching transient measurement system and multipoint synchronous triggering system were developed. Field measurements were carried out in three PSPPs. According to the measurement results, the maximum amplitude of the switching overvoltage was 630.6±46.5 kV. The shortest front time was 76±7.6 ns. The largest steepness was 1130±140.8 kV/μs. A simulation model was built to analyze three phenomena in the transient, including multistep waveform, overvoltage peak, and power transformer demagnetization. The measurement and analysis results are beneficial for the improvement of simulation modeling. It is helpful to pinpoint potentially damaging transients for equipment manufacturers and designers of PSPPs.